| Literature DB >> 32364353 |
Ki-Young Lee1, Kyung Su Shin2, Ji-Hye Jung1, Hye-Won Cho1, Kyung-Hwan Kwon2, Yu-Lee Kim1.
Abstract
OBJECTIVES: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants.Entities:
Keywords: Dental implants; Regression analysis; Screw loosening
Year: 2020 PMID: 32364353 PMCID: PMC7222622 DOI: 10.5125/jkaoms.2020.46.2.133
Source DB: PubMed Journal: J Korean Assoc Oral Maxillofac Surg ISSN: 1225-1585
Characteristics of the subjects and implants in this study
| No. of patients or implants (%) | ||
|---|---|---|
| Sex | Male | 448 (53.5) |
| Female | 389 (46.5) | |
| Age (yr) | ≤39 | 104 (12.4) |
| 40-49 | 132 (15.8) | |
| 50-59 | 319 (38.1) | |
| 60-69 | 186 (22.2) | |
| ≥70 | 96 (11.5) | |
| Implants (manufacturer) | ET (Dio) | 189 (9.8) |
| GSIII (Osstem) | 11 (0.6) | |
| TSIII (Osstem) | 232 (12.0) | |
| USII (Osstem) | 356 (18.5) | |
| Pitt-easy (Oraltronics) | 94 (4.9) | |
| Restore (Lifecore Biomedical) | 4 (0.2) | |
| Osseotite (Biomet 3I) | 499 (25.9) | |
| Xive (Friadent) | 543 (28.2) | |
| Implant diameter (mm) | ≤3.5 | 177 (9.2) |
| 3.75-4.1 | 1,009 (52.3) | |
| 4.5-4.9 | 327 (17.0) | |
| ≥5 | 415 (21.5) | |
| Implant length (mm) | ≤9.5 | 87 (4.5) |
| 10-11.5 | 1,269 (65.8) | |
| 12-14 | 450 (23.3) | |
| ≥15 | 122 (6.3) | |
| Arch | Maxilla | 949 (49.2) |
| Mandible | 979 (50.8) | |
| Position | Anterior | 332 (17.2) |
| Premolar | 423 (21.9) | |
| Molar | 1,173 (60.8) | |
| Implant–abutment connection type | Internal hex | 923 (47.9) |
| External hex | 1,005 (52.1) | |
| Type of retention | Cement | 1,063 (55.1) |
| Screw | 865 (44.9) | |
| Type of prosthesis | Implant retained overdenture | 32 (1.7) |
| Splinted crown | 1,188 (61.6) | |
| Cantilever bridge | 17 (0.9) | |
| Single crown | 691 (35.8) | |
| Opposing tooth | Denture | 61 (3.2) |
| Fixed prosthesis | 380 (19.7) | |
| Implant-supported prosthesis | 358 (18.6) | |
| Natural tooth | 1,129 (58.6) | |
Incidence of screw loosening and fracture
| No. of implants (%) | |||
|---|---|---|---|
| Screw loosening | Incidence | No | 1,789 (92.8) |
| Yes | 139 (7.2) | ||
| Frequency | Once | 108 (77.7) | |
| Twice | 20 (14.4) | ||
| 3 times or more | 11 (7.9) | ||
| Onset (months since loading) | <6 | 70 (50.4) | |
| 6-12 | 29 (20.9) | ||
| 12-24 | 19 (13.7) | ||
| ≥24 | 21 (15.1) | ||
| Screw fracture | Incidence | No | 1,926 (99.9) |
| Yes | 2 (0.1) | ||
| Onset (months since loading) | <6 | 1 (50.0) | |
| ≥6 | 1 (50.0) | ||
| Screw fracture after screw loosening | No | 1 (50.0) | |
| Yes | 1 (50.0) | ||
Screw loosening by sex and age
| Screw loosening | χ2 |
| |||
|---|---|---|---|---|---|
|
| |||||
| No | Yes | ||||
| Sex | Male | 397 (88.6) | 51 (11.4) | 2.747 | 0.097 |
| Female | 358 (92.0) | 31 (8.0) | |||
| Age (yr) | ≤39 | 94 (90.4) | 10 (9.6) | 1.884 | 0.757 |
| 40-49 | 119 (90.2) | 13 (9.8) | |||
| 50-59 | 289 (90.6) | 30 (9.4) | |||
| 60-69 | 170 (91.4) | 16 (8.6) | |||
| ≥70 | 83 (86.5) | 13 (13.5) | |||
Values are presented as number of patients (%).
