Literature DB >> 28708549

Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy.

Michael D Ketcha, Tharindu De Silva, Runze Han, Ali Uneri, Joseph Goerres, Matthew W Jacobson, Sebastian Vogt, Gerhard Kleinszig, Jeffrey H Siewerdsen.   

Abstract

For image-guided procedures, the imaging task is often tied to the registration of intraoperative and preoperative images to a common coordinate system. While the accuracy of this registration is a vital factor in system performance, there is a relatively little work that relates registration accuracy to image quality factors, such as dose, noise, and spatial resolution. To create a theoretical model for such a relationship, we present a Fisher information approach to analyze registration performance in explicit dependence on the underlying image quality factors of image noise, spatial resolution, and signal power spectrum. The model yields analysis of the Cramer-Rao lower bound (CRLB), in registration accuracy as a function of factors governing image quality. Experiments were performed in simulation of computed tomography low-contrast soft tissue images and high-contrast bone (head and neck) images to compare the measured accuracy [root mean squared error (RMSE) of the estimated transformations] with the theoretical lower bound. Analysis of the CRLB reveals that registration performance is closely related to the signal-to-noise ratio of the cross-correlation space. While the lower bound is optimistic, it exhibits consistent trends with experimental findings and yields a method for comparing the performance of various registration methods and similarity metrics. Further analysis validated a method for determining optimal post-processing (image filtering) for registration. Two figures of merit (CRLB and RMSE) are presented that unify models of image quality with registration performance, providing an important guide to optimizing intraoperative imaging with respect to the task of registration.

Entities:  

Mesh:

Year:  2017        PMID: 28708549      PMCID: PMC5696623          DOI: 10.1109/TMI.2017.2725644

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  24 in total

1.  Estimation of the noisy component of anatomical backgrounds.

Authors:  F O Bochud; J F Valley; F R Verdun; C Hessler; P Schnyder
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

2.  Fundamental performance limits in image registration.

Authors:  Dirk Robinson; Peyman Milanfar
Journal:  IEEE Trans Image Process       Date:  2004-09       Impact factor: 10.856

3.  Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.

Authors:  Angel R Pineda; Daniel J Tward; Antonio Gonzalez; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

4.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

5.  Fundamental limits of image registration performance: Effects of image noise and resolution in CT-guided interventions.

Authors:  M D Ketcha; T de Silva; R Han; A Uneri; J Goerres; M Jacobson; S Vogt; G Kleinszig; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-03

6.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

7.  Evaluation of low-dose limits in 3D-2D rigid registration for surgical guidance.

Authors:  A Uneri; A S Wang; Y Otake; G Kleinszig; S Vogt; A J Khanna; G L Gallia; Z L Gokaslan; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

8.  Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization.

Authors:  J Xu; A Sisniega; W Zbijewski; H Dang; J W Stayman; X Wang; D H Foos; N Aygun; V E Koliatsos; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-30       Impact factor: 3.609

9.  Task-driven optimization of CT tube current modulation and regularization in model-based iterative reconstruction.

Authors:  Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Phys Med Biol       Date:  2017-03-31       Impact factor: 3.609

10.  Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

Authors:  Grace J Gang; Junghoon Lee; J Webster Stayman; Daniel J Tward; W Zbijewski; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

View more
  3 in total

1.  A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2019-03-27       Impact factor: 10.048

2.  Learning-based deformable image registration: effect of statistical mismatch between train and test images.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  J Med Imaging (Bellingham)       Date:  2019-12-17

3.  ESTIMATING DIFFEOMORPHIC MAPPINGS BETWEEN TEMPLATES AND NOISY DATA: VARIANCE BOUNDS ON THE ESTIMATED CANONICAL VOLUME FORM.

Authors:  Daniel J Tward; Partha P Mitra; Michael I Miller
Journal:  Q Appl Math       Date:  2018-11-20       Impact factor: 0.815

  3 in total