Optimization of rotational arc station parameter optimized radiation therapy.

P Dong1, B Ungun1, S Boyd2, L Xing3.   

Abstract

PURPOSE: To develop a fast optimization method for station parameter optimized radiation therapy (SPORT) and show that SPORT is capable of matching VMAT in both plan quality and delivery efficiency by using three clinical cases of different disease sites.
METHODS: The angular space from 0° to 360° was divided into 180 station points (SPs). A candidate aperture was assigned to each of the SPs based on the calculation results using a column generation algorithm. The weights of the apertures were then obtained by optimizing the objective function using a state-of-the-art GPU based proximal operator graph solver. To avoid being trapped in a local minimum in beamlet-based aperture selection using the gradient descent algorithm, a stochastic gradient descent was employed here. Apertures with zero or low weight were thrown out. To find out whether there was room to further improve the plan by adding more apertures or SPs, the authors repeated the above procedure with consideration of the existing dose distribution from the last iteration. At the end of the second iteration, the weights of all the apertures were reoptimized, including those of the first iteration. The above procedure was repeated until the plan could not be improved any further. The optimization technique was assessed by using three clinical cases (prostate, head and neck, and brain) with the results compared to that obtained using conventional VMAT in terms of dosimetric properties, treatment time, and total MU.
RESULTS: Marked dosimetric quality improvement was demonstrated in the SPORT plans for all three studied cases. For the prostate case, the volume of the 50% prescription dose was decreased by 22% for the rectum and 6% for the bladder. For the head and neck case, SPORT improved the mean dose for the left and right parotids by 15% each. The maximum dose was lowered from 72.7 to 71.7 Gy for the mandible, and from 30.7 to 27.3 Gy for the spinal cord. The mean dose for the pharynx and larynx was reduced by 8% and 6%, respectively. For the brain case, the doses to the eyes, chiasm, and inner ears were all improved. SPORT shortened the treatment time by ∼1 min for the prostate case, ∼0.5 min for brain case, and ∼0.2 min for the head and neck case.
CONCLUSIONS: The dosimetric quality and delivery efficiency presented here indicate that SPORT is an intriguing alternative treatment modality. With the widespread adoption of digital linac, SPORT should lead to improved patient care in the future.

Entities:  

Mesh:

Year:  2016        PMID: 27587028      PMCID: PMC4975754          DOI: 10.1118/1.4960000

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Intensity-modulated arc therapy simplified.

Authors:  Eugene Wong; Jeff Z Chen; Jonathan Greenland
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-05-01       Impact factor: 7.038

2.  CERR: a computational environment for radiotherapy research.

Authors:  Joseph O Deasy; Angel I Blanco; Vanessa H Clark
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

3.  On the role of the optimization algorithm of RapidArc(®) volumetric modulated arc therapy on plan quality and efficiency.

Authors:  Eugenio Vanetti; Giorgia Nicolini; Janne Nord; Jarkko Peltola; Alessandro Clivio; Antonella Fogliata; Luca Cozzi
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

4.  Optimization of collimator trajectory in volumetric modulated arc therapy: development and evaluation for paraspinal SBRT.

Authors:  Pengpeng Zhang; Laura Happersett; Yingli Yang; Yoshiya Yamada; Gig Mageras; Margie Hunt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-02-19       Impact factor: 7.038

5.  An exact approach to direct aperture optimization in IMRT treatment planning.

Authors:  Chunhua Men; H Edwin Romeijn; Z Caner Taşkin; James F Dempsey
Journal:  Phys Med Biol       Date:  2007-12-05       Impact factor: 3.609

6.  Application of a new dosimetry formalism to volumetric modulated arc therapy (VMAT).

Authors:  Karen E Rosser; James L Bedford
Journal:  Phys Med Biol       Date:  2009-11-11       Impact factor: 3.609

7.  Beam’s-eye-view dosimetrics (BEVD) guided rotational station parameter optimized radiation therapy (SPORT) planning based on reweighted total-variation minimization.

Authors:  Hojin Kim; Ruijiang Li; Rena Lee; Lei Xing
Journal:  Phys Med Biol       Date:  2015-03-07       Impact factor: 3.609

8.  An adaptive planning strategy for station parameter optimized radiation therapy (SPORT): Segmentally boosted VMAT.

Authors:  Ruijiang Li; Lei Xing
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

9.  An end-to-end examination of geometric accuracy of IGRT using a new digital accelerator equipped with onboard imaging system.

Authors:  Lei Wang; Kayla N Kielar; Ed Mok; Annie Hsu; Sonja Dieterich; Lei Xing
Journal:  Phys Med Biol       Date:  2012-01-18       Impact factor: 3.609

10.  Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison.

Authors:  E Pappas; T G Maris; F Zacharopoulou; A Papadakis; S Manolopoulos; S Green; C Wojnecki
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

View more
  2 in total

1.  Use of proximal operator graph solver for radiation therapy inverse treatment planning.

Authors:  Xinmin Liu; Charles Pelizzari; Andrew H Belcher; Zachary Grelewicz; Rodney D Wiersma
Journal:  Med Phys       Date:  2017-04       Impact factor: 4.071

2.  Verification of the machine delivery parameters of a treatment plan via deep learning.

Authors:  Jiawei Fan; Lei Xing; Ming Ma; Weigang Hu; Yong Yang
Journal:  Phys Med Biol       Date:  2020-09-30       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.