Screw loosening according to arch and position
| Screw loosening | χ2 |
| |||
|---|---|---|---|---|---|
|
| |||||
| No | Yes | ||||
| Arch | Maxilla | 878 (92.5) | 71 (7.5) | 0.207 | 0.649 |
| Mandible | 911 (93.1) | 68 (6.9) | |||
| Position | Anterior | 309 (93.1) | 23 (6.9) | 10.500 | 0.005 |
| Premolar | 407 (96.2) | 16 (3.8) | |||
| Molar | 1,073 (91.5) | 100 (8.5) | |||
P<0.05.
Values are presented as number of implants (%).
Screw loosening by the implants used in this study
| Screw loosening | χ2 |
| |||
|---|---|---|---|---|---|
|
| |||||
| No | Yes | ||||
| Implants (manufacturer) | ET (Dio) | 163 (86.2) | 26 (13.8) | 38.912 | 0.000 |
| GSIII (Osstem) | 11 (100) | 0 (0) | |||
| TSIII (Osstem) | 225 (97.0) | 7 (3.0) | |||
| USII (Osstem) | 331 (93.0) | 25 (7.0) | |||
| Pitt-easy (Oraltronics) | 78 (83.0) | 16 (17.0) | |||
| Restore (Lifecore Biomedical) | 4 (100) | 0 (0) | |||
| Osseotite (Biomet 3I) | 459 (92.0) | 40 (8.0) | |||
| Xive (Friadent) | 518 (95.4) | 25 (4.6) | |||
| Implant diameter (mm) | ≤3.5 | 169 (95.5) | 8 (4.5) | 39.409 | 0.000 |
| 3.75-4.1 | 952 (94.4) | 57 (5.6) | |||
| 4.5-4.9 | 312 (95.4) | 15 (4.6) | |||
| ≥5 | 356 (85.8) | 59 (14.2) | |||
| Implant length (mm) | ≤9.5 | 83 (95.4) | 4 (4.6) | 2.791 | 0.425 |
| 10-11.5 | 1,169 (92.1) | 100 (7.9) | |||
| 12-14 | 422 (93.8) | 28 (6.2) | |||
| ≥15 | 115 (94.3) | 7 (5.7) | |||
P<0.05.
Values are presented as number of implants (%).
Screw loosening according to the implant–abutment connection type and implant prosthesis retention type
| Screw loosening | χ2 |
| |||
|---|---|---|---|---|---|
|
| |||||
| No | Yes | ||||
| Implant–abutment connection type | Internal hex | 873 (94.6) | 50 (5.4) | 8.504 | 0.004 |
| External hex | 916 (91.1) | 89 (8.9) | |||
| Type of retention | Cement | 1,011 (95.1) | 52 (4.9) | 19.026 | 0.000 |
| Screw | 778 (89.9) | 87 (10.1) | |||
P<0.05.
Values are presented as number of implants (%).
