Literature DB >> 16738417

Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania.

J E Ngaile1, P Msaki, R Kazema.   

Abstract

Without the knowledge of reference dose levels (RDLs) from computed tomography (CT) examinations, the optimal dose to patients undergoing CT examinations cannot be realised. The aim of this study was therefore to assess the radiation dose levels from CT examinations according to reference dose quantities proposed by the European Commission (EC) guidelines. The dosimetric quantities proposed in the EC for CT are weighted CT dose index (CTDI(w)) for a single slice and dose-length product (DLP) for a complete examination. The RDLs from five common CT examinations were obtained from eight hospitals. The RDLs in terms of CTDI(w) and DLP were estimated from measurements of CTDI in standard phantoms using typical exposure parameters. Mean values of CTDI(w) for head and lumbar spine had a range of 25-77 and 18-47 mGy, respectively, while those for chest, abdomen and pelvis had a range of about 11-25 mGy, respectively. Mean values of DLP for head, chest and abdomen had a range of 610-1684, 496-992 and 717-1428 mGy cm, respectively, while those for lumbar spine and pelvis had a range of 200-382 and 526-1302 mGy cm, respectively. Wide variations of mean CTDI(w) and DLP values among hospitals observed for similar CT examinations were mainly attributed to the variations of CT scanning protocols and scanner types. The mean CTDI(w) values per examination for almost all hospitals were below proposed RDLs, while the mean DLP values per examination were almost all above the proposed RDLs for all except one hospital. These were mainly influenced by the large scan length used in Tanzanian hospitals. In order to achieve the required level of dose for establishment of the national RDLs, it was concluded that further investigation of optimization of scanning protocols is needed.

Entities:  

Mesh:

Year:  2006        PMID: 16738417     DOI: 10.1088/0952-4746/26/2/006

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  7 in total

1.  Establishment of CT diagnostic reference levels in Ireland.

Authors:  S J Foley; M F McEntee; L A Rainford
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

Review 2.  Adult patient radiation doses from non-cardiac CT examinations: a review of published results.

Authors:  I Pantos; S Thalassinou; S Argentos; N L Kelekis; G Panayiotakis; E P Efstathopoulos
Journal:  Br J Radiol       Date:  2011-01-25       Impact factor: 3.039

3.  National diagnostic reference level initiative for computed tomography examinations in Kenya.

Authors:  Geoffrey K Korir; Jeska S Wambani; Ian K Korir; Mark A Tries; Patrick K Boen
Journal:  Radiat Prot Dosimetry       Date:  2015-03-19       Impact factor: 0.972

4.  Radiation doses during computed tomography scan imaging in Hassan II Hospital, Agadir, Morocco.

Authors:  Slimane Semghouli; Bouchra Amaoui; Soukaina Wakrim
Journal:  Pan Afr Med J       Date:  2022-04-11

5.  Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels.

Authors:  Geoffrey Erem; Faith Ameda; Caroline Otike; William Olwit; Aloysius G Mubuuke; Cyril Schandorf; Akisophel Kisolo; Michael G Kawooya
Journal:  BMC Med Imaging       Date:  2022-06-11       Impact factor: 2.795

Review 6.  RSA in Spine: A Review.

Authors:  Ali Humadi; Sulaf Dawood; Klas Halldin; Brian Freeman
Journal:  Global Spine J       Date:  2017-07-28

7.  A Survey of Pediatric CT Protocols and Radiation Doses in South Korean Hospitals to Optimize the Radiation Dose for Pediatric CT Scanning.

Authors:  Jae-Yeon Hwang; Kyung-Hyun Do; Dong Hyun Yang; Young Ah Cho; Hye-Kyung Yoon; Jin Seong Lee; Hyun Jung Koo
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.