Literature DB >> 7083664

Analysis of version in the acetabular cup.

H Seradge, K R Nagle, R J Miller.   

Abstract

To determine the amount of anteversion or retroversion of the acetabular component of the implanted total hip prosthesis, two anteroposterior radiographs of the hip are obtained, with the contralateral hip flexed to compensate for the possible existing flexion contracture. The X-ray beam is centered on the implanted total hip in one radiograph, and moved away from it toward the contralateral hip in the second radiograph. If the cup is anteverted, the opening will seem wider in the second radiograph. To calculate the angle, the location of the center of the X-ray beam on the X-ray plate must be know. The center of the X-ray beam can be marked on the radiograph by putting a metalic cross on the patient, over the centering cross of the X-ray light source. If the distance of the signature of the X-ray's center beam is less than 8 mm for the center of the cup on the X-ray film, the cup version can be calculated from the arcsin of the shortest to the largest diameter of the cup. If the central ray's signature is farther away, correction is necessary for this calculation. Also, the variable parameters, e.g., cup size, and magnification rate, should be considered in the calculations. The anteroposterior radiographs of the implanted total hip, obtained with the central beam being marked on the X-ray plate, not only are useful for evaluation of the implant but also can be used to calculate the version angle with an accuracy of +/-2 degrees. The necessary calculation is tabulated for cups with an outside diameter of 44-56 mm.

Entities:  

Mesh:

Year:  1982        PMID: 7083664

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  12 in total

1.  Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

Authors:  J-Y Lazennec; N Charlot; M Gorin; B Roger; N Arafati; A Bissery; G Saillant
Journal:  Surg Radiol Anat       Date:  2003-11-07       Impact factor: 1.246

2.  Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing.

Authors:  Aleksi Reito; Timo Puolakka; Antti Paakkala; Jorma Pajamäki
Journal:  Int Orthop       Date:  2011-08-12       Impact factor: 3.075

3.  A cadaver study validating CT assessment of acetabular component orientation: the Perth CT hip protocol.

Authors:  Varun Arora; Richard Hannan; Richard Beaver; Timothy Fletcher; Paul Harvie
Journal:  Skeletal Radiol       Date:  2016-11-08       Impact factor: 2.199

4.  Acetabular cup-siting device for total hip arthroplasty.

Authors:  J Doyle; P Murray; P O Mahony; M Farmer; A C Hooper
Journal:  Arch Orthop Trauma Surg       Date:  1989       Impact factor: 3.067

5.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

Review 6.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

7.  How Reliable is the Acetabular Cup Position Assessment from Routine Radiographs?

Authors:  Jaime A Carvajal Alba; Heather K Vincent; Jagdeep S Sodhi; Loren L Latta; Hari K Parvataneni
Journal:  Iowa Orthop J       Date:  2017

8.  The synergetic effect of pelvic rotation and X-ray offset on radiographic angles of the acetabular cup.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Guo-Fei Sun; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Med Biol Eng Comput       Date:  2019-09-09       Impact factor: 2.602

9.  Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA.

Authors:  G Zheng; J von Recum; L-P Nolte; P A Grützner; S D Steppacher; J Franke
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-27       Impact factor: 2.924

10.  CT outperforms radiography for determination of acetabular cup version after THA.

Authors:  Bernard Ghelman; Christopher K Kepler; Stephen Lyman; Alejandro González Della Valle
Journal:  Clin Orthop Relat Res       Date:  2009-03-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.