Literature DB >> 22595497

Establishment of CT diagnostic reference levels in Ireland.

S J Foley1, M F McEntee, L A Rainford.   

Abstract

OBJECTIVE: To propose Irish CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations.
METHODS: A pilot study investigated the most frequent CT examinations. 40 CT sites were then asked to complete a survey booklet to allow the recording of CT parameters for each of 9 CT examinations during a 12-week period. Dose data [CT volume index (CTDI(vol)) and dose-length product (DLP)] on a minimum of 10 average-sized patients in each category were recorded to calculate a mean site CTDI(vol) and DLP value. The rounded 75th percentile was used to calculate a DRL for each site and the country by compiling all results.
RESULTS: are compared with international DRL data. Results Data were collected for 3305 patients. 30 sites responded with data for 34 scanners, representing 54% of the national total. All equipment had multislice capability (2-128 slices). DRLs are proposed using CTDI(vol) (mGy) and DLP (mGy cm) for CT head (66/58 and 940, respectively), sinuses (16 and 210, respectively), cervical spine (19 and 420, respectively), thorax (9/11 and 390, respectively), high resolution CT (7 and 280, respectively), CT pulmonary angiography (13 and 430, respectively), multiphase abdomen (13 and 1120, respectively), routine abdomen/pelvis (12 and 600, respectively) and trunk examinations (10/12 and 850, respectively). These values are lower than current DRLs and comparable to other international studies. Wide variations in mean doses are noted across sites.
CONCLUSIONS: Baseline figures for Irish CT DRLs are provided on the most frequently performed CT examinations. The variations in dose between CT departments as well as between identical scanners suggest a large potential for optimisation of examinations.

Entities:  

Mesh:

Year:  2012        PMID: 22595497      PMCID: PMC3474022          DOI: 10.1259/bjr/15839549

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  12 in total

1.  Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels.

Authors:  R Treier; A Aroua; F R Verdun; E Samara; A Stuessi; Ph R Trueb
Journal:  Radiat Prot Dosimetry       Date:  2010-10-06       Impact factor: 0.972

2.  Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania.

Authors:  J E Ngaile; P Msaki; R Kazema
Journal:  J Radiol Prot       Date:  2006-05-26       Impact factor: 1.394

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

5.  Radiological protection and safety in medicine. A report of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  1996

6.  CT scanner dosimetry.

Authors:  P C Shrimpton; S Edyvean
Journal:  Br J Radiol       Date:  1998-01       Impact factor: 3.039

7.  National survey of doses from CT in the UK: 2003.

Authors:  P C Shrimpton; M C Hillier; M A Lewis; M Dunn
Journal:  Br J Radiol       Date:  2006-12       Impact factor: 3.039

8.  Projected cancer risks from computed tomographic scans performed in the United States in 2007.

Authors:  Amy Berrington de González; Mahadevappa Mahesh; Kwang-Pyo Kim; Mythreyi Bhargavan; Rebecca Lewis; Fred Mettler; Charles Land
Journal:  Arch Intern Med       Date:  2009-12-14

Review 9.  Strategies for CT radiation dose optimization.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Leena M Hamberg; Michael A Blake; Jo-Anne Shepard; Sanjay Saini
Journal:  Radiology       Date:  2004-01-22       Impact factor: 11.105

Review 10.  Cancer risks from diagnostic radiology.

Authors:  E J Hall; D J Brenner
Journal:  Br J Radiol       Date:  2008-05       Impact factor: 3.039

View more
  29 in total

1.  Survey of volume CT dose index in Japan in 2014.

Authors:  Y Matsunaga; A Kawaguchi; K Kobayashi; Y Kinomura; M Kobayashi; Y Asada; K Minami; S Suzuki; K Chida
Journal:  Br J Radiol       Date:  2015-06-04       Impact factor: 3.039

2.  Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.

Authors:  Federica Palorini; Daniela Origgi; Claudio Granata; Domenica Matranga; Sergio Salerno
Journal:  Eur Radiol       Date:  2014-02       Impact factor: 5.315

3.  CT chest abdomen pelvis doses in Scotland: has the DRL had its day?

Authors:  D G Sutton; S McVey; D Gentle; A J Hince; N MacDonald; S McCallum
Journal:  Br J Radiol       Date:  2014-06-27       Impact factor: 3.039

Review 4.  Artificial intelligence in diagnostic imaging: impact on the radiography profession.

Authors:  Maryann Hardy; Hugh Harvey
Journal:  Br J Radiol       Date:  2019-12-16       Impact factor: 3.039

5.  Local clinical diagnostic reference levels for chest and abdomen CT examinations in adults as a function of body mass index and clinical indication: a prospective multicenter study.

Authors:  Hugues Brat; Federica Zanca; Stéphane Montandon; Damien Racine; Benoit Rizk; Eric Meicher; Dominique Fournier
Journal:  Eur Radiol       Date:  2019-05-29       Impact factor: 5.315

6.  Patient doses from CT examinations in Turkey.

Authors:  Gökçe Kaan Ataç; Aydın Parmaksız; Tolga İnal; Emine Bulur; Figen Bulgurlu; Tolga Öncü; Sadi Gündoğdu
Journal:  Diagn Interv Radiol       Date:  2015 Sep-Oct       Impact factor: 2.630

7.  National diagnostic reference level initiative for computed tomography examinations in Kenya.

Authors:  Geoffrey K Korir; Jeska S Wambani; Ian K Korir; Mark A Tries; Patrick K Boen
Journal:  Radiat Prot Dosimetry       Date:  2015-03-19       Impact factor: 0.972

8.  Establishment of national diagnostic reference levels for breast cancer CT protocols in radiation therapy.

Authors:  Sean O' Connor; Orla Mc Ardle; Laura Mullaney
Journal:  Br J Radiol       Date:  2016-07-25       Impact factor: 3.039

9.  Diagnostic reference ranges and the American College of Radiology Dose Index Registry: the pediatric experience.

Authors:  Marilyn J Goske
Journal:  Pediatr Radiol       Date:  2014-10-11

10.  Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function.

Authors:  Yasunori Nagayama; Shota Tanoue; Akinori Tsuji; Joji Urata; Mitsuhiro Furusawa; Seitaro Oda; Takeshi Nakaura; Daisuke Utsunomiya; Eri Yoshida; Morikatsu Yoshida; Masafumi Kidoh; Machiko Tateishi; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2018-03-02       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.