Do survival rate and serum ion concentrations 10 years after metal-on-metal hip resurfacing provide evidence for continued use?

Albrecht Hartmann1, Jörg Lützner, Stephan Kirschner, Wolf-Christoph Witzleb, Klaus-Peter Günther.   

Abstract

BACKGROUND: Owing to concerns attributable to problems associated with metal-on-metal bearing surfaces, current evidence for the use of hip resurfacing is unclear. Survival rates reported from registries and individual studies are controversial and the limited long-term studies do not conclusively allow one to judge whether hip resurfacing is still a reasonable alternative to conventional THA. QUESTIONS/PURPOSES: We asked whether the long-term survival rate of hip resurfacing is comparable to that of conventional THA and certain factors can be identified that influence serum ion concentration 10 years postoperatively. We specifically assessed (1) the 10-year survivorship in the whole cohort and in male and female patients, (2) serum concentrations of metal ions in patients with hip resurfacing who had not undergone revision surgery, and (3) potential influencing factors on the serum ion concentration.
METHODS: We retrospectively reviewed our first 95 patients who had 100 hip resurfacings performed from 1998 to 2001. The median age of the patients at surgery was 52 years (range, 28-69 years); 49% were men. We assessed the survival rate (revision for any reason as the end point), radiographic changes, and serum ion concentrations for cobalt, chromium, and molybdenum. The correlations between serum ion concentration and patient-related factors (age, sex, BMI, activity) and implant-related factors (implant size, cup inclination, stem-shaft angle) were investigated. The minimum followup was 9.3 years (mean, 10 years; range, 9.3-10.5 years).
RESULTS: The 10-year survivorship was 88% for the total cohort. The overall survival rate was greater in men (93%) than in women (84%). Median serum ion levels were 1.9 μg/L for chromium, 1.3 μg/L for cobalt, and 1.6 μg/L for molybdenum. Radiolucent lines around acetabular implants were observed in 4% and femoral neck thinning in 5%.
CONCLUSIONS: Although our overall failure rate was greater than anticipated, the relatively low serum ion levels and no revisions for pseudotumors in young male patients up to 10 years postoperatively provide some evidence of the suitability of hip resurfacing in this subgroup. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22481276      PMCID: PMC3462856          DOI: 10.1007/s11999-012-2329-0

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  47 in total

1.  "Asymptomatic" pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study.

Authors:  Young-Min Kwon; Simon J Ostlere; Peter McLardy-Smith; Nicholas A Athanasou; Harinderjit S Gill; David W Murray
Journal:  J Arthroplasty       Date:  2010-06-29       Impact factor: 4.757

2.  Birmingham Hip Resurfacing arthroplasty: short-term clinical and radiographic outcome.

Authors:  Wolf-Christoph Witzleb; M Arnold; F Krummenauer; A Knecht; H Ranisch; K-P Günther
Journal:  Eur J Med Res       Date:  2008-01-23       Impact factor: 2.175

Review 3.  Cementless femoral components in young patients: review and meta-analysis of total hip arthroplasty and hip resurfacing.

Authors:  Bryan D Springer; Sarah E Connelly; Susan M Odum; Thomas K Fehring; William L Griffin; J Bohannon Mason; John L Masonis
Journal:  J Arthroplasty       Date:  2009-06-24       Impact factor: 4.757

4.  Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.

Authors:  D J Langton; T J Joyce; S S Jameson; J Lord; M Van Orsouw; J P Holland; A V F Nargol; K A De Smet
Journal:  J Bone Joint Surg Br       Date:  2011-02

5.  Comparison of patient-reported outcomes between hip resurfacing and total hip replacement.

Authors:  E A Lingard; K Muthumayandi; J P Holland
Journal:  J Bone Joint Surg Br       Date:  2009-12

6.  Pseudotumours associated with metal-on-metal hip resurfacings.

Authors:  H Pandit; S Glyn-Jones; P McLardy-Smith; R Gundle; D Whitwell; C L M Gibbons; S Ostlere; N Athanasou; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-07

7.  Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study.

