Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

K Yılmaz1, G Uslu2, T Özyürek3.   

Abstract

AIM: To compare the effect of autoclave cycles on the surface topography and roughness of HyFlex CM and HyFlex EDM instruments using atomic force microscopy (AFM) analysis.
METHODOLOGY: Eight new files of each brand were subdivided into four subgroups (n = 2/each subgroup). One group was allocated as the control group and not subjected to autoclave sterilization. The other three groups were subjected to different numbers (1, 5, and 10) of autoclave sterilization cycles. After the cycle instruments were subjected to AFM analysis. Roughness average (Ra) and the root mean square (RMS) values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way ANOVA and post hoc Tamhane tests at 5% significant level.
RESULTS: The lowest Ra and RMS values were observed in the HyFlex EDM files that served as the control and in those subjected to a single cycle of autoclave sterilization (P < 0.05). The highest Ra and RMS values were observed in the HyFlex CM and HyFlex EDM files that were subjected to 10 cycles of autoclave sterilization (P < 0.05). The surface roughness values of the HyFlex CM group showed a significant increase after ten autoclave cycles, whereas those of the HyFlex EDM group exhibited a significant change after five autoclave cycles (P < 0.05).
CONCLUSIONS: Although the initial surface roughness values of the HyFlex EDM files were lower than those of the HyFlex CM files, the surface roughness values of the EDM files showed a statistically significant increase after 5 cycles of autoclave sterilization. In contrast, the surface roughness values of the HyFlex CM files did not increase until 10 cycles of autoclave sterilization. CLINICAL RELEVANCE: Present study indicated that autoclave sterilization negatively affected the surface roughness of the tested NiTi files.

Entities:  

Keywords:  AFM; Autoclave sterilization; HyFlex CM; HyFlex EDM; Nickel–titanium

Mesh:

Year:  2018        PMID: 29442187     DOI: 10.1007/s00784-018-2382-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  28 in total

1.  Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments.

Authors:  Gianluca Plotino; Alberto Costanzo; Nicola M Grande; Renata Petrovic; Luca Testarelli; Gianluca Gambarini
Journal:  J Endod       Date:  2011-11-21       Impact factor: 4.171

2.  Mechanical properties of nickel-titanium rotary instruments produced with a new manufacturing technique.

Authors:  G Gambarini; G Plotino; N M Grande; D Al-Sudani; M De Luca; L Testarelli
Journal:  Int Endod J       Date:  2011-01-10       Impact factor: 5.264

3.  Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments.

Authors:  D Zhao; Y Shen; B Peng; M Haapasalo
Journal:  Int Endod J       Date:  2015-10-12       Impact factor: 5.264

4.  Evaluation of surface topography changes in three NiTi file systems using rotary and reciprocal motion: An atomic force microscopy study.

Authors:  Yalpi Fatma; Uzun Ozgur
Journal:  Microsc Res Tech       Date:  2013-12-26       Impact factor: 2.769

5.  Effect of repeated simulated clinical use and sterilization on the cutting efficiency and flexibility of Hyflex CM nickel-titanium rotary files.

Authors:  Scott T Seago; Brian E Bergeron; Timothy C Kirkpatrick; Mark D Roberts; Howard W Roberts; Van T Himel; Kent A Sabey
Journal:  J Endod       Date:  2015-03-03       Impact factor: 4.171

6.  Fatigue resistance of rotary instruments manufactured using different nickel-titanium alloys: a comparative study.

Authors:  Gianluca Plotino; Luca Testarelli; Dina Al-Sudani; Gianlcarlo Pongione; Nicola M Grande; Gianluca Gambarini
Journal:  Odontology       Date:  2012-10-18       Impact factor: 2.634

7.  Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments.

Authors:  Lígia Carolina Moreira Braga; Ana Cristina Faria Silva; Vicente Tadeu Lopes Buono; Maria Guiomar de Azevedo Bahia
Journal:  J Endod       Date:  2014-04-29       Impact factor: 4.171

8.  Structural analysis of HyFlex EDM instruments.

Authors:  F Iacono; C Pirani; L Generali; G Bolelli; P Sassatelli; L Lusvarghi; M G Gandolfi; L Giorgini; C Prati
Journal:  Int Endod J       Date:  2016-03-11       Impact factor: 5.264

9.  HyFlex nickel-titanium rotary instruments after clinical use: metallurgical properties.

Authors:  Y Shen; J M Coil; H Zhou; Y Zheng; M Haapasalo
Journal:  Int Endod J       Date:  2013-01-21       Impact factor: 5.264

10.  Structural effects of sodium hypochlorite solution on RaCe rotary nickel-titanium instruments: an atomic force microscopy study.

Authors:  Ozgur Topuz; Cumhur Aydin; Ozgur Uzun; Ugur Inan; Tayfun Alacam; Yasar M Tunca
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2008-03-10
View more
  3 in total

1.  Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments.

Authors:  Wooyoung Kim; Soram Oh; Gil-Joo Ryu; Tae-Hwan Kim; Sung-Jae Kim; Dong-Hyung Kim; Bin-Na Lee; Kee-Yeon Kum; Seok Woo Chang; Ji-Hyun Jang
Journal:  Odontology       Date:  2019-09-11       Impact factor: 2.634

2.  New heat-treated vs electropolished nickel-titanium instruments used in root canal treatment: Influence of autoclave sterilization on surface roughness.

Authors:  Rahaf A Almohareb; Reem Barakat; Fatimah Albohairy
Journal:  PLoS One       Date:  2022-03-18       Impact factor: 3.240

Review 3.  Metallurgical Tests in Endodontics: A Narrative Review.

Authors:  Alessio Zanza; Marco Seracchiani; Rodolfo Reda; Gabriele Miccoli; Luca Testarelli; Dario Di Nardo
Journal:  Bioengineering (Basel)       Date:  2022-01-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.