Literature DB >> 25304712

Diagnostic reference ranges and the American College of Radiology Dose Index Registry: the pediatric experience.

Marilyn J Goske1.   

Abstract

CT scans are powerful tools used in the care of pediatric patients daily. Yet the increased use of CT warrants careful monitoring. This article defines diagnostic reference levels and how they can be used to guide practice. Once a facility has adapted its techniques and protocols to fall within diagnostic reference levels or target values, the facility can expand its quality-improvement efforts to include a new concept, diagnostic reference ranges (DRRs). DRRs take into account the subjective image quality of the examination and provide a minimum estimated patient dose, below which accurate interpretation of an image might be difficult, and an upper estimated dose, above which the patient dose may be higher than necessary. This paper also describes how the American College of Radiology Dose Index Registry can be used by a facility as a continuous quality improvement tool to monitor and manage appropriate patient dose.

Entities:  

Mesh:

Year:  2014        PMID: 25304712     DOI: 10.1007/s00247-014-3030-0

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  17 in total

1.  Diagnostic reference levels from the ACR CT Accreditation Program.

Authors:  Cynthia McCollough; Theresa Branham; Vince Herlihy; Mythreyi Bhargavan; Lavonne Robbins; Krista Bush; Michael McNitt-Gray; J Thomas Payne; Tom Ruckdeschel; Doug Pfeiffer; Dianna Cody; Robert Zeman
Journal:  J Am Coll Radiol       Date:  2011-11       Impact factor: 5.532

2.  Radiation exposure in CT: what is the professionally responsible approach?

Authors:  Stephen J Golding
Journal:  Radiology       Date:  2010-06       Impact factor: 11.105

Review 3.  Managing radiation use in medical imaging: a multifaceted challenge.

Authors:  Hedvig Hricak; David J Brenner; S James Adelstein; Donald P Frush; Eric J Hall; Roger W Howell; Cynthia H McCollough; Fred A Mettler; Mark S Pearce; Orhan H Suleiman; James H Thrall; Louis K Wagner
Journal:  Radiology       Date:  2010-12-16       Impact factor: 11.105

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

5.  Establishment of CT diagnostic reference levels in Ireland.

Authors:  S J Foley; M F McEntee; L A Rainford
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

6.  National Council on Radiation Protection and Measurements report shows substantial medical exposure increase.

Authors:  David A Schauer; Otha W Linton
Journal:  Radiology       Date:  2009-11       Impact factor: 11.105

7.  Patient-specific radiation dose and cancer risk for pediatric chest CT.

Authors:  Xiang Li; Ehsan Samei; W Paul Segars; Gregory M Sturgeon; James G Colsher; Donald P Frush
Journal:  Radiology       Date:  2011-04-05       Impact factor: 11.105

8.  The European Directive on health protection of individuals against the dangers of ionising radiation in relation to medical exposures (97/43/EURATOM).

Authors:  D Teunen
Journal:  J Radiol Prot       Date:  1998-06       Impact factor: 1.394

9.  Diagnostic reference levels for thorax X-ray examinations of paediatric patients.

Authors:  T Kiljunen; H Järvinen; S Savolainen
Journal:  Br J Radiol       Date:  2007-06       Impact factor: 3.039

10.  Diagnostic reference ranges for pediatric abdominal CT.

Authors:  Marilyn J Goske; Keith J Strauss; Laura P Coombs; Keith E Mandel; Alexander J Towbin; David B Larson; Michael J Callahan; Kassa Darge; Daniel J Podberesky; Donald P Frush; Sjirk J Westra; Jeffrey S Prince
Journal:  Radiology       Date:  2013-03-19       Impact factor: 11.105

View more