Literature DB >> 18082557

The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

.   

Abstract

These revised Recommendations for a System of Radiological Protection formally replace the Commission's previous, 1990, Recommendations; and update, consolidate, and develop the additional guidance on the control of exposure from radiation sources issued since 1990. Thus, the present Recommendations update the radiation and tissue weighting factors in the quantities equivalent and effective dose and update the radiation detriment, based on the latest available scientific information of the biology and physics of radiation exposure. They maintain the Commission's three fundamental principles of radiological protection, namely justification, optimisation, and the application of dose limits, clarifying how they apply to radiation sources delivering exposure and to individuals receiving exposure. The Recommendations evolve from the previous process-based protection approach using practices and interventions by moving to an approach based on the exposure situation. They recognise planned, emergency, and existing exposure situations, and apply the fundamental principles of justification and optimisation of protection to all of these situations. They maintain the Commission's current individual dose limits for effective dose and equivalent dose from all regulated sources in planned exposure situations. They reinforce the principle of optimisation of protection, which should be applicable in a similar way to all exposure situations, subject to the following restrictions on individual doses and risks; dose and risk constraints for planned exposure situations, and reference levels for emergency and existing exposure situations. The Recommendations also include an approach for developing a framework to demonstrate radiological protection of the environment.

Mesh:

Year:  2007        PMID: 18082557     DOI: 10.1016/j.icrp.2007.10.003

Source DB:  PubMed          Journal:  Ann ICRP        ISSN: 0146-6453


  1097 in total

1.  Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring.

Authors:  Aaron Sodickson; Graham I Warden; Cameron E Farkas; Ichiro Ikuta; Luciano M Prevedello; Katherine P Andriole; Ramin Khorasani
Journal:  Radiology       Date:  2012-06-05       Impact factor: 11.105

2.  Radiation doses for pediatric nuclear medicine studies: comparing the North American consensus guidelines and the pediatric dosage card of the European Association of Nuclear Medicine.

Authors:  Frederick D Grant; Michael J Gelfand; Laura A Drubach; S Ted Treves; Frederic H Fahey
Journal:  Pediatr Radiol       Date:  2014-11-01

3.  Two-Phase Contrast Injection Protocol for Pediatric Cardiac Computed Tomography in Children with Congenital Heart Disease.

Authors:  Naoki Fukuyama; Akira Kurata; Naoto Kawaguchi; Ryo Tashiro; Takashi Higaki; Takahiro Yokoi; Yuki Tanabe; Hikaru Nishiyama; Toshihide Itoh; Teruhito Kido; Masao Miyagawa; Teruhito Mochizuki
Journal:  Pediatr Cardiol       Date:  2017-12-06       Impact factor: 1.655

4.  Lauriston S. Taylor Lecture on radiation protection and measurements: what makes particle radiation so effective?

Authors:  Eleanor A Blakely
Journal:  Health Phys       Date:  2012-11       Impact factor: 1.316

5.  Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography.

Authors:  John B Ludlow; Cameron Walker
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-12       Impact factor: 2.650

Review 6.  Current knowledge on tumour induction by computed tomography should be carefully used.

Authors:  Cristian Candela-Juan; Alegría Montoro; Enrique Ruiz-Martínez; Juan Ignacio Villaescusa; Luis Martí-Bonmatí
Journal:  Eur Radiol       Date:  2013-11-27       Impact factor: 5.315

7.  Standardization and optimization of CT protocols to achieve low dose.

Authors:  Sigal Trattner; Gregory D N Pearson; Cynthia Chin; Dianna D Cody; Rajiv Gupta; Christopher P Hess; Mannudeep K Kalra; James M Kofler; Mayil S Krishnam; Andrew J Einstein
Journal:  J Am Coll Radiol       Date:  2014-03       Impact factor: 5.532

Review 8.  Coronary CT angiography with prospective ECG-triggering: an effective alternative to invasive coronary angiography.

Authors:  Zhonghua Sun
Journal:  Cardiovasc Diagn Ther       Date:  2012-03

Review 9.  Diagnostic accuracy of low-dose CT compared with abdominal radiography in non-traumatic acute abdominal pain: prospective study and systematic review.

Authors:  Muhammed Alshamari; Eva Norrman; Mats Geijer; Kjell Jansson; Håkan Geijer
Journal:  Eur Radiol       Date:  2015-09-18       Impact factor: 5.315

10.  Human dental age estimation using third molar developmental stages: does a Bayesian approach outperform regression models to discriminate between juveniles and adults?

Authors:  P W Thevissen; S Fieuws; G Willems
Journal:  Int J Legal Med       Date:  2009-02-24       Impact factor: 2.686

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.