Literature DB >> 12498448

Relationship between implant preload and screw loosening on implant-supported prostheses.

Georgios Siamos1, Sheldon Winkler, Kenneth G Boberick.   

Abstract

The purpose of this study was to determine whether varying the preload on the implant-abutment complex would affect screw loosening under simulated loading conditions. Abutment screws in sample models were tightened to 25, 30, 35, and 40 N-cm. One group of samples was allowed to stand for 3 hours after being torqued and then loosened. Another group of samples was retorqued after 10 minutes with the same initial torque value and then allowed to stand for 3 hours before loosening. For the load group of samples, the abutments were torqued into place, retorqued after 10 minutes, and a load applied for 3 hours before loosening. Cyclic loading was carried out using a servo-hydraulic testing machine with the values cycled between 1 and 26 pounds and the load applied directly to the abutments. Analysis of variance, analysis of covariance, and linear regression analysis was performed. Within the parameters of this in vitro investigation, the following recommendations can be made: (1) retightening abutment screws 10 minutes after the initial torque applications should be routinely performed and (2) increasing the torque value for abutment screws above 30 N-cm can be beneficial for abutment-implant stability and to decrease screw loosening.

Mesh:

Substances:

Year:  2002        PMID: 12498448     DOI: 10.1563/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  30 in total

1.  A Simple and Cost Effective Method used for Removal of a Fractured Implant Abutment Screw: A Case Report.

Authors:  Parth Satwalekar; K Subash Chander; B Anantha Reddy; N Sandeep; N Sandeep; Tanushree Satwalekar
Journal:  J Int Oral Health       Date:  2013-10-26

2.  Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading.

Authors:  T Paepoemsin; P A Reichart; P Chaijareenont; F P Strietzel; P Khongkhunthian
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

3.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

5.  Comparison of different fixation techniques for periprosthetic fractures: a biomechanical study of a new implant.

Authors:  Mehmet Nuri Konya; Ugur Yuzuguldu; Recep Altin; Ugur Fidan
Journal:  Int Orthop       Date:  2021-04-17       Impact factor: 3.075

6.  Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

Authors:  Woong-Rae Cho; Yoon-Hyuk Huh; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

7.  Influence of the implant-abutment connection design and diameter on the screw joint stability.

Authors:  Hyon-Mo Shin; Jung-Bo Huh; Mi-Jeong Yun; Young-Chan Jeon; Brian Myung Chang; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-04-22       Impact factor: 1.904

Review 8.  Screw-retained crown restorations of single implants: A step-by-step clinical guide.

Authors:  Mohammad Assaf; Alaa' Z Abu Gharbyeh
Journal:  Eur J Dent       Date:  2014-10

9.  Temperature rise during removal of fractured components out of the implant body: an in vitro study comparing two ultrasonic devices and five implant types.

Authors:  Eric W Meisberger; Sjoerd J G Bakker; Marco S Cune
Journal:  Int J Implant Dent       Date:  2015-03-20

10.  Influence of the implant abutment types and the dynamic loading on initial screw loosening.

Authors:  Eun-Sook Kim; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.