Literature DB >> 25790825

National diagnostic reference level initiative for computed tomography examinations in Kenya.

Geoffrey K Korir1, Jeska S Wambani2, Ian K Korir3, Mark A Tries4, Patrick K Boen2.   

Abstract

The purpose of this study was to estimate the computed tomography (CT) examination frequency, patient radiation exposure, effective doses and national diagnostic reference levels (NDRLs) associated with CT examinations in clinical practice. A structured questionnaire-type form was developed for recording examination frequency, scanning protocols and patient radiation exposure during CT procedures in fully equipped medical facilities across the country. The national annual number of CT examinations per 1000 people was estimated to be 3 procedures. The volume-weighted CT dose index, dose length product, effective dose and NDRLs were determined for 20 types of adult and paediatric CT examinations. Additionally, the CT annual collective effective dose and effective dose per capita were approximated. The radiation exposure during CT examinations was broadly distributed between the facilities that took part in the study. This calls for a need to develop and implement diagnostic reference levels as a standardisation and optimisation tool for the radiological protection of patients at all the CT facilities nationwide.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 25790825      PMCID: PMC4884875          DOI: 10.1093/rpd/ncv020

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  29 in total

Review 1.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

2.  Establishment of CT diagnostic reference levels in Ireland.

Authors:  S J Foley; M F McEntee; L A Rainford
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

3.  Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital.

Authors:  J S Wambani; G K Korir; I K Korir; S Kilaha
Journal:  Radiat Prot Dosimetry       Date:  2012-10-22       Impact factor: 0.972

4.  Patient doses in multi-slice CT and the importance of optimisation.

Authors:  J C P Heggie
Journal:  Australas Phys Eng Sci Med       Date:  2005-06       Impact factor: 1.430

5.  CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland.

Authors:  Francis R Verdun; Daniel Gutierrez; John Paul Vader; Abbas Aroua; Leonor Trinidad Alamo-Maestre; François Bochud; François Gudinchet
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

6.  Solid cancer incidence in atomic bomb survivors: 1958-1998.

Authors:  D L Preston; E Ron; S Tokuoka; S Funamoto; N Nishi; M Soda; K Mabuchi; K Kodama
Journal:  Radiat Res       Date:  2007-07       Impact factor: 2.841

7.  Patient radiation dose at CT urography and conventional urography.

Authors:  Richard D Nawfel; Philip F Judy; A Robert Schleipman; Stuart G Silverman
Journal:  Radiology       Date:  2004-07       Impact factor: 11.105

8.  Patient doses in CT examinations in 18 countries: initial results from International Atomic Energy Agency projects.

Authors:  W E Muhogora; N A Ahmed; A Beganovic; A Benider; O Ciraj-Bjelac; V Gershan; E Gershkevitsh; E Grupetta; M H Kharita; N Manatrakul; M Milakovic; K Ohno; L Ben Omrane; J Ptacek; C Schandorf; M S Shabaan; D Stoyanov; N Toutaoui; J S Wambani; M M Rehani
Journal:  Radiat Prot Dosimetry       Date:  2009-08-17       Impact factor: 0.972

9.  Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates.

Authors:  Jörg Hausleiter; Tanja Meyer; Martin Hadamitzky; Ester Huber; Maria Zankl; Stefan Martinoff; Adnan Kastrati; Albert Schömig
Journal:  Circulation       Date:  2006-03-06       Impact factor: 29.690

Review 10.  CT radiation dose optimization and estimation: an update for radiologists.

Authors:  Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

View more
  5 in total

Review 1.  Review of the current status of radiation protection in diagnostic radiology in Africa.

Authors:  Wilbroad Muhogora; Madan M Rehani
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-12

2.  Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels.

Authors:  Geoffrey Erem; Faith Ameda; Caroline Otike; William Olwit; Aloysius G Mubuuke; Cyril Schandorf; Akisophel Kisolo; Michael G Kawooya
Journal:  BMC Med Imaging       Date:  2022-06-11       Impact factor: 2.795

3.  An audit of radiation doses received by paediatric patients undergoing computed tomography investigations at academic hospitals in South Africa.

Authors:  Cornelis M van der Merwe; Nasreen Mahomed
Journal:  SA J Radiol       Date:  2020-10-16

4.  Radiology practice in sub-Saharan Africa during the COVID-19 outbreak: points to consider.

Authors:  Timothy Musila Mutala; Callen Kwamboka Onyambu; Angeline Anyona Aywak
Journal:  Pan Afr Med J       Date:  2020-09-07

5.  An Africa point of view on quality and safety in imaging.

Authors:  Michael G Kawooya; Harriet Nalubega Kisembo; Denis Remedios; Richard Malumba; Maria Del Rosario Perez; Taofeeq Ige; Francis Hasford; Joanna Kasznia Brown; Miriam Mikhail Lette; Boudjema Mansouri; Dina H Salama; Fozy Peer; Rose Nyabanda
Journal:  Insights Imaging       Date:  2022-03-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.