Literature DB >> 1843491

Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study.

T Jemt1, W R Laney, D Harris, P J Henry, P H Krogh, G Polizzi, G A Zarb, I Herrmann.   

Abstract

One hundred seven dental implants were inserted to support single tooth restorations in 92 patients participating in a prospective multicenter investigation. Only three implants (2.8%) were lost after 1 year of clinical function. Most of the remaining restorations were esthetically successful by using modified components. The gingival condition was healthy around the single crowns and coincided well with the clinical situation around the permanent teeth. The most obvious problem experienced during the first year was related to loose abutment screws. Twenty-six percent of the screws retaining crowns were retightened during the observation period, but the frequency of loose screws had a tendency to decrease as the study progressed.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1843491

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  16 in total

1.  Local complications in dental implant surgery: prevention and treatment.

Authors:  S Annibali; M Ripari; G LA Monaca; F Tonoli; M P Cristalli
Journal:  Oral Implantol (Rome)       Date:  2008-06-16

Review 2.  Pre- and post-operative management of dental implant placement. Part 2: management of early-presenting complications.

Authors:  G Bryce; D I Bomfim; G S Bassi
Journal:  Br Dent J       Date:  2014-08       Impact factor: 1.626

3.  Cleft lip and palate cause large variations in size and location of the posterior superior alveolar canal.

Authors:  Eymi Valery Cazas Duran de Gittins; Renato Yassutaka Faria Yaedú; José Roberto Pereira Lauris; Cassia Maria Fischer Rubira; Bruna Stuchi Centurion Pagin; Izabel Regina Fischer Rubira-Bullen
Journal:  Clin Oral Investig       Date:  2021-01-08       Impact factor: 3.573

4.  Sinking and fit of abutment of locking taper implant system.

Authors:  Seung-Jin Moon; Hee-Jung Kim; Mee-Kyoung Son; Chae-Heon Chung
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

5.  Evaluation the loosening of abutment screws in fluid contamination: an in vitro study.

Authors:  Fei Sun; Wei Cheng; Bao-Hong Zhao; Gui-Qiu Song; Zeng Lin
Journal:  Sci Rep       Date:  2022-06-24       Impact factor: 4.996

6.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

7.  Factors associated with abutment screw loosening in single implant supported crowns: A cross-sectional study.

Authors:  S M Londhe; E Mahesh Gowda; V B Mandlik; M P Shashidhar
Journal:  Med J Armed Forces India       Date:  2018-10-10

8.  Survey of Screw-Retained versus Cement-Retained Implant Restorations in Saudi Arabia.

Authors:  Alaa Makke; Abdulwahed Homsi; Montaha Guzaiz; Abdulrahman Almalki
Journal:  Int J Dent       Date:  2017-10-30

9.  Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

Authors:  Woong-Rae Cho; Yoon-Hyuk Huh; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

10.  Angulated Implants for Fabrication of Implant Supported Fixed Partial Denture in the Maxilla.

Authors:  Nicholas Egbert; Swati Ahuja; Audrey Selecman; Russell Wicks
Journal:  J Dent (Shiraz)       Date:  2017-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.