The noise power spectrum in CT with direct fan beam reconstruction.

Jongduk Baek1, Norbert J Pelc.   

Abstract

The noise power spectrum (NPS) is a useful metric for understanding the noise content in images. To examine some unique properties of the NPS of fan beam CT, the authors derived an analytical expression for the NPS of fan beam CT and validated it with computer simulations. The nonstationary noise behavior of fan beam CT was examined by analyzing local regions and the entire field-of-view (FOV). This was performed for cases with uniform as well as nonuniform noise across the detector cells and across views. The simulated NPS from the entire FOV and local regions showed good agreement with the analytically derived NPS. The analysis shows that whereas the NPS of a large FOV in parallel beam CT (using a ramp filter) is proportional to frequency, the NPS with direct fan beam FBP reconstruction shows a high frequency roll off. Even in small regions, the fan beam NPS can show a sharp transition (discontinuity) at high frequencies. These effects are due to the variable magnification and therefore are more pronounced as the fan angle increases. For cases with nonuniform noise, the NPS can show the directional dependence and additional effects.

Entities:  

Mesh:

Year:  2010        PMID: 20527540      PMCID: PMC2871306          DOI: 10.1118/1.3378673

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  An experimental comparison of detector performance for computed radiography systems.

Authors:  Ehsan Samei; Michael J Flynn
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

2.  Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography.

Authors:  Xiaochuan Pan; Lifeng Yu
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

3.  An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.

Authors:  Jing Wang; Hongbing Lu; Tianfang Li; Zhengrong Liang
Journal:  Med Phys       Date:  2005-11       Impact factor: 4.071

4.  Experimental optical fan beam tomography.

Authors:  K E Bennett; G W Faris; R L Byer
Journal:  Appl Opt       Date:  1984-08-15       Impact factor: 1.980

5.  Estimation of the local statistical noise in emission computed tomography.

Authors:  N M Alpert; D A Chesler; J A Correia; R H Ackerman; J Y Chang; S Finklestein; S M Davis; G L Brownell; J M Taveras
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

6.  Optical tomography: experimental verification of noise theory.

Authors:  K Bennett; R L Byer
Journal:  Opt Lett       Date:  1984-07-01       Impact factor: 3.776

7.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

8.  Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function.

Authors:  K Faulkner; B M Moores
Journal:  Phys Med Biol       Date:  1984-11       Impact factor: 3.609

9.  The noise power spectrum in computed X-ray tomography.

Authors:  S J Riederer; N J Pelc; D A Chesler
Journal:  Phys Med Biol       Date:  1978-05       Impact factor: 3.609

10.  Detectability in computed tomographic images.

Authors:  K M Hanson
Journal:  Med Phys       Date:  1979 Sep-Oct       Impact factor: 4.071

View more
  22 in total

1.  Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

Authors:  F Gay; Y Pavia; N Pierrat; S Lasalle; S Neuenschwander; H J Brisse
Journal:  Eur Radiol       Date:  2013-08-31       Impact factor: 5.315

2.  Investigation of Noise and Contrast Sensitivity of an Electron Multiplying Charge-Coupled Device (EMCCD) based Cone Beam Micro-CT System.

Authors:  Sumukh Bysani Krishnakumar; Alexander R Podgorsak; Sv Setlur Nagesh; Amit Jain; Stephen Rudin; Daniel R Bednarek; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-25

3.  Preconditioned alternating projection algorithm for solving the penalized-likelihood SPECT reconstruction problem.

Authors:  Si Li; Jiahan Zhang; Andrzej Krol; C Ross Schmidtlein; David Feiglin; Yuesheng Xu
Journal:  Phys Med       Date:  2017-05-09       Impact factor: 2.685

4.  Local and global 3D noise power spectrum in cone-beam CT system with FDK reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

5.  Effect of detector lag on CT noise power spectra.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

6.  Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Joseph Goerres; Matthew W Jacobson; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2017-07-11       Impact factor: 10.048

7.  Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.071

8.  Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: theoretical framework using a cascaded system model and experimental validation.

Authors:  Ke Li; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction.

Authors:  Wei-Hua Yin; Bin Lu; Zhi-Hui Hou; Nan Li; Lei Han; Yong-Jian Wu; Hong-Xia Niu; Justin R Silverman; Carlo Nicola De Cecco; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2013-06-27       Impact factor: 5.315

10.  A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array.

Authors:  Jongduk Baek; Bruno De Man; Jorge Uribe; Randy Longtin; Daniel Harrison; Joseph Reynolds; Bogdan Neculaes; Kristopher Frutschy; Louis Inzinna; Antonio Caiafa; Robert Senzig; Norbert J Pelc
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.