Literature DB >> 9211384

Ghost artifact reduction for echo planar imaging using image phase correction.

M H Buonocore1, L Gao.   

Abstract

An algorithm is described for reducing ghost artifacts in echo planar imaging (EPI) using phase corrections derived from images reconstructed using only even or odd k-space lines. The N/2 ghost, that arises principally from time-reversal of alternate k-space lines, was significantly reduced by this algorithm without the need for a calibration scan. In images obtained in eight subjects undergoing EPI for auditory functional MRI (fMRI) experiments, N/2 ghost intensity was reduced from 10.3% +/- 2.1% (range: 7.9-14.1%) to 4.5% +/- 0.2% (range: 4.1-4.9%) of parent image intensity, corresponding to a percent reduction in ghost intensity of 54% +/- 9% (range: 43-65%), and the algorithm restored this intensity to the parent image. It provided a significant improvement in image appearance, and increased the correlation coefficients related to neural activation in functional MRI studies. The algorithm provided reduction of artifacts from all polynomial orders of spatial phase errors in both spatial directions. The algorithm did not eliminate N/2 ghost intensity contributed by field inhomogeneities, susceptibility, or chemical shift.

Mesh:

Year:  1997        PMID: 9211384     DOI: 10.1002/mrm.1910380114

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  50 in total

1.  Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan.

Authors:  V J Schmithorst; B J Dardzinski; S K Holland
Journal:  IEEE Trans Med Imaging       Date:  2001-06       Impact factor: 10.048

2.  Posterior cingulate cortex activation by emotional words: fMRI evidence from a valence decision task.

Authors:  Richard J Maddock; Amy S Garrett; Michael H Buonocore
Journal:  Hum Brain Mapp       Date:  2003-01       Impact factor: 5.038

3.  A correction method for streak artifacts in gradient-echo EPI using spin-echo EPI reference data.

Authors:  Jun-Young Chung; Yeji Han; Zang-Hee Cho; Hyunwook Park
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

4.  Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences.

Authors:  Stavroula Kyriazi; Matthew Blackledge; David J Collins; Nandita M Desouza
Journal:  Eur Radiol       Date:  2010-06-10       Impact factor: 5.315

5.  Asymmetrical hippocampal connectivity in mesial temporal lobe epilepsy: evidence from resting state fMRI.

Authors:  Fabrício R S Pereira; Andréa Alessio; Maurício S Sercheli; Tatiane Pedro; Elizabeth Bilevicius; Jane M Rondina; Helka F B Ozelo; Gabriela Castellano; Roberto J M Covolan; Benito P Damasceno; Fernando Cendes
Journal:  BMC Neurosci       Date:  2010-06-02       Impact factor: 3.288

6.  Differences in functional MR imaging activation patterns associated with confrontation naming and responsive naming.

Authors:  Sarah Tomaszewki Farias; Gregory Harrington; Catherine Broomand; Maysud Seyal
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

7.  Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging.

Authors:  Bernd U Foerster; Dardo Tomasi; Elisabeth C Caparelli
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

8.  fMRI-acoustic noise alters brain activation during working memory tasks.

Authors:  D Tomasi; E C Caparelli; L Chang; T Ernst
Journal:  Neuroimage       Date:  2005-08-15       Impact factor: 6.556

9.  Self-calibrated trajectory estimation and signal correction method for robust radial imaging using GRAPPA operator gridding.

Authors:  Anagha Deshmane; Martin Blaimer; Felix Breuer; Peter Jakob; Jeffrey Duerk; Nicole Seiberlich; Mark Griswold
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

10.  A circular echo planar sequence for fast volumetric fMRI.

Authors:  Christoph Rettenmeier; Danilo Maziero; Yongxian Qian; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2018-10-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.