Literature DB >> 24121713

Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.

Federica Palorini, Daniela Origgi, Claudio Granata, Domenica Matranga, Sergio Salerno.   

Abstract

OBJECTIVES: To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population.
METHODS: This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest–abdomen–pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDIvol) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure.
RESULTS: The 75th percentiles of CTDIvol (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm, respectively; for chest, 15 mGy and 569 mGy cm; spine, 42 mGy and 888 mGy cm; cardiac, 7 mGy and 131 mGy cm for calcium score, and 61 mGy and 1,208 mGy cm for angiographic CT studies. High variability was present in the DLP of abdomen and CAP protocols, where multiphase examinations dominated (71 % and 73 % respectively): for abdomen, 18 mGy, with 555 and 920 mGy cm in abdomen and abdomen–pelvis acquisitions respectively; for CAP, 17 mGy, with 508, 850 and 1,200 mGy cm in abdomen, abdomen–pelvis and CAP acquisitions respectively.
CONCLUSION: The results of this survey could help in the definition of updated diagnostic reference levels (DRL). KEY POINTS: • Radiation dose associated with multidetector CT (MDCT) is an important health issue. • This national survey assessed dose exposures of 5,668 patients undergoing MDCT. • Dose indices correlate with BMI, voltage, rotation time, pitch and tube current. • These results may contribute to an update of national diagnostic reference levels.

Entities:  

Mesh:

Year:  2014        PMID: 24121713     DOI: 10.1007/s00330-013-3031-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  29 in total

1.  Diagnostic reference levels from the ACR CT Accreditation Program.

Authors:  Cynthia McCollough; Theresa Branham; Vince Herlihy; Mythreyi Bhargavan; Lavonne Robbins; Krista Bush; Michael McNitt-Gray; J Thomas Payne; Tom Ruckdeschel; Doug Pfeiffer; Dianna Cody; Robert Zeman
Journal:  J Am Coll Radiol       Date:  2011-11       Impact factor: 5.532

2.  Maltese CT doses for commonly performed examinations demonstrate alignment with published DRLs across Europe.

Authors:  Francis Zarb; Mark McEntee; Louise Rainford
Journal:  Radiat Prot Dosimetry       Date:  2011-10-12       Impact factor: 0.972

3.  Population exposure to ionising radiation from CT examinations in Aosta Valley between 2001 and 2008.

Authors:  P Catuzzo; S Aimonetto; F Zenone; G Fanelli; P Marchisio; T Meloni; M Pasquino; S Tofani
Journal:  Br J Radiol       Date:  2010-12       Impact factor: 3.039

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

5.  Establishment of CT diagnostic reference levels in Ireland.

Authors:  S J Foley; M F McEntee; L A Rainford
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

6.  Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey.

Authors:  G Brix; H D Nagel; G Stamm; R Veit; U Lechel; J Griebel; M Galanski
Journal:  Eur Radiol       Date:  2003-04-10       Impact factor: 5.315

7.  Radiation exposure from CT in early childhood: a French large-scale multicentre study.

Authors:  M-O Bernier; J-L Rehel; H J Brisse; X Wu-Zhou; S Caer-Lorho; S Jacob; J F Chateil; B Aubert; D Laurier
Journal:  Br J Radiol       Date:  2012-01       Impact factor: 3.039

8.  Radiation doses to the population of the Emilia-Romagna region from medical exposures.

Authors:  G Compagnone; P Angelini; S Domenichelli
Journal:  Radiol Med       Date:  2012-01-07       Impact factor: 3.469

Review 9.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

10.  CT radiation dose in children: a survey to establish age-based diagnostic reference levels in Switzerland.

Authors:  Francis R Verdun; Daniel Gutierrez; John Paul Vader; Abbas Aroua; Leonor Trinidad Alamo-Maestre; François Bochud; François Gudinchet
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

View more
  29 in total

1.  Computed tomography use in a large Italian region: trend analysis 2004-2014 of emergency and outpatient CT examinations in children and adults.

Authors:  Andrea Pola; Daniela Corbella; Andrea Righini; Alberto Torresin; Paola E Colombo; Luigi Vismara; Luca Trombetta; Michele Maddalo; Maria Vittoria Introini; Daniela Tinelli; Laura Strohmenger; Giovanna Garattini; Angelica Munari; Fabio Triulzi
Journal:  Eur Radiol       Date:  2018-01-09       Impact factor: 5.315

2.  Complete written/oral information about dose exposure in CT: is it really useful to guarantee the patients' awareness about radiation risks?

Authors:  Sergio Salerno; Cosimo Nardi; Chiara Tudisca; Domenica Matranga; Federica Vernuccio; Ambra Di Piazza; Valeria Selvi; Stefano Colagrande
Journal:  Radiol Med       Date:  2018-05-31       Impact factor: 3.469

3.  Survey of volume CT dose index in Japan in 2014.

Authors:  Y Matsunaga; A Kawaguchi; K Kobayashi; Y Kinomura; M Kobayashi; Y Asada; K Minami; S Suzuki; K Chida
Journal:  Br J Radiol       Date:  2015-06-04       Impact factor: 3.039

4.  Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Authors:  Peijie Lv; Zhigang Zhou; Jie Liu; Yaru Chai; Huiping Zhao; Hua Guo; Daniele Marin; Jianbo Gao
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

Review 5.  Use of radiation dose index monitoring software in a multicenter environment for CT dose optimization.

Authors:  Lucia Riccardi; Francesca De Monte; Fabiola Cretti; Silvia Pini; Sergio Zucca; Maria Grazia Quattrocchi; Daniela Origgi; Antonella Del Vecchio; Carlo Giordano; Piergiorgio Marini; Francesco Lisciandro; Edoardo Trevisiol; Daniele Zefiro; Claudia Cutaia; Loredana D'Ercole; Michele Gabusi; Alessandro Scaggion; Marta Paiusco
Journal:  Radiol Med       Date:  2018-08-09       Impact factor: 3.469

6.  CT chest abdomen pelvis doses in Scotland: has the DRL had its day?

Authors:  D G Sutton; S McVey; D Gentle; A J Hince; N MacDonald; S McCallum
Journal:  Br J Radiol       Date:  2014-06-27       Impact factor: 3.039

7.  Organ doses and lifetime attributable risk evaluations for scoliosis examinations of adolescent patients with the EOS imaging system.

Authors:  Marco Branchini; Antonella Del Vecchio; Carmen Rosaria Gigliotti; Alessandro Loria; Alberto Zerbi; Riccardo Calandrino
Journal:  Radiol Med       Date:  2017-11-21       Impact factor: 3.469

8.  Local clinical diagnostic reference levels for chest and abdomen CT examinations in adults as a function of body mass index and clinical indication: a prospective multicenter study.

Authors:  Hugues Brat; Federica Zanca; Stéphane Montandon; Damien Racine; Benoit Rizk; Eric Meicher; Dominique Fournier
Journal:  Eur Radiol       Date:  2019-05-29       Impact factor: 5.315

9.  Patient doses from CT examinations in Turkey.

Authors:  Gökçe Kaan Ataç; Aydın Parmaksız; Tolga İnal; Emine Bulur; Figen Bulgurlu; Tolga Öncü; Sadi Gündoğdu
Journal:  Diagn Interv Radiol       Date:  2015 Sep-Oct       Impact factor: 2.630

10.  Patient dose management solution directly integrated in the RIS: "Gray Detector" software.

Authors:  A Nitrosi; A Corazza; M Bertolini; R Sghedoni; P Pattacini; M Iori
Journal:  J Digit Imaging       Date:  2014-12       Impact factor: 4.056

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.