Literature DB >> 8795036

Artifact reduction in EPI with phase-encoded reference scan.

X Hu1, T H Le.   

Abstract

Echo-planar imaging is becoming widely used for various applications. However, because of inherent limitations, images obtained with EPI are often degraded by artifacts arising from the inconsistency between the odd and even echoes in the acquired data. Several correction techniques, including those based on reference measurement, have been previously reported. In this paper, a correction method based on phase-encoded reference measurement is described. This technique is demonstrated with experimental data obtained at 4 Tesla and compared with techniques that use nonphase-encoded reference scan. Results from experimental studies indicate that the present approach reduces the ghost intensity by a factor of 2-3.

Mesh:

Substances:

Year:  1996        PMID: 8795036     DOI: 10.1002/mrm.1910360126

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  30 in total

1.  Reproducibility of BOLD-based functional MRI obtained at 4 T.

Authors:  C Tegeler; S C Strother; J R Anderson; S G Kim
Journal:  Hum Brain Mapp       Date:  1999       Impact factor: 5.038

Review 2.  Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Authors:  A M Howseman; R W Bowtell
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

3.  Two-dimensional deghosting for EPI.

Authors:  F Hennel
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

4.  Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan.

Authors:  V J Schmithorst; B J Dardzinski; S K Holland
Journal:  IEEE Trans Med Imaging       Date:  2001-06       Impact factor: 10.048

5.  A correction method for streak artifacts in gradient-echo EPI using spin-echo EPI reference data.

Authors:  Jun-Young Chung; Yeji Han; Zang-Hee Cho; Hyunwook Park
Journal:  MAGMA       Date:  2011-11-10       Impact factor: 2.310

6.  Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

Authors:  Benedikt A Poser; Markus Barth; Pål-Erik Goa; Weiran Deng; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

7.  Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke.

Authors:  Moritz Zaiss; Junzhong Xu; Steffen Goerke; Imad S Khan; Robert J Singer; John C Gore; Daniel F Gochberg; Peter Bachert
Journal:  NMR Biomed       Date:  2014-01-03       Impact factor: 4.044

8.  Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

Authors:  Himanshu Bhat; Qi Yang; Sven Zuehlsdorff; Kuncheng Li; Debiao Li
Journal:  Invest Radiol       Date:  2010-08       Impact factor: 6.016

9.  Influence of selecting EPI readout-encoding bandwidths on arterial spin labeling perfusion MRI.

Authors:  Geon-Ho Jahng; Norbert Schuff
Journal:  MAGMA       Date:  2009-07-04       Impact factor: 2.310

10.  Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects.

Authors:  Hua Li; Zhongliang Zu; Moritz Zaiss; Imad S Khan; Robert J Singer; Daniel F Gochberg; Peter Bachert; John C Gore; Junzhong Xu
Journal:  NMR Biomed       Date:  2014-12-07       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.