Literature DB >> 11168237

An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses.

R Pietrabissa1, L Gionso, V Quaglini, E Di Martino, M Simion.   

Abstract

In common practice a perfect fit of the prosthetic framework with the implant abutments is almost impossible to achieve. The mismatch, which is principally induced by the technological process adopted to manufacture the fixed prostheses, strains the framework thus generating constraint reactions. These are static forces that load the implant components and the bone at the implant-bone interface and may cause the bone remodelling. Depending on the magnitude of such forces, i.e. depending on the magnitude of the mismatch, the bone remodelling may lead to the loosening of the screws and of the implant-bone interface and hence cause implant failure. The present study shows an in vitro comparison of 3 different connecting abutments (standard, EsthetiCone and CerAdapt, Nobel Biocare AB, Göteborg, Sweden) with relation to the mechanical stresses induced by geometrical mismatches (technology induced errors). Two experimental devices were purposely realized and used to assess the ability of the different abutments to compensate errors. One was designed for translation errors and the other for rotation errors. The experimental apparatus set-up includes 2 freestanding implants supporting a prosthetic structure and the connecting abutments. The implants and the abutments were used as delivered by the manufacturer, while the prostheses were purposely realized and instrumented with strain gauges. The data obtained with the error devices do not give quantitative information on what happens in clinical applications where the implants are connected to living bone, which is a tissue much more deformable than the steel used for the error devices. Results allow direct comparisons of the behaviour of the different investigated abutments with respect to position errors. The CerAdapt system (cement retained ceramic abutments) showed the least strain in presence of translation errors. The standard system (screw retained abutments) showed the least strain in presence of rotation errors.

Entities:  

Mesh:

Year:  2000        PMID: 11168237     DOI: 10.1034/j.1600-0501.2000.011005448.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  14 in total

1.  Stress distribution of multiple implant-supported prostheses: Photoelastic and strain gauge analyses of external hexagon and morse taper connections.

Authors:  Ana-Beatriz-Bueno-Carlini Bittencourt; Erica-de Oliveira-Paiva Rezende; Marcio Campaner; Sandro-Basso Bitencourt; Daniela-Micheline Dos Santos; Aldiéris-Alves Pesqueira; Marcelo-Coelho Goiato
Journal:  J Clin Exp Dent       Date:  2022-03-01

2.  The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns.

Authors:  Reza Derafshi; Mitra Farzin; Masoumeh Taghva; Hossein Heidary; Berivan Atashkar
Journal:  J Dent (Shiraz)       Date:  2015-03

3.  Three-dimensional accuracy of different correction methods for cast implant bars.

Authors:  Ji-Yung Kwon; Chang-Whe Kim; Young-Jun Lim; Ho-Beom Kwon; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

4.  Volumetric Changes in Morse Taper Connections After Implant Placement in Dense Bone. In-Vitro Study.

Authors:  Georgios E Romanos; Rafael Arcesio Delgado-Ruiz; Ana I Nicolas-Silvente
Journal:  Materials (Basel)       Date:  2020-05-16       Impact factor: 3.623

5.  Deformation of the Internal Connection of Narrow Implants after Insertion in Dense Bone: An in Vitro Study.

Authors:  Rafael Delgado-Ruiz; Ana Nicolas Silvente; Georgios Romanos
Journal:  Materials (Basel)       Date:  2019-06-06       Impact factor: 3.623

6.  A Special Design to Facilitate Retrieval of Cement-Retained Zirconia-Based Implant-Supported Restorations.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Masumeh Taghva
Journal:  J Dent (Shiraz)       Date:  2021-06

7.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

8.  Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses.

Authors:  Mi-Young Lee; Seong-Joo Heo; Eun-Jin Park; Ji-Man Park
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

9.  Effect of tightening torque on the marginal adaptation of cement-retained implant-supported fixed dental prostheses.

Authors:  Jalil Ghanbarzadeh; Hossin Dashti; Reza Karamad; Marzieh Alikhasi; Mohammadreza Nakhaei
Journal:  Dent Res J (Isfahan)       Date:  2015 Jul-Aug

10.  Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study.

Authors:  Jae-Won Choi; Kyung-Hee Choi; Hee-Jin Chae; Sung-Ki Chae; Eun-Bin Bae; Jin-Ju Lee; So-Hyoun Lee; Chang-Mo Jeong; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2018-04-06       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.