Literature DB >> 15067657

A simplified method to determine acetabular cup anteversion from plain radiographs.

Karl-Heinz Widmer1.   

Abstract

Plain radiographs are the most important diagnostic means for determining the indication and following up on total hip arthroplasty. The acetabular cup position can be easily determined by applying trigonometric functions. This report presents an even simpler method. The short axis of the projected ellipse is measured and related to the total cross-section of the projected cup along the short axis. This relationship correlates with acetabular cup anteversion angles and represents an inverse sinus function. A close linear correlation is seen within the most common interval from 10 degrees to 30 degrees. Anteversion is between 23 degrees to 24 degrees when the ellipse bisects the total acetabular cross-section. This means that simply measuring the length of the short ellipse axis and the total length of the projected cross-section along the short axis provides the radiographic acetabular anteversion. Nonorthogonal projected radiographs should be corrected first.

Entities:  

Mesh:

Year:  2004        PMID: 15067657     DOI: 10.1016/j.arth.2003.10.016

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  90 in total

1.  A new method of measuring acetabular cup anteversion on simulated radiographs.

Authors:  Vikas Bachhal; Nipun Jindal; Gaurav Saini; Radheshyam Sament; Vishal Kumar; Devendra Chouhan; Mandeep Dhillon
Journal:  Int Orthop       Date:  2012-05-31       Impact factor: 3.075

2.  Reply to comments on: Assessment of inter- and intra-observer reliability in the determination of radiographic version and inclination of the cup in metal-on-metal hip resurfacing.

Authors:  Aleksi Reito; Timo Puolakka; Antti Paakkala; Jorma Pajamäki
Journal:  Int Orthop       Date:  2012-07-11       Impact factor: 3.075

3.  Accuracy and reliability of different methods to evaluate the acetabular cup version from plain radiographs.

Authors:  Maximilian Haenle; Wolfram Mittelmeier; Rodrigo Barbano; Klaus Wörtler; Roger Scholz; Rainer Bader
Journal:  Surg Radiol Anat       Date:  2010-06-25       Impact factor: 1.246

4.  Acetabular component positioning using anatomic landmarks of the acetabulum.

Authors:  Yong-Chan Ha; Jeong Joon Yoo; Young-Kyun Lee; Jin Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

5.  Does warming up improve surgical outcome in total hip arthroplasty?

Authors:  Asim M Makhdom; AbdulAziz Almaawi; Dylan Tanzer; Michael Tanzer
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-08-20

6.  Assessment of cup position from plain radiographs: impact of pelvic tilting.

Authors:  M Haenle; A Heitner; W Mittelmeier; R Barbano; R Scholz; E Steinhauser; R Bader
Journal:  Surg Radiol Anat       Date:  2007-01-10       Impact factor: 1.246

7.  Acetabular augmentation ring for recurrent dislocation of total hip arthroplasty: 60% stability rate after an average follow-up of 74 months.

Authors:  B H Bosker; H B Ettema; C C P M Verheyen; R M Castelein
Journal:  Int Orthop       Date:  2007-10-19       Impact factor: 3.075

Review 8.  Enhanced acetabular component positioning through computer-assisted navigation.

Authors:  Thomas Ybinger; Wolfgang Kumpan
Journal:  Int Orthop       Date:  2007-08       Impact factor: 3.075

9.  A novel non-invasive mechanical technique of cup and stem placement and leg length adjustment in total hip arthroplasty for dysplastic hips.

Authors:  Takashi Murayama; Hideo Ohnishi; Toshiharu Mori; Yuichi Okazaki; Kenji Sujita; Akinori Sakai
Journal:  Int Orthop       Date:  2014-12-09       Impact factor: 3.075

10.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.