Literature DB >> 15359161

Screw loosening for standard and wide diameter implants in partially edentulous cases: 3- to 7-year longitudinal data.

Sang-Choon Cho1, Paula-Naomi Small, Nicolas Elian, Dennis Tarnow.   

Abstract

Screw loosening is considered to be a common problem with both screw-retained and cemented implant restorations. A wider abutment platform, as well as using a torque driver to tighten specifically designed screws may help prevent this loosening. However, there has been no clinical study evaluating either of these. To longitudinally compare the frequency of screw loosening in standard diameter, (3.75 and 4.0 mm) implant supported prostheses to that of wide diameter, (5.0 and 6.0 mm) implant supported prostheses that were hand tightened, and to evaluate whether using a torque driver would minimize or prevent this problem, if screw loosening occurred. A total of 213 dental implants in 106 patients were included in this prospective longitudinal study. Of the implants 68 were wide diameter and 145 were standard diameter implants. Wide diameter implants showed 5.8% screw loosening, while standard diameter implants showed 14.5% screw loosening after insertion with only hand torquing. When these loose screws were tightened with a torque driver, there was no more loosening of screws. Within the limitations of this study, the wide diameter implants tested showed less screw loosening than the standard diameter implants when hand torqued. Additionally, within the scope of our study, using a torque driver to tighten the screws with the recommended force prevented this loosening from reoccurring in all cases.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15359161     DOI: 10.1097/01.id.0000140459.87333.f8

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  9 in total

Review 1.  Management of perishing implants with abutment screw fracture - A systematic review.

Authors:  Soja Raju; Vivek V Nair; Harsha Kumar Karunakaran; Noxy George Manjuran
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

2.  Factors associated with abutment screw loosening in single implant supported crowns: A cross-sectional study.

Authors:  S M Londhe; E Mahesh Gowda; V B Mandlik; M P Shashidhar
Journal:  Med J Armed Forces India       Date:  2018-10-10

3.  Comparison of access-hole filling materials for screw retained implant prostheses: 12-month in vivo study.

Authors:  Rémy Tanimura; Shiro Suzuki
Journal:  Int J Implant Dent       Date:  2017-05-05

4.  Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study.

Authors:  Ki-Young Lee; Kyung Su Shin; Ji-Hye Jung; Hye-Won Cho; Kyung-Hwan Kwon; Yu-Lee Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2020-04-30

5.  Comparison of Mechanical Resistance to Maximal Torsion Stress in Original and Nonoriginal or Compatible Prosthetic Implant Screws: An In Vitro Study.

Authors:  António Sérgio Silva; José Manuel Mendes; Tiago Araújo; Carlos Aroso; Pedro Barreiros
Journal:  Int J Dent       Date:  2021-12-02

Review 6.  Technical complications of implant-causes and management: A comprehensive review.

Authors:  Swati Gupta; Hemant Gupta; Amrit Tandan
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

7.  Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study.

Authors:  Hadi Mokhtarpour; Reza Eftekhar Ashtiani; Minoo Mahshid; Farhad Tabatabaian; Marzieh Alikhasi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-08-17

8.  Comparative study of abutment screw loosening with or without adhesive material.

Authors:  Mahnaz Arshad; Gholamreza Shirani; Sina Refoua; Mohammadreza Rahimi Yeganeh
Journal:  J Adv Prosthodont       Date:  2017-04-06       Impact factor: 1.904

9.  Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading.

Authors:  Behnaz Ebadian; Amirhossein Fathi; Saba Khodadad
Journal:  Int J Dent       Date:  2021-07-19
  9 in total