Literature DB >> 15248882

Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures.

Siegfried M Heckmann1, Matthias Karl, Manfred G Wichmann, Werner Winter, Friedrich Graef, Thomas D Taylor.   

Abstract

It is generally assumed that passively fitting superstructures are a prerequisite for long-lasting implant success. In the study presented, the strain development of three-unit implant fixed partial dentures (FPDs) was evaluated at the bone surrounding the implant and on the superstructure using a strain gauge technique. Six groups of three-unit FPDs representing the commonly used techniques of bridge fabrication were investigated with 10 samples each, in order to quantify the influence of impression technique, mode of fabrication and retention mechanism on superstructure fit. Two ITI implants (Straumann, Waldenburg, Switzerland) were anchored in a measurement model according to a real-life patient situation and strain gauges were fixed mesially and distally adjacent to the implants and on the bridge pontics. The developing strains were recorded during cement setting and screw fixation. For statistical analysis, multivariate two sample tests were performed setting the level of significance at P=0.1. None of the investigated bridges revealed a truly passive fit without strains occurring. About 50% of the measured strains were found to be due to impression taking and model fabrication, whereas the remaining 50% were related to laboratory inaccuracies. The two impression techniques used did not reveal any significant differences in terms of precision. Both modes of fixation--i.e. cement and screw retention--provoked equally high stress levels. In the fabrication of screw-retained FPDs, similar results were obtained from the use of burn-out plastic copings and the technique of casting wax moulds to premachined components. Bonding bridge frames onto gold cylinders directly on the implants significantly reduces strain development.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15248882     DOI: 10.1111/j.1600-0501.2004.01027.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  17 in total

1.  Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure.

Authors:  Maria Menini; Paolo Setti; Francesco Pera; Paolo Pera; Paolo Pesce
Journal:  Clin Oral Investig       Date:  2017-09-30       Impact factor: 3.573

2.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

3.  Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses.

Authors:  Byoung-Sup Sohn; Seong-Joo Heo; Jai-Young Koak; Seong-Kyun Kim; Su-Young Lee
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

4.  Precision of fit of titanium and cast implant frameworks using a new matching formula.

Authors:  Marianella Sierraalta; Jose L Vivas; Michael E Razzoog; Rui-Feng Wang
Journal:  Int J Dent       Date:  2012-04-08

5.  Knowledge and practice of implant-retained restorations among dental students in Saudi Arabia.

Authors:  Fahim Vohra; Altaf Hussain Shah; Mohammad Sohail Zafar; Zaheer Kola
Journal:  Pak J Med Sci       Date:  2015 Jul-Aug       Impact factor: 1.088

6.  Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis.

Authors:  Luis Gustavo Oliveira de Vasconcellos; Renato Sussumu Nishioka; Luana Marotta Reis de Vasconcellos; Lea Nogueira Braulino de Melo Nishioka
Journal:  J Appl Oral Sci       Date:  2011 Nov-Dec       Impact factor: 2.698

7.  Impression of multiple implants using photogrammetry: description of technique and case presentation.

Authors:  David Peñarrocha-Oltra; Rubén Agustín-Panadero; Leticia Bagán; Beatriz Giménez; María Peñarrocha
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-07-01

8.  An alternative technique for fabrication of frameworks in an immediate loading implant fixed mandibular prosthesis.

Authors:  André Gustavo Paleari; Cristina Dupim Presoto; Juliano Alencar Vasconcelos; José Maurício Dos Santos Nunes Reis; Lígia Antunes Pereira Pinelli; Regina Helena Barbosa Tavares da Silva; Cristiane Campos Costa Quishida
Journal:  Case Rep Dent       Date:  2015-01-05

9.  Accuracy of Proximal and Occlusal Contacts of Single Implant Crowns Fabricated Using Different Digital Scan Methods: An In Vitro Study.

Authors:  Xi Ren; Keunbada Son; Kyu-Bok Lee
Journal:  Materials (Basel)       Date:  2021-05-26       Impact factor: 3.623

10.  Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses.

Authors:  Mi-Young Lee; Seong-Joo Heo; Eun-Jin Park; Ji-Man Park
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.