Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT.

Pascal Theriault Lauzier1, Guang-Hong Chen.   

Abstract

PURPOSE: Prior image constrained compressed sensing (PICCS) is an image reconstruction framework that takes advantage of a prior image to improve the image quality of CT reconstructions. An interesting question that remains to be investigated is whether or not the introduction of a statistical model of the photon detection in the PICCS reconstruction framework can improve the performance of the algorithm when dealing with high noise projection datasets. The goal of the research presented in this paper is to characterize the noise properties of images reconstructed using PICCS with and without statistical modeling. This paper investigates these properties in the clinical context of time-resolved contrast-enhanced CT.
METHODS: Both numerical phantom studies and an Institutional Review Board approved human subject study were used in this research. The conventional filtered backprojection (FBP), and PICCS with and without the statistical model were applied to each dataset. The prior image used in PICCS was generated by averaging over FBP reconstructions from different time frames of the time-resolved CT exam, thus reducing the noise level. Numerical studies were used to evaluate if the noise characteristics are altered for varying levels of noise, as well as for different object shapes. The dataset acquired in vivo was used to verify that the conclusions reached from numerical studies translate adequately to a clinical case. The results were analyzed using a variety of qualitative and quantitative metrics such as the universal image quality index, spatial maps of the noise standard deviations, the noise uniformity, the noise power spectrum, and the model-observer detectability.
RESULTS: The noise characteristics of PICCS were shown to depend on the noise level contained in the data, the level of eccentricity of the object, and whether or not the statistical model was applied. Most differences in the characteristics were observed in the regime of low incident x-ray fluence. No substantial difference was observed between PICCS with and without statistics in the high fluence domain. Objects with a semi-major axis ratio below 0.85 were more accurately reconstructed with lower noise using the statistical implementation. Above that range, for mostly circular objects, the PICCS implementation without the statistical model yielded more accurate images and a lower noise level. At all levels of eccentricity, the noise spatial distribution was more uniform and the model-observer detectability was greater for PICCS with the statistical model. The human subject study was consistent with the results obtained using numerical simulations.
CONCLUSIONS: For mildly eccentric objects in the low noise regime, PICCS without the noise model yielded equal or better noise level and image quality than the statistical formulation. However, in a vast majority of cases, images reconstructed using statistical PICCS have a noise power spectrum that facilitated the detection of model lesions. The inclusion of a statistical model in the PICCS framework does not always result in improved noise characteristics.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23039632      PMCID: PMC3461052          DOI: 10.1118/1.4748323

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  51 in total

1.  Visual signal detection in structured backgrounds. III. Calculation of figures of merit for model observers in statistically nonstationary backgrounds.

Authors:  F O Bochud; C K Abbey; M P Eckstein
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2000-02       Impact factor: 2.129

2.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies.

Authors:  Jie Tang; Jiang Hsieh; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

4.  Renal perfusion and hemodynamics: accurate in vivo determination at CT with a 10-fold decrease in radiation dose and HYPR noise reduction.

Authors:  Xin Liu; Andrew N Primak; James D Krier; Lifeng Yu; Lilach O Lerman; Cynthia H McCollough
Journal:  Radiology       Date:  2009-10       Impact factor: 11.105

5.  Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction.

Authors:  Mark Supanich; Yinghua Tao; Brian Nett; Kari Pulfer; Jiang Hsieh; Patrick Turski; Charles Mistretta; Howard Rowley; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2009-06-30       Impact factor: 3.609

6.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

7.  A splitting-based iterative algorithm for accelerated statistical X-ray CT reconstruction.

Authors:  Sathish Ramani; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2011-11-08       Impact factor: 10.048

8.  Dynamic perfusion CT: optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients.

Authors:  Andreas Kämena; Florian Streitparth; Christian Grieser; Lukas Lehmkuhl; Basil Jamil; Katarzyna Wojtal; Jens Ricke; Maciej Pech
Journal:  Eur J Radiol       Date:  2007-03-23       Impact factor: 3.528

9.  Effect of noise correlation on detectability of disk signals in medical imaging.

Authors:  K J Myers; H H Barrett; M C Borgstrom; D D Patton; G W Seeley
Journal:  J Opt Soc Am A       Date:  1985-10       Impact factor: 2.129

10.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

View more
  9 in total

1.  Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

Authors:  Pascal Theriault Lauzier; Guang-Hong Chen
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

2.  Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance.

Authors:  Ke Li; John Garrett; Yongshuai Ge; Guang-Hong Chen
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

Review 3.  Regularization strategies in statistical image reconstruction of low-dose x-ray CT: A review.

Authors:  Hao Zhang; Jing Wang; Dong Zeng; Xi Tao; Jianhua Ma
Journal:  Med Phys       Date:  2018-09-10       Impact factor: 4.071

4.  Mixed Confidence Estimation for Iterative CT Reconstruction.

Authors:  David S Perlmutter; Soo Mee Kim; Paul E Kinahan; Adam M Alessio
Journal:  IEEE Trans Med Imaging       Date:  2016-03-17       Impact factor: 10.048

5.  Noise Suppression for Dual-Energy CT Through Entropy Minimization.

Authors:  Michael Petrongolo; Lei Zhu
Journal:  IEEE Trans Med Imaging       Date:  2015-05-01       Impact factor: 10.048

6.  PIRPLE: a penalized-likelihood framework for incorporation of prior images in CT reconstruction.

Authors:  J Webster Stayman; Hao Dang; Yifu Ding; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-10-10       Impact factor: 3.609

7.  Accelerated barrier optimization compressed sensing (ABOCS) for CT reconstruction with improved convergence.

Authors:  Tianye Niu; Xiaojing Ye; Quentin Fruhauf; Michael Petrongolo; Lei Zhu
Journal:  Phys Med Biol       Date:  2014-03-14       Impact factor: 3.609

8.  Statistical image reconstruction for low-dose CT using nonlocal means-based regularization.

Authors:  Hao Zhang; Jianhua Ma; Jing Wang; Yan Liu; Hongbing Lu; Zhengrong Liang
Journal:  Comput Med Imaging Graph       Date:  2014-05-14       Impact factor: 4.790

9.  Iterative image reconstruction for sparse-view CT using normal-dose image induced total variation prior.

Authors:  Jing Huang; Yunwan Zhang; Jianhua Ma; Dong Zeng; Zhaoying Bian; Shanzhou Niu; Qianjin Feng; Zhengrong Liang; Wufan Chen
Journal:  PLoS One       Date:  2013-11-18       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.