Literature DB >> 20926508

Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels.

R Treier1, A Aroua, F R Verdun, E Samara, A Stuessi, Ph R Trueb.   

Abstract

Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland.

Entities:  

Mesh:

Year:  2010        PMID: 20926508     DOI: 10.1093/rpd/ncq279

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  28 in total

1.  Establishment of CT diagnostic reference levels in Ireland.

Authors:  S J Foley; M F McEntee; L A Rainford
Journal:  Br J Radiol       Date:  2012-05-17       Impact factor: 3.039

2.  Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit.

Authors:  Denis Tack; Andreas Jahnen; Sarah Kohler; Nico Harpes; Viviane De Maertelaer; Carlo Back; Pierre Alain Gevenois
Journal:  Eur Radiol       Date:  2013-08-29       Impact factor: 5.315

3.  Survey of volume CT dose index in Japan in 2014.

Authors:  Y Matsunaga; A Kawaguchi; K Kobayashi; Y Kinomura; M Kobayashi; Y Asada; K Minami; S Suzuki; K Chida
Journal:  Br J Radiol       Date:  2015-06-04       Impact factor: 3.039

4.  Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.

Authors:  Federica Palorini; Daniela Origgi; Claudio Granata; Domenica Matranga; Sergio Salerno
Journal:  Eur Radiol       Date:  2014-02       Impact factor: 5.315

5.  An education and training programme for radiological institutes: impact on the reduction of the CT radiation dose.

Authors:  Sebastian T Schindera; Reto Treier; Gabriel von Allmen; Claude Nauer; Philipp R Trueb; Peter Vock; Zsolt Szucs-Farkas
Journal:  Eur Radiol       Date:  2011-05-31       Impact factor: 5.315

6.  Tuning of automatic exposure control strength in lumbar spine CT.

Authors:  A D'Hondt; A Cornil; P Bohy; V De Maertelaer; P A Gevenois; D Tack
Journal:  Br J Radiol       Date:  2014-03-10       Impact factor: 3.039

7.  Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?

Authors:  Peijie Lv; Zhigang Zhou; Jie Liu; Yaru Chai; Huiping Zhao; Hua Guo; Daniele Marin; Jianbo Gao
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

Review 8.  SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

Authors:  Sandra S Halliburton; Suhny Abbara; Marcus Y Chen; Ralph Gentry; Mahadevappa Mahesh; Gilbert L Raff; Leslee J Shaw; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2011 Jul-Aug

9.  Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010.

Authors:  Christoph Aberle; Nick Ryckx; Reto Treier; Sebastian Schindera
Journal:  Eur Radiol       Date:  2019-11-20       Impact factor: 5.315

10.  Establishment of national diagnostic reference levels for breast cancer CT protocols in radiation therapy.

Authors:  Sean O' Connor; Orla Mc Ardle; Laura Mullaney
Journal:  Br J Radiol       Date:  2016-07-25       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.