Literature DB >> 9421671

Implant screw mechanics.

E A McGlumphy1, D A Mendel, J A Holloway.   

Abstract

Osseointegrated implant support of dental restorations continues to be a popular option for the contemporary patient with missing natural dentition. This article focuses on the two most frequently used methods for attaching final prostheses to endosseous implants. The authors offer practical solutions for minimizing implant screw loosening and describe the factors involved in maintaining stable screw joint assembly.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9421671

Source DB:  PubMed          Journal:  Dent Clin North Am        ISSN: 0011-8532


  36 in total

1.  Removal torque evaluation of three different abutment screws for single implant restorations after mechanical cyclic loading.

Authors:  T Paepoemsin; P A Reichart; P Chaijareenont; F P Strietzel; P Khongkhunthian
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

2.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

3.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

4.  Evaluation the loosening of abutment screws in fluid contamination: an in vitro study.

Authors:  Fei Sun; Wei Cheng; Bao-Hong Zhao; Gui-Qiu Song; Zeng Lin
Journal:  Sci Rep       Date:  2022-06-24       Impact factor: 4.996

5.  Experimental study on the factors affecting torque of beam-type implant torque wrenches.

Authors:  Hiroki Shiba; Yuji Sato; Junichi Furuya; Tokiko Osawa; Akio Isobe; Myu Hayashi; Noboru Kitagawa
Journal:  BMC Oral Health       Date:  2021-07-15       Impact factor: 2.757

6.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

7.  A Special Design to Facilitate Retrieval of Cement-Retained Zirconia-Based Implant-Supported Restorations.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Masumeh Taghva
Journal:  J Dent (Shiraz)       Date:  2021-06

8.  The effect of aging on the accuracy of new friction-style mechanical torque limiting devices for dental implants.

Authors:  Aboulfazl Saboury; Seyed Jalil Sadr; Ali Fayaz; Minoo Mahshid
Journal:  J Dent (Tehran)       Date:  2013-01-31

9.  Evaluation of the accuracy and related factors of the mechanical torque-limiting device for dental implants.

Authors:  Mahmood Kazemi; Ahmad Rohanian; Abbas Monzavi; Mohammad Sadegh Nazari
Journal:  J Dent (Tehran)       Date:  2013-03-31

10.  The effect of steam sterilization on the accuracy of spring-style mechanical torque devices for dental implants.

Authors:  Minoo Mahshid; Aboulfazl Saboury; Ali Fayaz; Seyed Jalil Sadr; Friedrich Lampert; Maziar Mir
Journal:  Clin Cosmet Investig Dent       Date:  2012-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.