| Literature DB >> 35303004 |
Rahaf A Almohareb1, Reem Barakat1, Fatimah Albohairy2.
Abstract
Nickel-titanium (NiTi) instruments used to treat root canal infections are affected by autoclave sterilization in various ways. The aim of this study was to compare the effect of autoclave sterilization on two NiTi rotary instruments that undergo different manufacturing treatments: The electro-polished Race and the heat-treated Race Evo, using scanning electron microscope analysis. In this in-vitro study, Race and Race-Evo instruments were subjected to a number of autoclaving cycles (0, 1, 3, 5, and 10). Scanning electron microscopy images were obtained at 3 mm from the tip of the file at 450x and 1000x magnifications. Surface roughness parameters were measured using ImageJ software. The results showed that autoclave sterilization caused a significant decrease in conventional NiTi Race surface roughness. While in Race Evo, surface roughness increased following the first autoclaving cycle. After 10 autoclaving cycles, surface roughness significantly decreased for both Race and Race Evo files.Entities:
Mesh:
Substances:
Year: 2022 PMID: 35303004 PMCID: PMC8932584 DOI: 10.1371/journal.pone.0265226
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Mean and standard deviation of Race and Race Evo surface roughness in different autoclaving cycles.
| NiTi | Cycle | Surface Roughness Parameters | |||||
|---|---|---|---|---|---|---|---|
| Rq | Ra | Rz | |||||
| Mean | ±Std Deviation | Mean | ±Std Deviation | Mean | ±Std Deviation | ||
|
| 0 | 13.320a1 | ±0.952 | 10.213a1 | ±0.720 | 33.140a1 | ±0.257 |
| 1 | 8.380b1 | ±0.3832 | 6.183b1 | ±0.303 | 19.116b1 | ±0.365 | |
| 3 | 8.969b1` | ±8.969 | 6.53bc1 | ±1.216 | 32.704a1 | ±2.868 | |
| 5 | 7.02bc1 | ±0.771 | 5.004bc1 | ±0.53 | 26.735a1 | ±4.232 | |
| 10 | 5.492c1 | ±0.256 | 3.920c1 | ±0.178 | 16.590b1 | ±3.422 | |
|
| 0 | 7.201a2 | ±0.3286 | 5.154a2 | ±0.306 | 33.1402a2 | ±0.525 |
| 1 | 12.014b2 | ±0.189 | 9.029b2 | ±0.195 | 42.985a2 | ±11.054 | |
| 3 | 10.233c1 | ±0.304 | 7.670c1 | ±0.149 | 32.146a1 | ±11.688 | |
| 5 | 5.532d2 | ±0.427 | 3.971d2 | ±0.328 | 14.925b2 | ±1.063 | |
| 10 | 6.082d2 | ±0.195 | 4.422d2 | ±0.143 | 16.907b1 | ±1.450 | |
Similar letters indicate non-significant values comparing autoclaving cycles within one group of NiTi files. Similar numbers indicate non-significant values comparing Race and Race Evo files in every autoclaving subgroup. Statistical significance was set at p≤0.05.
Fig 13D color surface roughness profiles of Race and Race Evo files (magnification 450x) where x = 1280 px; y = 1024 px and z (intensity) - 26 to 249 representing the lowest valley and highest peak.
a) 0 cycle Race, b) one-time cycled Race, c) three times cycled Race, d) five times cycled Race, e) ten times cycled Race, f) 0 cycle Race Evo, g) one-time cycled Race Evo, h) three times cycled Race Evo, i) five times cycled Race Evo, and j) ten times cycled Race Evo.
Fig 2Changes in surface roughness values at 450x magnification according to NiTi file and number of autoclave cycles a) Ra, b) Rq, and c) Rz.
Paired t-test comparison between surface roughness measured at two different magnifications (Rq 450x - Rq 1000x).
| Autoclave Cycles | NiTi | Mean | Std deviation | Std error | Sig. |
|---|---|---|---|---|---|
|
| Race | 1.8260 | 1.550 | 0.895 | 0.178 |
| Race Evo | 0.4322 | 0.254 | 0.146 | 0.099 | |
|
| Race | 0.9721 | 0.698 | 0.402 | 0.137 |
| Race Evo | 1.1528 | 0.973 | 0.561 | 0.177 | |
|
| Race | 1.2129 | 0.948 | 0.547 | 0.157 |
| Race Evo | 0.6263 | 0.143 | 0.083 | 0.170 | |
|
| Race | 0.1808 | 1.425 | 0.823 | 0.846 |
| Race Evo | 0.0955 | 0.151 | 0.087 | 0.390 | |
|
| Race | 0.6708 | 0.315 | 0.181 | 0.066 |
| Race Evo | 0.6398 | 0.445 | 0.256 | 0.130 |
Statistical significance was set at p≤0.05.