Literature DB >> 16372414

An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.

Jing Wang1, Hongbing Lu, Tianfang Li, Zhengrong Liang.   

Abstract

It has been observed that the variances in reconstructed images from stationary noisy projection data by fan-beam filtered backprojection (fFBP) algorithm with ramp in the filtering step and linear interpolation in the backprojection step are nonuniform across the field-of-view. This is believed to be caused by the distance-dependent 1/L2 factor in the fFBP reconstruction formula. Shift-variant filtration approach in the filtering step has been investigated to address the nonuniform noise propagation problem in fFBP. In this work, we present an alternative solution by the use of spatially variant weighting, instead of spatially invariant interpolation, in the backprojection step, while maintaining the homogeneous ramp filtering. Both theoretically predicted and empirically determined results concur and demonstrate the effectiveness of the presented alternative solution.

Entities:  

Mesh:

Year:  2005        PMID: 16372414      PMCID: PMC1379631          DOI: 10.1118/1.2064807

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Optimal noise control in and fast reconstruction of fan-beam computed tomography image.

Authors:  X Pan
Journal:  Med Phys       Date:  1999-05       Impact factor: 4.071

2.  Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography.

Authors:  Xiaochuan Pan; Lifeng Yu
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

3.  Nonuniform noise propagation by using the ramp filter in fan-beam computed tomography.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Med Imaging       Date:  2004-06       Impact factor: 10.048

4.  Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts.

Authors:  J Hsieh
Journal:  Med Phys       Date:  1997-09       Impact factor: 4.071

  4 in total
  7 in total

1.  Backprojection-filtration reconstruction without invoking a spatially varying weighting factor.

Authors:  Dan Xia; Seungryong Cho; Xiaochuan Pan
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Authors:  Adam Wunderlich; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

3.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

4.  Filtered Backprojection Reconstruction with Depth-Dependent Filtering.

Authors:  Frank Dennerlein; Holger Kunze; Frédéric Noo
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

5.  Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  Phys Med Biol       Date:  2008-04-18       Impact factor: 3.609

6.  Virtual Colonoscopy Screening with Ultra Low-Dose CT and Less-Stressful Bowel Preparation: A computer simulation study.

Authors:  Jing Wang; Su Wang; Lihong Li; Yi Fan; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2008-10       Impact factor: 1.679

7.  FDK-Type Algorithms with No Backprojection Weight for Circular and Helical Scan CT.

Authors:  A V Narasimhadhan; Kasi Rajgopal
Journal:  Int J Biomed Imaging       Date:  2012-02-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.