SEM observations of nickel-titanium rotary endodontic instruments that fractured during clinical Use.

Satish B Alapati1, William A Brantley, Timothy A Svec, John M Powers, John M Nusstein, Glenn S Daehn.   

Abstract

Numerous discarded ProFile GT, ProFile, and ProTaper nickel-titanium rotary instruments obtained from two graduate endodontic clinics were examined by scanning electron microscopy. These instruments had an unknown history of clinical use and had fractured or experienced considerable permanent torsional deformation without complete separation. The failure processes generally exhibited substantial ductile character, evidenced by a dimpled rupture fracture surface. Crack propagation at grain boundaries and cleavage surfaces indicative of transgranular fracture were observed for some specimens. It appeared that oxide particles from the manufacturing process served as nucleating sites for the microvoids, leading to dimpled rupture. A previously unreported fracture mode also was observed, in which crack propagation, approximately parallel to the local flute orientation, connected pitted regions on the surface. Combining present and previous scanning electron microscopy observations of clinically failed instruments, suggestions are offered for improving their fracture resistance.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15614004     DOI: 10.1097/01.don.0000132301.87637.4a

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  34 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  Sealer penetration: effect of separated file's cross-section, taper and motion characteristics.

Authors:  Ayhan Eymirli; Emel Uzunoğlu Özyürek; Ahmet Serper
Journal:  Clin Oral Investig       Date:  2020-06-19       Impact factor: 3.573

3.  The effect of electrical treatment on cyclic fatigue of NiTi instruments.

Authors:  Mohammad Ali Saghiri; Armen Asatourian; Franklin Garcia-Godoy; James L Gutmann; Mehrdad Lotfi; Nader Sheibani
Journal:  Scanning       Date:  2014-05-05       Impact factor: 1.932

4.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

5.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

6.  Retrieval of a separated nickel-titanium instrument using a modified 18-guage needle and cyanoacrylate glue: a case report.

Authors:  Syed Mukhtar-Un-Nisar Andrabi; Ashok Kumar; Huma Iftekhar; Sharique Alam
Journal:  Restor Dent Endod       Date:  2013-05-28

7.  Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM study.

Authors:  N Subha; Vimal K Sikri
Journal:  J Conserv Dent       Date:  2011-07

8.  Effect of repetitive pecking at working length for glide path preparation using G-file.

Authors:  Jung-Hong Ha; Hyo-Jin Jeon; Rashid El Abed; Seok-Woo Chang; Sung-Kyo Kim; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2015-01-07

9.  Cyclic Fatigue Resistance and Fractographic Analysis of Race and Protaper Rotary NiTi Instruments.

Authors:  Shahram Azimi; Parisa Delvari; Hamid Cyrus Hajarian; Mohammad Ali Saghiri; Kasra Karamifar; Mehrdad Lotfi
Journal:  Iran Endod J       Date:  2011-05-15

10.  An in vitro comparison of cyclic fatigue resistance of ProTaper universal and GT series X files.

Authors:  Ramiro Montenegro-Santillán; Teresa Alegre-Domingo; Vicente Faus-Matoses; Vicente Faus-Llácer
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-05-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.