Screw loosening according to implant prosthesis type and opposing teeth
| Screw loosening | χ2 |
| |||
|---|---|---|---|---|---|
|
| |||||
| No | Yes | ||||
| Type of prosthesis | Implant-retained overdenture | 32 (100) | 0 (0) | 77.392 | 0.000 |
| Splinted crown | 1,148 (96.6) | 40 (3.4) | |||
| Cantilever bridge | 15 (88.2) | 2 (11.8) | |||
| Single crown | 594 (86.0) | 97 (14.0) | |||
| Opposing tooth | Denture | 61 (100) | 0 (0.0) | 6.325 | 0.097 |
| Fixed prosthesis | 357 (93.9) | 23 (6.1) | |||
| Implant-supported prosthesis | 331 (92.5) | 27 (7.5) | |||
| Natural tooth | 1,040 (92.1) | 89 (7.9) | |||
P<0.05.
Values are presented as number of implants (%).
Characteristics of the subjects and implants in this study with two or more incidents of screw loosening
| No. of patients or implants (%) | ||
|---|---|---|
| Sex | Male | 18 (75.0) |
| Female | 6 (25.0) | |
| Age (yr) | ≤39 | 1 (4.2) |
| 40-49 | 5 (20.8) | |
| 50-59 | 10 (41.7) | |
| 60-69 | 6 (25.0) | |
| ≥70 | 2 (8.3) | |
| Implants (manufacturer) | ET (Dio) | 10 (32.3) |
| GSIII (Osstem) | 0 (0) | |
| TSIII (Osstem) | 0 (0) | |
| USII (Osstem) | 7 (22.6) | |
| Pitt-easy (Oraltronics) | 4 (12.9) | |
| Restore (Lifecore Biomedical) | 0 (0) | |
| Osseotite (Biomet 3I) | 8 (25.8) | |
| Xive (Friadent) | 2 (6.5) | |
| Implant diameter (mm) | ≤3.5 | 0 (0) |
| 3.75-4.1 | 10 (32.3) | |
| 4.5-4.9 | 2 (6.5) | |
| ≥5 | 19 (61.3) | |
| Implant length (mm) | ≤9.5 | 0 (0) |
| 10-11.5 | 28 (90.3) | |
| 12-14 | 3 (9.7) | |
| ≥15 | 0 (0) | |
| Arch | Maxilla | 16 (51.6) |
| Mandible | 15 (48.4) | |
| Position | Anterior | 1 (3.2) |
| Premolar | 3 (9.7) | |
| Molar | 27 (87.1) | |
| Implant-abutment connection type | Internal hex | 7 (22.6) |
| External hex | 24 (77.4) | |
| Type of retention | Cement | 6 (19.4) |
| Screw | 25 (80.6) | |
| Type of prosthesis | Implant-retained overdenture | 0 (0) |
| Splinted crown | 3 (9.7) | |
| Cantilever bridge | 0 (0) | |
| Single crown | 28 (90.3) | |
| Opposing tooth | Denture | 0 (0) |
| Fixed prosthesis | 3 (9.7) | |
| Implant-supported prosthesis | 4 (12.9) | |
| Natural tooth | 24 (77.4) | |
Final binary regression model for screw loosening in dental implants
| Variable | Regression coefficient |
| OR | CI for OR |
|---|---|---|---|---|
| Constant | –2.173 | 0.000 | 0.114 | - |
| Position | ||||
| Anterior dentition | 1.107 | 0.003 | 3.024 | 1.455-6.287 |
| Premolar dentition | - | - | 1 | - |
| Implant diameter (mm) | ||||
| ≤3.5 | –1.117 | 0.024 | 0.327 | 0.124-0.865 |
| 3.75-4.1 | –0.570 | 0.016 | 0.566 | 0.356-0.898 |
| 4.5-4.9 | –0.837 | 0.007 | 0.433 | 0.237-0.792 |
| ≥5 | - | - | 1 | - |
| Type of retention | ||||
| Cement | - | - | 1 | - |
| Screw | 0.458 | 0.033 | 1.581 | 1.037-2.409 |
| Type of prosthesis | ||||
| Single crown | - | - | 1 | - |
| Splinted crown | –1.306 | 0.000 | 0.271 | 0.181-0.405 |
(OR: odds ratio, CI: confidence interval)
P=0.139; Hosmer–Lemeshow test.