Abstract

AIM: To determine the cleaning effectiveness and shaping ability of ProTaper and RaCe nickel-titanium rotary instruments during the preparation of curved root canals in extracted human teeth.
METHODOLOGY: A total of 48 root canals of mandibular and maxillary molars with curvatures ranging between 25 degrees and 35 degrees were divided into two groups of 24 canals each. Based on radiographs taken prior to instrumentation with the initial instrument inserted into the canal, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared using a crown-down preparation technique. After each instrument, the root canals were flushed with a 2.5% NaOCl solution and at the end of instrumentation with NaCl. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis program. After splitting the roots longitudinally, the amount of debris and smear layer was quantified on the basis of a numerical evaluation scale, using a scanning electron microscope (SEM). The data established for scoring the debris and the smear layer were separately recorded and analysed statistically using the Wilcoxon test.
RESULTS: Two ProTaper and three RaCe instruments fractured; there was no significant difference between instrument types (P > 0.05). Completely clean root canals were never observed. For debris removal, RaCe files achieved significantly better results (P < 0.001) than ProTaper instruments. The results for remaining smear layer were similar and not significantly different (P > 0.05). RaCe instruments maintained the original canal curvature significantly better (P < 0.05) than ProTaper instruments. No significant differences were detected between the instruments (P > 0.05) for the time taken to prepare the canals.
CONCLUSIONS: Under the conditions of this study, RaCe instruments resulted in relatively good cleaning and maintained the original curvature significantly better than ProTaper did.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15056350     DOI: 10.1111/j.0143-2885.2004.00783.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  39 in total

1.  A comparative evaluation of gutta-percha filled areas in curved root canals obturated with different techniques.

Authors:  Edgar Schäfer; Birthe Nelius; Sebastian Bürklein
Journal:  Clin Oral Investig       Date:  2011-01-20       Impact factor: 3.573

2.  A Comparative SEM Investigation of Smear Layer Remaining on Dentinal Walls by Three Rotary NiTi Files with Different Cross Sectional Designs in Moderately Curved Canals.

Authors:  Gaurav Sharma; Pooja Kakkar; Asit Vats
Journal:  J Clin Diagn Res       Date:  2015-03-01

3.  Modifications in Canal Anatomy of Curved Canals of Mandibular First Molars by two Glide Path Instruments using CBCT.

Authors:  Anil Dhingra; Nayasha Manchanda
Journal:  J Clin Diagn Res       Date:  2014-11-20

4.  Evaluation of the Canal Transportation Following Glide Path Preparation with Different Rotary Systems: A Comparative Study.

Authors:  Mohsen Aminsobhani; Fatemeh Hamidzadeh; Arvin Rezaei Avval; Farid Merrikhi; Ehsan Sadri
Journal:  ScientificWorldJournal       Date:  2022-06-30

5.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

6.  Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file.

Authors:  Smita Singh; Neeraj Nigam
Journal:  J Conserv Dent       Date:  2010-04

7.  Highly concentrated EDTA gel improves cleaning efficiency of root canal preparation in vitro.

Authors:  P Putzer; L Hoy; H Günay
Journal:  Clin Oral Investig       Date:  2008-04-16       Impact factor: 3.573

8.  Histological analysis of cleaning efficacy of hand and rotary instruments in the apical third of the root canal: A comparative study.

Authors:  Ashtha Arya; Dildeep Bali; Mandeep S Grewal
Journal:  J Conserv Dent       Date:  2011-07

9.  Microscopic evaluation of cleaning efficiency of three different nickel-titanium rotary instruments.

Authors:  Maryam Bidar; Saeed Moradi; Maryam Forghani; Salma Bidad; Mahtab Azghadi; Shahrzad Rezvani; Shirin Khoynezhad
Journal:  Iran Endod J       Date:  2010-11-15

10.  Shaping ability of nickel-titanium rotary instruments in curved root canals.

Authors:  Ali Talati; Saeed Moradi; Maryam Forghani; Ali Monajemzadeh
Journal:  Iran Endod J       Date:  2013-05-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.