Literature DB >> 21361175

Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR).

Taeho Kim1, Lei Zhu, Tae-Suk Suh, Sarah Geneser, Bowen Meng, Lei Xing.   

Abstract

PURPOSE: Radiation therapy with high dose rate and flattening filter-free (FFF) beams has the potential advantage of greatly reduced treatment time and out-of-field dose. Current inverse planning algorithms are, however, not customized for beams with nonuniform incident profiles and the resultant IMRT plans are often inefficient in delivery. The authors propose a total-variation regularization (TVR)-based formalism by taking the inherent shapes of incident beam profiles into account.
METHODS: A novel TVR-based inverse planning formalism is established for IMRT with nonuniform beam profiles. The authors introduce a TVR term into the objective function, which encourages piecewise constant fluence in the nonuniform FFF fluence domain. The proposed algorithm is applied to lung and prostate and head and neck cases and its performance is evaluated by comparing the resulting plans to those obtained using a conventional beamlet-based optimization (BBO).
RESULTS: For the prostate case, the authors' algorithm produces acceptable dose distributions with only 21 segments, while the conventional BBO requires 114 segments. For the lung case and the head and neck case, the proposed method generates similar coverage of target volume and sparing of the organs-at-risk as compared to BBO, but with a markedly reduced segment number.
CONCLUSIONS: TVR-based optimization in nonflat beam domain provides an effective way to maximally leverage the technical capacity of radiation therapy with FFF fields. The technique can generate effective IMRT plans with improved dose delivery efficiency without significant deterioration of the dose distribution.

Mesh:

Year:  2011        PMID: 21361175      PMCID: PMC3017580          DOI: 10.1118/1.3521465

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  29 in total

1.  Intensity modulated photon beams subject to a minimal surface smoothing constraint.

Authors:  M Alber; F Nüsslin
Journal:  Phys Med Biol       Date:  2000-05       Impact factor: 3.609

2.  Optimization of importance factors in inverse planning.

Authors:  L Xing; J G Li; S Donaldson; Q T Le; A L Boyer
Journal:  Phys Med Biol       Date:  1999-10       Impact factor: 3.609

3.  Smoothing intensity-modulated beam profiles to improve the efficiency of delivery.

Authors:  S V Spirou; N Fournier-Bidoz; J Yang; C S Chui; C C Ling
Journal:  Med Phys       Date:  2001-10       Impact factor: 4.071

4.  Algorithm and performance of a clinical IMRT beam-angle optimization system.

Authors:  David Djajaputra; Qiuwen Wu; Yan Wu; Radhe Mohan
Journal:  Phys Med Biol       Date:  2003-10-07       Impact factor: 3.609

5.  Segment-based dose optimization using a genetic algorithm.

Authors:  Cristian Cotrutz; Lei Xing
Journal:  Phys Med Biol       Date:  2003-09-21       Impact factor: 3.609

6.  The use of mixed-integer programming for inverse treatment planning with pre-defined field segments.

Authors:  Greg Bednarz; Darek Michalski; Chris Houser; M Saiful Huq; Ying Xiao; Pramila Rani Anne; James M Galvin
Journal:  Phys Med Biol       Date:  2002-07-07       Impact factor: 3.609

7.  Direct aperture optimization: a turnkey solution for step-and-shoot IMRT.

Authors:  D M Shepard; M A Earl; X A Li; S Naqvi; C Yu
Journal:  Med Phys       Date:  2002-06       Impact factor: 4.071

8.  Use of a quantitative index of beam modulation to characterize dose conformality: illustration by a comparison of full beamlet IMRT, few-segment IMRT (fsIMRT) and conformal unmodulated radiotherapy.

Authors:  S Webb
Journal:  Phys Med Biol       Date:  2003-07-21       Impact factor: 3.609

9.  Delivery time comparison for intensity-modulated radiation therapy with/without flattening filter: a planning study.

Authors:  Weihua Fu; Jianrong Dai; Yimin Hu; Dongsheng Han; Yixin Song
Journal:  Phys Med Biol       Date:  2004-04-21       Impact factor: 3.609

10.  Iterative methods for inverse treatment planning.

Authors:  L Xing; G T Chen
Journal:  Phys Med Biol       Date:  1996-10       Impact factor: 3.609

View more
  9 in total

1.  Bridging the gap between IMRT and VMAT: dense angularly sampled and sparse intensity modulated radiation therapy.

Authors:  Ruijiang Li; Lei Xing
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

2.  Improving IMRT delivery efficiency with reweighted L1-minimization for inverse planning.

Authors:  Hojin Kim; Stephen Becker; Rena Lee; Soonhyouk Lee; Sukyoung Shin; Emmanuel Candès; Lei Xing; Ruijiang Li
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  Dose optimization with first-order total-variation minimization for dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT).

Authors:  Hojin Kim; Ruijiang Li; Rena Lee; Thomas Goldstein; Stephen Boyd; Emmanuel Candes; Lei Xing
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

4.  Robust optimization in IMPT using quadratic objective functions to account for the minimum MU constraint.

Authors:  Jie Shan; Yu An; Martin Bues; Steven E Schild; Wei Liu
Journal:  Med Phys       Date:  2017-12-05       Impact factor: 4.071

5.  An end-to-end examination of geometric accuracy of IGRT using a new digital accelerator equipped with onboard imaging system.

Authors:  Lei Wang; Kayla N Kielar; Ed Mok; Annie Hsu; Sonja Dieterich; Lei Xing
Journal:  Phys Med Biol       Date:  2012-01-18       Impact factor: 3.609

6.  Dose compensation based on biological effectiveness due to interruption time for photon radiation therapy.

Authors:  Daisuke Kawahara; Hisashi Nakano; Akito Saito; Shuichi Ozawa; Yasushi Nagata
Journal:  Br J Radiol       Date:  2020-05-07       Impact factor: 3.039

7.  Equivalent-quality unflattened photon beam modeling, planning, and delivery.

Authors:  Yunfei Huang; Ryan T Flynn; R Alfredo C Siochi; John E Bayouth
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

8.  Efficient independent planar dose calculation for FFF IMRT QA with a bivariate Gaussian source model.

Authors:  Feifei Li; Ji-Yeon Park; Brendan Barraclough; Bo Lu; Jonathan Li; Chihray Liu; Guanghua Yan
Journal:  J Appl Clin Med Phys       Date:  2017-02-28       Impact factor: 2.102

9.  Commissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators.

Authors:  Gloria P Beyer
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.