Evaluation of GAFCHROMIC EBT film for Cyberknife dosimetry.

Ellen E Wilcox1, George M Daskalov.   

Abstract

External beam therapy (EBT) GAFCHROMIC film is evaluated for dosimetry and characterization of the CyberKnife radiation beams. Percentage depth doses, lateral beam profiles, and output factors are measured in solid water using EBT GAFCHROMIC film (International Specialty Products, Wayne, NJ) for the 6 MV radiation beams of diameter 5 to 60 mm produced by the CyberKnife (Accuray, Sunnyvale, CA). The data are compared to those measured with the PTW 60008 diode and the Wellhofer CC01 ion chamber in water. For the small radiation field sizes used in stereotactic radiosurgery, lateral electronic disequilibrium and steep dose gradients exist in a large portion of these fields, requiring the use of high-resolution measurement techniques. For small beams, the detector size approaches the dimensions of the beam and adversely affects measurement accuracy in regions where the gradient varies across the detector. When film is the detector, the scanning system is usually the resolution-limiting component. Radiographic films based upon silver halide (AgH) emulsions are widely used for relative dosimetry of external radiation treatment beams in the megavoltage energy range, because of their good spatial resolution and capability to provide integrated dosimetry over two dimensions. Film dosimetry, however, has drawbacks due to its steep energy dependence at low photon energies as well as film processor and densitometer artifacts. EBT radiochromic film, introduced in 2004 specifically for IMRT dosimetry, may be a detector of choice for the characterization of small radiosurgical beams, because of its near-tissue equivalence, radiation beam energy independence, high spatial resolution, and self developing properties. For radiation beam sizes greater than 10 mm, the film measurements were identical to those of the diode and ion chamber. For the smaller beam diameters of 7.5 and 5 mm, however, there were differences in the data measured with the different detectors, which are attributed to their different spatial resolution and non-water-equivalence.

Entities:  

Mesh:

Year:  2007        PMID: 17654899     DOI: 10.1118/1.2734384

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  18FDG-PET/CT Definition of Clinical Target Volume for Robotic Stereotactic Body Radiosurgery Treatment of Metastatic Gynecologic Malignancies.

Authors:  Charles A Kunos; Robert Debernardo; Jeffrey Fabien; Donald C Dobbins; Yuxia Zhang; James Brindle; Peter F Faulhaber
Journal:  J Nucl Med Radiat Ther       Date:  2011-12-12

3.  An end-to-end examination of geometric accuracy of IGRT using a new digital accelerator equipped with onboard imaging system.

Authors:  Lei Wang; Kayla N Kielar; Ed Mok; Annie Hsu; Sonja Dieterich; Lei Xing
Journal:  Phys Med Biol       Date:  2012-01-18       Impact factor: 3.609

4.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

5.  Comparative analysis between 5 mm and 7.5 mm collimators in CyberKnife radiosurgery for trigeminal neuralgia.

Authors:  H Sudahar; P G G Kurup; V Murali; J Velmurugan
Journal:  J Med Phys       Date:  2013-07

6.  Stereotactic radiosurgery for gynecologic cancer.

Authors:  Charles Kunos; James M Brindle; Robert Debernardo
Journal:  J Vis Exp       Date:  2012-04-17       Impact factor: 1.355

7.  Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers.

Authors:  S Xu; C Xie; Z Ju; X Dai; H Gong; L Wang; J Yang
Journal:  Biomed Imaging Interv J       Date:  2010-04-01

8.  Use of new radiochromic devices for peripheral dose measurement: potential in-vivo dosimetry application.

Authors:  S-T Chiu-Tsao; Mf Chan
Journal:  Biomed Imaging Interv J       Date:  2009-10-01

9.  Synthesis and Characterization of a New Nanocomposite Film Based on Polyvinyl Alcohol Polymer and Nitro Blue Tetrazolium Dye as a Low Radiation Dosimeter in Medical Diagnostics Application.

Authors:  Saleh Alashrah; Yassine El-Ghoul; Mohammed Ahmed Ali Omer
Journal:  Polymers (Basel)       Date:  2021-05-31       Impact factor: 4.329

10.  Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies.

Authors:  Charles A Kunos; James Brindle; Steven Waggoner; Kristine Zanotti; Kimberly Resnick; Nancy Fusco; Ramon Adams; Robert Debernardo
Journal:  Front Oncol       Date:  2012-12-05       Impact factor: 6.244

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.