Literature DB >> 10687515

Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopy.

C Eggert1, O Peters, F Barbakow.   

Abstract

Used rotary nickel-titanium instruments require frequent replacing. This laboratory study evaluated defects of Lightspeed cutting tips before and after usage. The instruments were fixed into custom-made holders, the cutting heads photographed in a scanning electron microscope at x120 to x400 magnification at preset points around the cutting tip (90, 180, 270 and 360 degrees) and head-on. Instrument sizes 20 to 32.5, 35 to 60, and 65 to 100 were used in 9, 18, and 36 canals, respectively, and autoclaved after shaping every third root canal. The used instruments were cleaned and then reexamined in a scanning electron microscope as before. The presence of 11 types of conditions was scored from the pre- and postusage photographs. No instruments fractured during the test, but all the cutting heads had one or more imperfections, even before usage. The presence of debris, pitting, and metal strips changed significantly. Imperfections were found on new and used Lightspeed cutting heads, indicating the general difficulty in machining defect-free nickel-titanium rotary instruments. However, high quality should remain a goal to improve instrument efficiency.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10687515     DOI: 10.1016/S0099-2399(99)80289-1

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  Comparison and evaluation of surface deformation of Hyflex controlled memory and Hyflex electric discharge machining nickel titanium rotary files and cyclic fatigue resistance after instrumentation and heat sterilization - An in vitro study.

Authors:  Paramarshi Das; D V Swapna; Roopa R Nadig
Journal:  J Conserv Dent       Date:  2020-08-04

3.  Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM study.

Authors:  N Subha; Vimal K Sikri
Journal:  J Conserv Dent       Date:  2011-07

4.  Scanning electron microscopic evaluation of the influence of manual and mechanical glide path on the surface of nickel-titanium rotary instruments in moderately curved root canals: An in-vivo study.

Authors:  Dishant Patel; Kusum Bashetty; A Srirekha; S Archana; B Savitha; R Vijay
Journal:  J Conserv Dent       Date:  2016 Nov-Dec

5.  Analysis of Surface Characteristics of ProTaper Universal and ProTaper Next Instruments by Scanning Electron Microscopy.

Authors:  Jeffery Bennett; Kwok-Hung Chung; Hanson Fong; James Johnson; Avina Paranjpe
Journal:  J Clin Exp Dent       Date:  2017-07-01

6.  The Effect of Multiple Autoclave Sterilization on the Cyclic Fatigue of Three Heat-Treated Nickel-Titanium Rotary Files: EdgeFile X7, Vortex Blue, and TRUShape.

Authors:  Reham Sharroufna; Mohammed Mashyakhy
Journal:  Biomed Res Int       Date:  2020-12-14       Impact factor: 3.411

7.  Evaluation of usage-induced degradation of different endodontic file systems.

Authors:  Shekhar Bhatia; Venkateshbabu Nagendrababu; Ove A Peters; Amr Fawzy; Umer Daood
Journal:  Sci Rep       Date:  2021-04-27       Impact factor: 4.379

8.  A novel approach to determine the effect of irrigation on temperature and failure of Ni-Ti endodontic rotary files.

Authors:  Sayed Ali Mousavi; Vida Kargar-Dehnavi; Sayed Amir Mousavi
Journal:  Dent Res J (Isfahan)       Date:  2012-05

9.  Laboratory Rational of Changes in the Crystal Lattice of Nickel-Titanium Endodontic Rotary Files in Autoclaving.

Authors:  Zurab Khabadze; Oleg Mordanov; Mariya Balashova; Leonid Stolov; Amaliya Pangratyan; Roza Bokova; Shamil Nazhmudinov; Shamil Solimanov; Anastasiya Kuznetsova; Anzhela Adzhieva; Omargadzhi Magomedov
Journal:  Int J Dent       Date:  2020-01-25

10.  Effect of Sterilization on Cyclic Fatigue Resistance of Proflexendo Endodontic Rotary Files.

Authors:  Emad O Alshwaimi
Journal:  Saudi J Med Med Sci       Date:  2019-02-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.