Literature DB >> 18215681

Cutting efficiency of five different types of rotary nickel-titanium instruments.

Edgar Schäfer1, Mirjam Oitzinger.   

Abstract

The purpose of this study was to compare the cutting efficiency of the following rotary nickel-titanium instruments: Alpha-File (Komet, Lemgo, Germany), FlexMaster (VDW, Munich, Germany), Mtwo (VDW, Munich, Germany), ProFile (Dentsply Maillefer, Ballaigues, Switzerland), and RaCe (FKG, La-Chaux-de-Fonds, Switzerland). New .06/25 and .04/35 instruments were used; sample size was 12 for each group. Cutting efficiency of all 120 instruments was determined in a rotary working motion by means of a computer-driven testing device. Special plastic samples with a cylindrical canal were used, and the maximum penetration depth of the instruments into the lumen was the criterion for cutting efficiency. Statistical analysis was performed by using analysis of variance and post hoc Student-Newman-Keuls test. Out of all .06/25 instruments, Mtwo and RaCe displayed significantly greater penetration depths than all other instruments, whereas for the other size FlexMaster, Mtwo, and RaCe were significantly superior to all other instruments (p < 0.05). For both sizes, the significantly lowest values were obtained by ProFile (p < 0.05). Under the condition of this study, Mtwo and RaCe displayed the greatest cutting efficiency.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18215681     DOI: 10.1016/j.joen.2007.10.009

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  21 in total

1.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

2.  The effect of electrical treatment on cyclic fatigue of NiTi instruments.

Authors:  Mohammad Ali Saghiri; Armen Asatourian; Franklin Garcia-Godoy; James L Gutmann; Mehrdad Lotfi; Nader Sheibani
Journal:  Scanning       Date:  2014-05-05       Impact factor: 1.932

3.  An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.

Authors:  B Shiva Kumar; Spoorti Pattanshetty; Manju Prasad; Sunny Soni; Kirti S Pattanshetty; Shiva Prasad
Journal:  J Int Oral Health       Date:  2013-10-26

4.  Cutting efficiency of instruments with different movements: a comparative study.

Authors:  Luigi Tocci; Gianluca Plotino; Dina Al-Sudani; Alessio Giansiracusa Rubini; Gianpaolo Sannino; Lucila Piasecki; Ermanno Putortì; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2015-03-30

5.  A new device to test cutting efficiency of mechanical endodontic instruments.

Authors:  Alessio Giansiracusa Rubini; Gianluca Plotino; Dina Al-Sudani; Nicola M Grande; Gianpaolo Sonnino; Ermanno Putorti; Elisabetta Cotti; Luca Testarelli; Gianluca Gambarini
Journal:  Med Sci Monit       Date:  2014-03-06

6.  The evaluation of two rotary instrumentation techniques under "operator-related variables" standardized conditions.

Authors:  Ozgur Uzun; Ozgur Topuz; Fatma Yalpi; Feyza Unsal; Cumhur Aydin; Emre Bodrumlu
Journal:  Eur J Dent       Date:  2013-10

7.  Geometric analysis of root canals prepared by single twisted file in three different operation modes.

Authors:  Xing-Chen Wu; Ya-Qin Zhu
Journal:  Eur J Dent       Date:  2014-10

8.  Efficacy of two rotary systems in removing gutta-percha and sealer from the root canal walls.

Authors:  Bahareh Dadresanfar; Payman Mehrvarzfar; Mohammad Ali Saghiri; Sedigh Ghafari; Zohreh Khalilak; Mehdi Vatanpour
Journal:  Iran Endod J       Date:  2011-05-15

9.  Structural characterisation and mechanical FE analysis of conventional and M-Wire Ni-Ti alloys used in endodontic rotary instruments.

Authors:  Diogo Montalvão; Francisca Sena Alçada; Francisco Manuel Braz Fernandes; Sancho de Vilaverde-Correia
Journal:  ScientificWorldJournal       Date:  2014-01-20

10.  Comparison of cleaning efficiency and deformation characteristics of Twisted File and ProTaper rotary instruments.

Authors:  Hang Li; Chenzheng Zhang; Qing Li; Changning Wang; Yaling Song
Journal:  Eur J Dent       Date:  2014-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.