An end-to-end examination of geometric accuracy of IGRT using a new digital accelerator equipped with onboard imaging system.

Lei Wang1, Kayla N Kielar, Ed Mok, Annie Hsu, Sonja Dieterich, Lei Xing.   

Abstract

The Varian's new digital linear accelerator (LINAC), TrueBeam STx, is equipped with a high dose rate flattening filter free (FFF) mode (6 MV and 10 MV), a high definition multileaf collimator (2.5 mm leaf width), as well as onboard imaging capabilities. A series of end-to-end phantom tests were performed, TrueBeam-based image guided radiation therapy (IGRT), to determine the geometric accuracy of the image-guided setup and dose delivery process for all beam modalities delivered using intensity modulated radiation therapy (IMRT) and RapidArc. In these tests, an anthropomorphic phantom with a Ball Cube II insert and the analysis software (FilmQA (3cognition)) were used to evaluate the accuracy of TrueBeam image-guided setup and dose delivery. Laser cut EBT2 films with 0.15 mm accuracy were embedded into the phantom. The phantom with the film inserted was first scanned with a GE Discovery-ST CT scanner, and the images were then imported to the planning system. Plans with steep dose fall off surrounding hypothetical targets of different sizes were created using RapidArc and IMRT with FFF and WFF (with flattening filter) beams. Four RapidArc plans (6 MV and 10 MV FFF) and five IMRT plans (6 MV and 10 MV FFF; 6 MV, 10 MV and 15 MV WFF) were studied. The RapidArc plans with 6 MV FFF were planned with target diameters of 1 cm (0.52 cc), 2 cm (4.2 cc) and 3 cm (14.1 cc), and all other plans with a target diameter of 3 cm. Both onboard planar and volumetric imaging procedures were used for phantom setup and target localization. The IMRT and RapidArc plans were then delivered, and the film measurements were compared with the original treatment plans using a gamma criteria of 3%/1 mm and 3%/2 mm. The shifts required in order to align the film measured dose with the calculated dose distributions was attributed to be the targeting error. Targeting accuracy of image-guided treatment using TrueBeam was found to be within 1 mm. For irradiation of the 3 cm target, the gammas (3%, 1 mm) were found to be above 90% in all plan deliveries. For irradiations of smaller targets (2 cm and 1 cm), similar accuracy was achieved for 6 MV and 10 MV beams. Slightly degraded accuracy was observed for irradiations with higher energy beam (15 MV). In general, gammas (3%, 2 mm) were found to be above 97% for all the plans. Our end-to-end tests showed an excellent relative dosimetric agreement and sub-millimeter targeting accuracy for 6 MV and 10 MV beams, using both FFF and WFF delivery methods. However, increased deviations in spatial and dosimetric accuracy were found when treating lesions smaller than 2 cm or with 15 MV beam.

Entities:  

Mesh:

Year:  2012        PMID: 22252134      PMCID: PMC5233463          DOI: 10.1088/0031-9155/57/3/757

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm.

Authors:  Jan Hrbacek; Stephanie Lang; Stephan Klöck
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-12-02       Impact factor: 7.038

Review 2.  Overview of image-guided radiation therapy.

Authors:  Lei Xing; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Tian-Fang Li; Gwe-Ya Kim; Gary Luxton; Albert Koong
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

3.  Treatment vault shielding for a flattening filter-free medical linear accelerator.

Authors:  Stephen F Kry; Rebecca M Howell; Jerimy Polf; Radhe Mohan; Oleg N Vassiliev
Journal:  Phys Med Biol       Date:  2009-02-03       Impact factor: 3.609

4.  Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters.

Authors:  Woong Cho; Kayla N Kielar; Ed Mok; Lei Xing; Jeong-Hoon Park; Won-Gyun Jung; Tae-Suk Suh
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 5.  kV cone-beam CT-based IGRT: a clinical review.

Authors:  Judit Boda-Heggemann; Frank Lohr; Frederik Wenz; Michael Flentje; Matthias Guckenberger
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

Review 6.  Current status and future perspective of flattening filter free photon beams.

Authors:  Dietmar Georg; Tommy Knöös; Brendan McClean
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

Review 7.  The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide.

Authors:  Stine Korreman; Coen Rasch; Helen McNair; Dirk Verellen; Uwe Oelfke; Philippe Maingon; Ben Mijnheer; Vincent Khoo
Journal:  Radiother Oncol       Date:  2010-02-12       Impact factor: 6.280

8.  Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR).

Authors:  Taeho Kim; Lei Zhu; Tae-Suk Suh; Sarah Geneser; Bowen Meng; Lei Xing
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

9.  Dosimetric characteristics of 6 and 10MV unflattened photon beams.

Authors:  Gabriele Kragl; Sacha af Wetterstedt; Barbara Knäusl; Mårten Lind; Patrick McCavana; Tommy Knöös; Brendan McClean; Dietmar Georg
Journal:  Radiother Oncol       Date:  2009-07-09       Impact factor: 6.280

10.  Evaluation of GAFCHROMIC EBT film for Cyberknife dosimetry.

Authors:  Ellen E Wilcox; George M Daskalov
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

View more
  9 in total

1.  Independent calculation of monitor units for VMAT and SPORT.

Authors:  Xin Chen; Karl Bush; Aiping Ding; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

2.  Semi-automated IGRT QA using a cone-shaped scintillator screen detector for proton pencil beam scanning treatments.

Authors:  Weixing Cai; Hakan Oesten; Benjamin Clasie; Brian Winey; Kyung-Wook Jee
Journal:  Phys Med Biol       Date:  2019-04-05       Impact factor: 3.609

3.  Optimization of rotational arc station parameter optimized radiation therapy.

Authors:  P Dong; B Ungun; S Boyd; L Xing
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

4.  Verification of the machine delivery parameters of a treatment plan via deep learning.

Authors:  Jiawei Fan; Lei Xing; Ming Ma; Weigang Hu; Yong Yang
Journal:  Phys Med Biol       Date:  2020-09-30       Impact factor: 3.609

5.  Dosimetric analysis of isocentrically shielded volumetric modulated arc therapy for locally recurrent nasopharyngeal cancer.

Authors:  Jia-Yang Lu; Bao-Tian Huang; Lei Xing; Daniel T Chang; Xun Peng; Liang-Xi Xie; Zhi-Xiong Lin; Mei Li
Journal:  Sci Rep       Date:  2016-05-13       Impact factor: 4.379

6.  Commissioning and initial stereotactic ablative radiotherapy experience with Vero.

Authors:  Timothy D Solberg; Paul M Medin; Ezequiel Ramirez; Chuxiong Ding; Ryan D Foster; John Yordy
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

7.  Treatment planning system commissioning of the first clinical biology-guided radiotherapy machine.

Authors:  Eric Simiele; Dante Capaldi; Dylan Breitkreutz; Bin Han; Timothy Yeung; John White; Daniel Zaks; Michael Owens; Srinath Maganti; Lei Xing; Murat Surucu; Nataliya Kovalchuk
Journal:  J Appl Clin Med Phys       Date:  2022-05-29       Impact factor: 2.243

8.  Development and evaluation of an end-to-end test for head and neck IMRT with a novel multiple-dosimetric modality phantom.

Authors:  Viatcheslav V Zakjevskii; Cory S Knill; Joseph T Rakowski; Michael G Snyder
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

9.  The potential of an optical surface tracking system in non-coplanar single isocenter treatments of multiple brain metastases.

Authors:  Ans C C Swinnen; Michel C Öllers; Chin Loon Ong; Frank Verhaegen
Journal:  J Appl Clin Med Phys       Date:  2020-04-01       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.