Literature DB >> 24138190

Atomic force microscopic evaluation of nanostructure alterations of rotary NiTi instruments after immersion in irrigating solutions.

D M Fayyad1, A H Mahran.   

Abstract

AIM: To compare the effect of 5.25% NaOCl or 17% EDTA solutions on the surface topography and roughness of GTX, TF, RaCe and Hero Shaper instruments using atomic force microscopy (AFM) analysis.
METHODOLOGY: Four new files of each brand were subjected to AMF analysis; then each group was subdivided into two subgroups (n = 2) in which instruments were immersed in either 5.25% NaOCl or 17% EDTA solutions for 5 min, thereafter subjected to AFM analysis again. Ra and the RMS values were chosen to investigate the surface features of endodontic files.
RESULTS: Before immersion in irrigating solution, TF and Hero Shaper instruments had the significantly highest roughness values and RaCe had the significantly lowest values (P ≤ 0.05). After immersion in NaOCl, GTX and RaCe instruments were not significantly different from the new instruments, nor between them. There was a significant increase in Ra and RMS values for TF and Hero Shaper instruments over that of untreated ones and that of GTX and RaCe instruments. No significant increase in surface roughness of the instruments was recorded with EDTA.
CONCLUSION: 17% EDTA did not significantly affect the surface roughness of the instruments, whilst 5.25% NaOCl increased the surface roughness of TF and Hero Shaper significantly more than that of RaCe and GTX instruments.
© 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  AFM; EDTA; NaOCL; NiTi rotary files

Mesh:

Substances:

Year:  2013        PMID: 24138190     DOI: 10.1111/iej.12189

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  7 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  The effect of electrical treatment on cyclic fatigue of NiTi instruments.

Authors:  Mohammad Ali Saghiri; Armen Asatourian; Franklin Garcia-Godoy; James L Gutmann; Mehrdad Lotfi; Nader Sheibani
Journal:  Scanning       Date:  2014-05-05       Impact factor: 1.932

3.  Effect of NaOCl and EDTA Solutions on Topography of ESX, TruShape and ProTaper Gold NiTi Rotary Instruments - An Atomic Force Microscopic Study.

Authors:  Abhijit M Pallewar; Roopadevi Garlapati; Bolla Nagesh; Praveen Kumar Gali; Chukka Ram Sunil; Varri Sujana
Journal:  J Conserv Dent       Date:  2020-08-04

4.  Qualitative Assessment of the Surface Topographic Changes of XP-endo Shaper and TruNatomy files after exposure to Sodium Hypochlorite and Ethylenediaminetetraacetic Acid.

Authors:  Jerry Jose; Akshay Khandelwal; Riluwan Siddique
Journal:  Eur Endod J       Date:  2021-08

5.  New heat-treated vs electropolished nickel-titanium instruments used in root canal treatment: Influence of autoclave sterilization on surface roughness.

Authors:  Rahaf A Almohareb; Reem Barakat; Fatimah Albohairy
Journal:  PLoS One       Date:  2022-03-18       Impact factor: 3.240

6.  The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2018-02-02

Review 7.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.