Literature DB >> 17213302

National survey of doses from CT in the UK: 2003.

P C Shrimpton1, M C Hillier, M A Lewis, M Dunn.   

Abstract

A review of patient doses from CT examinations in the UK for 2003 has been conducted on the basis of data received from over a quarter of all UK scanners, of which 37% had multislice capability. Questionnaires were employed to collect scan details both for the standard protocols established at each scanner for 12 common types of CT examination on adults and children, and for samples of individual patients. This information was combined with published scanner-specific CT dose index (CTDI) coefficients to estimate values of the standard dose indices CTDI(w) and CTDI(vol) for each scan sequence. Knowledge of each scan length allowed assessment of the dose-length product (DLP) for each examination, from which effective doses were then estimated. When compared with a previous UK survey for 1991, wide variations were still apparent between CT centres in the doses for standard protocols. The mean UK doses for adult patients were in general lower by up to 50% than those for 1991, although doses were slightly higher for multislice (4+) (MSCT) relative to single slice (SSCT) scanners. Values of CTDI(vol) for MSCT were broadly similar to European survey data for 2001. The third quartile values of these dose distributions have been used to derive UK national reference doses for examinations on adults (separately for SSCT and MSCT) and children as initial tools for promoting patient protection. The survey has established the PREDICT (Patient Radiation Exposure and Dose in CT) database as a sustainable national resource for monitoring dose trends in CT through the ongoing collation of further survey data.

Entities:  

Mesh:

Year:  2006        PMID: 17213302     DOI: 10.1259/bjr/93277434

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  157 in total

1.  Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography: design and implementation of the CORE320 multicenter, multinational diagnostic study.

Authors:  Andrea L Vavere; Gregory G Simon; Richard T George; Carlos E Rochitte; Andrew E Arai; Julie M Miller; Marcello Di Carli; Armin Arbab-Zadeh; Armin A Zadeh; Marc Dewey; Hiroyuki Niinuma; Roger Laham; Frank J Rybicki; Joanne D Schuijf; Narinder Paul; John Hoe; Sachio Kuribyashi; Hajime Sakuma; Cesar Nomura; Tan Swee Yaw; Klaus F Kofoed; Kunihiro Yoshioka; Melvin E Clouse; Jeffrey Brinker; Christopher Cox; Joao A C Lima
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-11-12

2.  Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection.

Authors:  A Korn; M Fenchel; B Bender; S Danz; T K Hauser; D Ketelsen; T Flohr; C D Claussen; M Heuschmid; U Ernemann; H Brodoefel
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-27       Impact factor: 3.825

3.  Accuracy of automated attenuation-based 3-dimensional segmentation: in the analysis of left ventricular function compared with magnetic resonance imaging.

Authors:  Harald Brodoefel; Ilias Tsiflikas; Ulrich Kramer; Nina Lang; Anja Reimann; Christoph Burgstahler; Claus D Claussen; Martin Heuschmid
Journal:  Tex Heart Inst J       Date:  2012

4.  Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008.

Authors:  P Catuzzo; S Aimonetto; F Zenone; G Fanelli; P Marchisio; T Meloni; M Pasquino; S Tofani
Journal:  Br J Radiol       Date:  2010-12       Impact factor: 3.039

Review 5.  First and second branchial arch syndromes: multimodality approach.

Authors:  Elodie Senggen; Tarek Laswed; Jean-Yves Meuwly; Leonor Alamo Maestre; Bertrand Jaques; Reto Meuli; François Gudinchet
Journal:  Pediatr Radiol       Date:  2010-10-06

6.  Role of preoperative 3D CT reconstruction for evaluation of patients with esophageal atresia and tracheoesophageal fistula.

Authors:  Santosh Kumar Mahalik; Kushaljeet Singh Sodhi; K L Narasimhan; K L N Rao
Journal:  Pediatr Surg Int       Date:  2012-06-22       Impact factor: 1.827

7.  Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan.

Authors:  Yasutaka Takei; Osamu Miyazaki; Kosuke Matsubara; Yoshiya Shimada; Yoshihisa Muramatsu; Keiichi Akahane; Keisuke Fujii; Shoichi Suzuki; Kichiro Koshida
Journal:  Pediatr Radiol       Date:  2016-02

8.  CT diagnostic reference levels: are they appropriately computed?

Authors:  Thibault Vanaudenhove; Alain Van Muylem; Nigel Howarth; Pierre Alain Gevenois; Denis Tack
Journal:  Eur Radiol       Date:  2019-04-08       Impact factor: 5.315

9.  Detection of ischaemic myocardial lesions with coronary CT angiography and adenosine-stress dynamic perfusion imaging using a 128-slice dual-source CT: diagnostic performance in comparison with cardiac MRI.

Authors:  S M Kim; J-H Choi; S-A Chang; Y H Choe
Journal:  Br J Radiol       Date:  2013-10-04       Impact factor: 3.039

10.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer.

Authors:  Rebecca Smith-Bindman; Jafi Lipson; Ralph Marcus; Kwang-Pyo Kim; Mahadevappa Mahesh; Robert Gould; Amy Berrington de González; Diana L Miglioretti
Journal:  Arch Intern Med       Date:  2009-12-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.