Literature DB >> 11462858

Variations of pelvic anteversion in the lying and standing positions: analysis of 24 control subjects and implications for CT measurement of position of a prosthetic cup.

T A Eddine1, H Migaud, C Chantelot, A Cotten, C Fontaine, A Duquennoy.   

Abstract

The position of the acetabular implant plays a dominant role in the displacement of a total hip prosthesis. CT allows precise measurement of the position of the cup, but the influence of pelvic rotation on this measurement is unknown. The aim of this study was to determine, in a group of healthy subjects, whether a pelvic equilibrium exists specific to each individual, and whether this is constant over time on the one hand and between the standing and lying positions on the other. The study concerned 15 men and 9 women with a mean age of 31 years. Each subject had strictly lateral radiographs of the pelvis, lying and standing, repeated at two different times. Pelvic version was measured in these radiographs. Each individual had a pelvic position constant over time, both in the lying and standing positions. However, there were important variations of the position of the pelvis during passage from the lying to the standing position: 22 patients had retroversion of the pelvis by a mean of 7 degrees (2-18 degrees) and 2 others had an anteversion of 3 degrees. These major variations of the pelvic position between the standing and lying positions explain why CT studies made in the lying position do not allow for the anteversion of the cup in the standing position, which is close to the dynamic situation during which displacement may occur. Thus, an excessive anteversion of the cup may be masked when the scan is made in the lying position, since in this position the anteversion of the pelvis leads to retroversion of the cup. The error may reach 20 degrees, so that we recommend that CT measurements made without allowing for the position of the pelvis should be interpreted with caution.

Entities:  

Mesh:

Year:  2001        PMID: 11462858     DOI: 10.1007/s00276-001-0105-z

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  32 in total

1.  Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning.

Authors:  J-Y Lazennec; N Charlot; M Gorin; B Roger; N Arafati; A Bissery; G Saillant
Journal:  Surg Radiol Anat       Date:  2003-11-07       Impact factor: 1.246

2.  Variations of caudal, central, and cranial acetabular anteversion according to the tilt of the pelvis.

Authors:  S Zilber; J Y Lazennec; M Gorin; G Saillant
Journal:  Surg Radiol Anat       Date:  2004-12       Impact factor: 1.246

3.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

4.  Assessment of cup position from plain radiographs: impact of pelvic tilting.

Authors:  M Haenle; A Heitner; W Mittelmeier; R Barbano; R Scholz; E Steinhauser; R Bader
Journal:  Surg Radiol Anat       Date:  2007-01-10       Impact factor: 1.246

Review 5.  Computer assisted orthopaedic surgery -- CAOS.

Authors:  Enes M Kanlić; Fabian Delarosa; Miguel Pirela-Cruz
Journal:  Bosn J Basic Med Sci       Date:  2006-02       Impact factor: 3.363

6.  Validation of a simple radiographic method to determine variations in pelvic and acetabular cup sagittal plane alignment after total hip arthroplasty.

Authors:  Won Yong Shon; Siddhartha Gupta; Sandeep Biswal; Chang Yong Hur; Nirmal Jajodia; Suk Joo Hong; Jae Sung Myung
Journal:  Skeletal Radiol       Date:  2008-08-07       Impact factor: 2.199

7.  Toward a dynamic approach of THA planning based on ultrasound.

Authors:  Guillaume Dardenne; Stéphane Dusseau; Chafiaâ Hamitouche; Christian Lefèvre; Eric Stindel
Journal:  Clin Orthop Relat Res       Date:  2008-08-08       Impact factor: 4.176

8.  Influence of the sagittal balance of the spine on the anterior pelvic plane and on the acetabular orientation.

Authors:  Jean Legaye
Journal:  Int Orthop       Date:  2009-01-16       Impact factor: 3.075

Review 9.  Imaging and navigation measurement of acetabular component position in THA.

Authors:  Zhinian Wan; Aamer Malik; Branislav Jaramaz; Lisa Chao; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

10.  Estimation of pelvic tilt on anteroposterior X-rays--a comparison of six parameters.

Authors:  M Tannast; S B Murphy; F Langlotz; S E Anderson; K A Siebenrock
Journal:  Skeletal Radiol       Date:  2005-12-20       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.