Authors:  Harlan C Amstutz; Paul E Beaulé; Frederick J Dorey; Michel J Le Duff; Pat A Campbell; Thomas A Gruen
Journal:  J Bone Joint Surg Am       Date:  2004-01       Impact factor: 5.284

8.  Determination of chromium, cobalt and molybdenum in synovial fluid by GFAAS.

Authors:  S J Lugowski; D C Smith; A D McHugh; J C Van Loon
Journal:  J Trace Elem Electrolytes Health Dis       Date:  1991-03

Review 9.  Metal-on-metal hip resurfacing arthroplasty.

Authors:  Andrew Shimmin; Paul E Beaulé; Pat Campbell
Journal:  J Bone Joint Surg Am       Date:  2008-03       Impact factor: 5.284

Review 10.  The clinical and radiological outcomes of hip resurfacing versus total hip arthroplasty: a meta-analysis and systematic review.

Authors:  Toby O Smith; Rachel Nichols; Simon T Donell; Caroline B Hing
Journal:  Acta Orthop       Date:  2010-11-11       Impact factor: 3.717

View more
  11 in total

1.  [Complications of metal-on-metal tribological pairing].

Authors:  M Stiehler; F Zobel; F Hannemann; J Schmitt; J Lützner; S Kirschner; K-P Günther; A Hartmann
Journal:  Orthopade       Date:  2014-01       Impact factor: 1.087

2.  Comparison of metal ion levels in patients with hip resurfacing versus total hip arthroplasty.

Authors:  Craig W Forsthoefel; Nicholas M Brown; Mark L Barba
Journal:  J Orthop       Date:  2017-08-31

3.  The First SICOT Oral Presentation Award 2011: imageless computer-assisted femoral component positioning in hip resurfacing: a prospective randomised trial.

Authors:  Maik Stiehler; Jens Goronzy; Albrecht Hartmann; Frank Krummenauer; Klaus-Peter Günther
Journal:  Int Orthop       Date:  2013-02-06       Impact factor: 3.075

4.  Brain structure and function in patients after metal-on-metal hip resurfacing.

Authors:  M J Clark; J R Prentice; N Hoggard; M N Paley; M Hadjivassiliou; J M Wilkinson
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-10       Impact factor: 3.825

5.  [Update on metal-on-metal hip joints].

Authors:  K-P Günther; J Lützner; F Hannemann; J Schmitt; S Kirschner; J Goronzy; M Stiehler; C Lohmann; A Hartmann
Journal:  Orthopade       Date:  2013-05       Impact factor: 1.087

6.  Do ion levels in metal-on-metal hip resurfacing differ from those in metal-on-metal THA at long-term followup?

Authors:  Lucia Savarino; Matteo Cadossi; Eugenio Chiarello; Nicola Baldini; Sandro Giannini
Journal:  Clin Orthop Relat Res       Date:  2013-04-10       Impact factor: 4.176

7.  Current indications for hip resurfacing arthroplasty in 2016.

Authors:  Robert Sershon; Rishi Balkissoon; Craig J Della Valle
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

8.  Effect of surgical experience on imageless computer-assisted femoral component positioning in hip resurfacing--a preclinical study.

Authors:  Maik Stiehler; Jens Goronzy; Stephan Kirschner; Albrecht Hartmann; Torsten Schäfer; Klaus-Peter Günther
Journal:  Eur J Med Res       Date:  2015-02-24       Impact factor: 2.175

9.  Metal-on-metal hip prostheses and systemic health: a cross-sectional association study 8 years after implantation.

Authors:  Jennifer R Prentice; Matthew J Clark; Nigel Hoggard; Allison C Morton; Claire Tooth; Martyn N Paley; Ian Stockley; Marios Hadjivassiliou; J Mark Wilkinson
Journal:  PLoS One       Date:  2013-06-10       Impact factor: 3.240

10.  Auditory and visual health after ten years of exposure to metal-on-metal hip prostheses: a cross-sectional study follow up.

Authors:  Jennifer R Prentice; Christopher S Blackwell; Naz Raoof; Paul Bacon; Jaydip Ray; Simon J Hickman; J Mark Wilkinson
Journal:  PLoS One       Date:  2014-03-12       Impact factor: 3.240