PURPOSE: Determination of the cup orientation after metal-on-metal hip resurfacing may provide important information in the postoperative follow-up. We present a mathematical method based on a previously described approach to assess the version and inclination of the cup in the metal-on-metal bearing without a separate software computation from plain radiographs. The aim of the study was to assess the intra- and inter-observer reliability of this method. METHODS: Calculation of version and inclination were done twice for 20 hip resurfacings by four observers. Intra-observer reliability was estimated by mean error and correlation of the two sets of measurement for version and inclination. Bland-Altman plots, intra-class coefficient and mean error were used to assess the inter-observer reliability of the measurements. RESULTS: Intra-observer correlation for version measurement ranged from 0.74 to 0.94. Correlation for inclination varied between 0.94 and 0.97. Upper and lower limits of agreement in Bland-Altman plots for version measurements between observers ranged from 4.1 to 7.2 degrees and from -3.2 to -8.3 degrees, respectively. For inclination measurements the upper and lower limits ranged from 3.1 to 5.3 degrees and from -2.7 to -6.0 degrees. CONCLUSIONS: Mean errors, correlation coefficients and 95% limits of agreement were on an acceptable level. We believe that this method is applicable for clinical use.
PURPOSE: Determination of the cup orientation after metal-on-metal hip resurfacing may provide important information in the postoperative follow-up. We present a mathematical method based on a previously described approach to assess the version and inclination of the cup in the metal-on-metal bearing without a separate software computation from plain radiographs. The aim of the study was to assess the intra- and inter-observer reliability of this method. METHODS: Calculation of version and inclination were done twice for 20 hip resurfacings by four observers. Intra-observer reliability was estimated by mean error and correlation of the two sets of measurement for version and inclination. Bland-Altman plots, intra-class coefficient and mean error were used to assess the inter-observer reliability of the measurements. RESULTS: Intra-observer correlation for version measurement ranged from 0.74 to 0.94. Correlation for inclination varied between 0.94 and 0.97. Upper and lower limits of agreement in Bland-Altman plots for version measurements between observers ranged from 4.1 to 7.2 degrees and from -3.2 to -8.3 degrees, respectively. For inclination measurements the upper and lower limits ranged from 3.1 to 5.3 degrees and from -2.7 to -6.0 degrees. CONCLUSIONS: Mean errors, correlation coefficients and 95% limits of agreement were on an acceptable level. We believe that this method is applicable for clinical use.
Authors: Henrik Olivecrona; Lars Weidenhielm; Lotta Olivecrona; Mats O Beckman; André Stark; Marilyn E Noz; Gerald Q Maguire; Michael P Zeleznik; Lars Svensson; Torbjörn Jonson Journal: Acta Orthop Scand Date: 2004-06