Literature DB >> 29993978

Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Rodrigo A Lobos, Tae Hyung Kim, W Scott Hoge, Justin P Haldar.   

Abstract

Structured low-rank matrix models have previously been introduced to enable calibrationless MR image reconstruction from sub-Nyquist data, and such ideas have recently been extended to enable navigator-free echo-planar imaging (EPI) ghost correction. This paper presents a novel theoretical analysis which shows that, because of uniform subsampling, the structured low-rank matrix optimization problems for EPI data will always have either undesirable or non-unique solutions in the absence of additional constraints. This theory leads us to recommend and investigate problem formulations for navigator-free EPI that incorporate side information from either image-domain or k-space domain parallel imaging methods. The importance of using nonconvex low-rank matrix regularization is also identified. We demonstrate using phantom and in vivo data that the proposed methods are able to eliminate ghost artifacts for several navigator-free EPI acquisition schemes, obtaining better performance in comparison with the state-of-the-art methods across a range of different scenarios. Results are shown for both single-channel acquisition and highly accelerated multi-channel acquisition.

Entities:  

Mesh:

Year:  2018        PMID: 29993978      PMCID: PMC6309699          DOI: 10.1109/TMI.2018.2822053

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  32 in total

1.  Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction.

Authors:  Nan-kuei Chen; Alice M Wyrwicz
Journal:  Magn Reson Med       Date:  2004-06       Impact factor: 4.668

2.  Robust 2D phase correction for echo planar imaging under a tight field-of-view.

Authors:  Dan Xu; Kevin F King; Yuval Zur; R Scott Hinks
Journal:  Magn Reson Med       Date:  2010-08-30       Impact factor: 4.668

3.  Correction for geometric distortion and N/2 ghosting in EPI by phase labeling for additional coordinate encoding (PLACE).

Authors:  Qing-San Xiang; Frank Q Ye
Journal:  Magn Reson Med       Date:  2007-04       Impact factor: 4.668

4.  Parallel reconstruction using null operations.

Authors:  Jian Zhang; Chunlei Liu; Michael E Moseley
Journal:  Magn Reson Med       Date:  2011-05-20       Impact factor: 4.668

5.  Comprehensive reconstruction of multi-shot multi-channel diffusion data using mussels.

Authors:  Merry Mani; Vincent Magnotta; Douglas Kelley; Mathews Jacob
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2016-08

6.  Ghost reduction in echo-planar imaging by joint reconstruction of images and line-to-line delays and phase errors.

Authors:  Julianna D Ianni; E Brian Welch; William A Grissom
Journal:  Magn Reson Med       Date:  2017-10-16       Impact factor: 4.668

7.  Off-the-Grid Recovery of Piecewise Constant Images from Few Fourier Samples.

Authors:  Greg Ongie; Mathews Jacob
Journal:  SIAM J Imaging Sci       Date:  2016-07-21       Impact factor: 2.867

8.  P-LORAKS: Low-rank modeling of local k-space neighborhoods with parallel imaging data.

Authors:  Justin P Haldar; Jingwei Zhuo
Journal:  Magn Reson Med       Date:  2015-05-07       Impact factor: 4.668

9.  Low-rank modeling of local k-space neighborhoods (LORAKS) for constrained MRI.

Authors:  Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2014-03       Impact factor: 10.048

10.  Joint correction of Nyquist artifact and minuscule motion-induced aliasing artifact in interleaved diffusion weighted EPI data using a composite two-dimensional phase correction procedure.

Authors:  Hing-Chiu Chang; Nan-Kuei Chen
Journal:  Magn Reson Imaging       Date:  2016-04-22       Impact factor: 2.546

View more
  10 in total

1.  Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstruction.

Authors:  Berkin Bilgic; Itthi Chatnuntawech; Mary Kate Manhard; Qiyuan Tian; Congyu Liao; Siddharth S Iyer; Stephen F Cauley; Susie Y Huang; Jonathan R Polimeni; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-05-20       Impact factor: 4.668

2.  Simultaneous auto-calibration and gradient delays estimation (SAGE) in non-Cartesian parallel MRI using low-rank constraints.

Authors:  Wenwen Jiang; Peder E Z Larson; Michael Lustig
Journal:  Magn Reson Med       Date:  2018-03-09       Impact factor: 4.668

Review 3.  What's new and what's next in diffusion MRI preprocessing.

Authors:  Chantal M W Tax; Matteo Bastiani; Jelle Veraart; Eleftherios Garyfallidis; M Okan Irfanoglu
Journal:  Neuroimage       Date:  2021-12-26       Impact factor: 7.400

4.  Improved MUSSELS reconstruction for high-resolution multi-shot diffusion weighted imaging.

Authors:  Merry Mani; Hemant Kumar Aggarwal; Vincent Magnotta; Mathews Jacob
Journal:  Magn Reson Med       Date:  2019-12-02       Impact factor: 4.668

5.  Motion-robust reconstruction of multishot diffusion-weighted images without phase estimation through locally low-rank regularization.

Authors:  Yuxin Hu; Evan G Levine; Qiyuan Tian; Catherine J Moran; Xiaole Wang; Valentina Taviani; Shreyas S Vasanawala; Jennifer A McNab; Bruce A Daniel; Brian L Hargreaves
Journal:  Magn Reson Med       Date:  2018-10-22       Impact factor: 4.668

6.  Wave-LORAKS: Combining wave encoding with structured low-rank matrix modeling for more highly accelerated 3D imaging.

Authors:  Tae Hyung Kim; Berkin Bilgic; Daniel Polak; Kawin Setsompop; Justin P Haldar
Journal:  Magn Reson Med       Date:  2018-09-25       Impact factor: 4.668

7.  Minimizing echo and repetition times in magnetic resonance imaging using a double half-echo k-space acquisition and low-rank reconstruction.

Authors:  Mark Bydder; Fadil Ali; Vahid Ghodrati; Peng Hu; Jingwen Yao; Benjamin M Ellingson
Journal:  NMR Biomed       Date:  2020-12-09       Impact factor: 4.478

8.  Robust autocalibrated structured low-rank EPI ghost correction.

Authors:  Rodrigo A Lobos; W Scott Hoge; Ahsan Javed; Congyu Liao; Kawin Setsompop; Krishna S Nayak; Justin P Haldar
Journal:  Magn Reson Med       Date:  2020-12-17       Impact factor: 3.737

9.  Autoregression and Structured Low-Rank Modeling of Sinogram Neighborhoods.

Authors:  Rodrigo A Lobos; Muhammad Usman Ghani; W Clem Karl; Richard M Leahy; Justin P Haldar
Journal:  IEEE Trans Comput Imaging       Date:  2021-09-24

10.  A miniature U-net for k-space-based parallel magnetic resonance imaging reconstruction with a mixed loss function.

Authors:  Lin Xu; Jingwen Xu; Qian Zheng; Jianying Yuan; Jiajia Liu
Journal:  Quant Imaging Med Surg       Date:  2022-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.