Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years.

Marion E Kreissl1, Thomas Gerds, Robert Muche, Guido Heydecke, Jörg R Strub.   

Abstract

OBJECTIVES: The purpose of this prospective long-term study was to evaluate the incidence of the most common technical problems, namely screw loosening, screw fracture, fracturing of veneering porcelain and framework fracture in implant-supported fixed partial dentures (FPDs), and assess the survival and success rate (event-free survival) after 5 years of function.
MATERIALS AND METHODS: In 76 partially edentulous patients, a total of 205 3i-implants (machined surface) were placed and restored with 112 implant-supported FPDs (46 single crowns, 81 splinted crowns, seven FPD bridges and 23 FPDs with cantilevers). The survival rate of FPDs supported by implants was 94.5% (CI-95: 90.1-98.8) after an average observation period of 5 years. The success rate (event-free survival) of the FPDs was 80% (CI-95: 87.3-72.7). After an observation period of 5 years the cumulative incidence of screw loosening was 6.7% (CI-95: 1.8-11.5), the cumulative incidence for screw fracture was 3.9% (CI-95: 0.1-7.7). Fracture of the veneering porcelain occurred in 5.7% (CI-95: 1.2-10.2) of all FPDs. Fracturing of the suprastructure framework was rare (1%; CI-95: 0-2.9). The overall complication incidence after 5 years was highest in the group of FPDs with cantilever, which showed the lowest success rate 68.6% (CI-95: 50-87.3), followed by single crowns (77.6%; CI-95: 53.3-100) and splinted crowns (86.1%; CI-95: 59.5-100). No complication occurred in FPD bridges.
CONCLUSION: Fixed partial dentures supported by 3i-implants showed low technical complications rates, the most common being loosening of the abutment screw. Managing these complications can cause extra amount of chair-side time and patient dissatisfaction.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17888017     DOI: 10.1111/j.1600-0501.2007.01414.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  25 in total

Review 1.  Dental occlusion: modern concepts and their application in implant prosthodontics.

Authors:  Gunnar E Carlsson
Journal:  Odontology       Date:  2009-01-29       Impact factor: 2.634

2.  The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices.

Authors:  Minoo Mahshid; Aboulfazl Saboury; Seyed Jalil Sadr; Ali Fayyaz; Mahdi Kadkhodazadeh
Journal:  J Periodontal Implant Sci       Date:  2013-10-29       Impact factor: 2.614

3.  Repair of a fractured implant overdenture gold bar: A clinical and laboratory technique report.

Authors:  Fahim Vohra; Amani Al Fawaz
Journal:  Eur J Dent       Date:  2013-07

4.  Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis.

Authors:  Xiaomei Li; Zhizhong Cao; Xiaoqian Qiu; Zhen Tang; Lulu Gong; Dalin Wang
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

5.  The effect of sterilization and number of use on the accuracy of friction-style mechanical torque limiting devices for dental implants.

Authors:  Ali Fayaz; Minoo Mahshid; Aboulfazl Saboury; Seyed Jalil Sadr; Ghassem Ansari
Journal:  Dent Res J (Isfahan)       Date:  2014-01

6.  Technical and Biological Complications of Screw-Retained (CAD/CAM) Monolithic and Partial Veneer Zirconia for Fixed Dental Prostheses on Posterior Implants Using a Digital Workflow: A 3-Year Cross-Sectional Retrospective Study.

Authors:  Paolo De Angelis; Giulio Gasparini; Francesca Camodeca; Silvio De Angelis; Margherita Giorgia Liguori; Edoardo Rella; Francesca Cannata; Antonio D'Addona; Paolo Francesco Manicone
Journal:  Biomed Res Int       Date:  2021-07-06       Impact factor: 3.411

7.  A 3-year prospective cohort study on mandibular anterior cantilever restorations associated with screw-retained implant-supported prosthesis: An in vivo study.

Authors:  Vizaikumar Vasudha Nelluri; Kandathilparambil Maria Roseme; Rajani Kumar Gedela
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

8.  A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: Application of a triple-scan protocol.

Authors:  Stefan Holst; Matthias Karl; Manfred Wichmann; Ragai E Matta
Journal:  J Dent Biomech       Date:  2012-07-20

9.  The effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants.

Authors:  Aboulfazl Saboury; Seyed Jalil Sadr; Ali Fayaz; Minoo Mahshid
Journal:  J Dent (Tehran)       Date:  2013-01-31

10.  The effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants.

Authors:  Minoo Mahshid; Aboulfazl Saboury; Ali Fayaz; Seyed Jalil Sadr; Friedrich Lampert; Maziar Mir
Journal:  Clin Cosmet Investig Dent       Date:  2012-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.