| Literature DB >> 34944887 |
Fabio Giannone1,2,3, Emanuele Felli1,2,3, Zineb Cherkaoui1,2, Pietro Mascagni3, Patrick Pessaux1,2,3.
Abstract
Artificial intelligence makes surgical resection easier and safer, and, at the same time, can improve oncological results. The robotic system fits perfectly with these more or less diffused technologies, and it seems that this benefit is mutual. In liver surgery, robotic systems help surgeons to localize tumors and improve surgical results with well-defined preoperative planning or increased intraoperative detection. Furthermore, they can balance the absence of tactile feedback and help recognize intrahepatic biliary or vascular structures during parenchymal transection. Some of these systems are well known and are already widely diffused in open and laparoscopic hepatectomies, such as indocyanine green fluorescence or ultrasound-guided resections, whereas other tools, such as Augmented Reality, are far from being standardized because of the high complexity and elevated costs. In this paper, we review all the experiences in the literature on the use of artificial intelligence systems in robotic liver resections, describing all their practical applications and their weaknesses.Entities:
Keywords: artificial intelligence; augmented reality; image-guided surgery; liver surgery; robotic
Year: 2021 PMID: 34944887 PMCID: PMC8699460 DOI: 10.3390/cancers13246268
Source DB: PubMed Journal: Cancers (Basel) ISSN: 2072-6694 Impact factor: 6.639
Figure 1(A) Surgical preoperative planning through 3D reconstruction of an anatomical S5 segmentectomy. The tumor is colored in green and the theorical resection plane in red. (B–D) Intraoperative superimposition of planned resection area rendering. Vascular and biliary structures are projected during different phases of parenchymal transection, with the identification of the S5 vascular pedicle.
Figure 2Projection of a virtual liver 3D reconstruction on the skin surface in relation to some external landmarks. The positioning of the optical port (left) is guided by the inferior border of the liver and the resection planned. After the first trocar is inserted, the “see-through” view will aid the operator to place other robotic ports (right).
Figure 3Use of Augmented Reality in planning needle placement during a percutaneous Radiofrequency liver ablation.
Figure 4Robotic “split-view”. Through a dedicated probe and a specific software, the surgeon can shift from to the endoscopic to the ultrasound view or create a split-view with both the images. In this figure, a 3D model was added intraoperatively at the same time to check the tumoral vascular relationship studied preoperatively.