A method to measure acetabular cup anteversion after total hip replacement.

L Fabeck1, D Farrokh, M Tolley, P Y Descamps, M Gebhart, P Delincé.   

Abstract

The authors propose a simple and practical method to measure radiologically the angle of ante- or retroversion of the acetabular cup using a goniometer. It only necessitates an anteroposterior radiograph centered on the femoral head and another one centered on the public symphysis. Special x ray equipment, compass, conversion table, mathematical formulas, or a pocket calculator are not required. The opening of the prosthetic cup is projected on the film as an ellipse. According to the rules of descriptive geometry, the true size of the angle of anteversion is easily obtained. The geometric constructions consist in drawing four lines. The adequate positioning on a hip radiograph of the protractor, drawn on the goniometer, permits the direct reading of the true and planar anteversion angles of the cup.

Entities:  

Mesh:

Year:  1999        PMID: 10675944

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  10 in total

1.  A new method of measuring acetabular cup anteversion on simulated radiographs.

Authors:  Vikas Bachhal; Nipun Jindal; Gaurav Saini; Radheshyam Sament; Vishal Kumar; Devendra Chouhan; Mandeep Dhillon
Journal:  Int Orthop       Date:  2012-05-31       Impact factor: 3.075

2.  Estimation of pelvic tilt on anteroposterior X-rays--a comparison of six parameters.

Authors:  M Tannast; S B Murphy; F Langlotz; S E Anderson; K A Siebenrock
Journal:  Skeletal Radiol       Date:  2005-12-20       Impact factor: 2.199

3.  Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing.

Authors:  Aleksi Reito; Timo Puolakka; Antti Paakkala; Jorma Pajamäki
Journal:  Int Orthop       Date:  2011-08-12       Impact factor: 3.075

Review 4.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

5.  SuperPath® vs. direct anterior approach : A retrospective comparison between two minimally invasive approaches in total hip arthroplasty.

Authors:  André Busch; Alexander Wegner; Dennis Wassenaar; Daniel Brandenburger; Marcel Haversath; Marcus Jäger
Journal:  Orthopadie (Heidelb)       Date:  2022-10-07

6.  GeoGebra: A reliable and free software for measuring acetabular cup anteversion on digitalized plain radiographs.

Authors:  Vikas Bachhal; Gaurav Saini; Nipun Jindal; Radheshyam Sament; Ankit Dadra
Journal:  J Clin Orthop Trauma       Date:  2020-02-05

7.  Poor accuracy of freehand cup positioning during total hip arthroplasty.

Authors:  B H Bosker; C C P M Verheyen; W G Horstmann; N J A Tulp
Journal:  Arch Orthop Trauma Surg       Date:  2007-02-13       Impact factor: 3.067

8.  Acetabular cup orientation and postoperative leg length discrepancy in patients undergoing elective total hip arthroplasty via a direct anterior and anterolateral approaches.

Authors:  Ronen Debi; Evyatar Slamowicz; Ornit Cohen; Avi Elbaz; Omri Lubovsky; Dror Lakstein; Zachary Tan; Ehud Atoun
Journal:  BMC Musculoskelet Disord       Date:  2018-06-08       Impact factor: 2.362

9.  THR Simulator--the software for generating radiographs of THR prosthesis.

Authors:  Tai-Yin Wu; Rong-Sen Yang; Chiou-Shann Fuh; Sheng-Mou Hou; Chen-Kun Liaw
Journal:  BMC Musculoskelet Disord       Date:  2009-01-16       Impact factor: 2.362

10.  Pelvic incidence: a predictive factor for three-dimensional acetabular orientation-a preliminary study.

Authors:  Christophe Boulay; Gérard Bollini; Jean Legaye; Christine Tardieu; Dominique Prat-Pradal; Brigitte Chabrol; Jean-Luc Jouve; Ginette Duval-Beaupère; Jacques Pélissier
Journal:  Anat Res Int       Date:  2014-03-18