Estimation of the local statistical noise in emission computed tomography.

N M Alpert, D A Chesler, J A Correia, R H Ackerman, J Y Chang, S Finklestein, S M Davis, G L Brownell, J M Taveras.   

Abstract

A simple modification of the filtered backprojection algorithm is presented for the computation of the local statistical noise in emission computed tomography. The technique is general in that any distribution of radioactivity may be accommodated. When applied to positron emission tomography, it is shown that the effects of photon absorption, random coincidences, radioactive decay, and detector nonuniformity may be included. Calculations have shown the effects of resolution, object size, and photon absorption on the statistical noise of disk-shaped emitters. Comparison of calculation and experiment show close agreement both in magnitude and spatial variation. Measurements of the noise level in tomograms of the brain obtained during continuous inhalation of 150-CO2 demonstrate that estimates of radioactivity concentration with a precision of a few percent are readily attainable.

Entities:  

Year:  1982        PMID: 18238267     DOI: 10.1109/TMI.1982.4307561

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  12 in total

1.  Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Authors:  Adam Wunderlich; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

2.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  Evaluation of basis function and linear least squares methods for generating parametric blood flow images using 15O-water and Positron Emission Tomography.

Authors:  Ronald Boellaard; Paul Knaapen; Abraham Rijbroek; Gert J J Luurtsema; Adriaan A Lammertsma
Journal:  Mol Imaging Biol       Date:  2005 Jul-Aug       Impact factor: 3.488

4.  Local and global 3D noise power spectrum in cone-beam CT system with FDK reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

Review 5.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

Review 6.  Precision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: A technical perspective.

Authors:  Jonathan B Moody; Benjamin C Lee; James R Corbett; Edward P Ficaro; Venkatesh L Murthy
Journal:  J Nucl Cardiol       Date:  2015-04-14       Impact factor: 5.952

7.  Selection of weighting factors for quantification of PET radioligand binding using simplified reference tissue models with noisy input functions.

Authors:  M D Normandin; R A Koeppe; E D Morris
Journal:  Phys Med Biol       Date:  2012-01-12       Impact factor: 3.609

8.  Spatial Auto-Regressive Analysis of Correlation in 3-D PET With Application to Model-Based Simulation of Data.

Authors:  Jian Huang; Tian Mou; Kevin O'Regan; Finbarr O'Sullivan
Journal:  IEEE Trans Med Imaging       Date:  2019-08-29       Impact factor: 10.048

9.  Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration.

Authors:  Uttam M Shrestha; Youngho Seo; Elias H Botvinick; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2015-10-09       Impact factor: 3.609

10.  Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM.

Authors:  Pasha Razifar; Mattias Sandström; Harald Schnieder; Bengt Långström; Enn Maripuu; Ewert Bengtsson; Mats Bergström
Journal:  BMC Med Imaging       Date:  2005-08-25       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.