Literature DB >> 6505016

Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function.

K Faulkner, B M Moores.   

Abstract

A discrete representation of the reconstruction process, consistent with the method of data collection, has been used to derive expressions for the noise power spectrum, autocorrelation function and noise equivalent quanta (NEQ) of a computed tomography (CT) image. These parameters have been expressed in terms of basic scanning factors such as tube current, exposure time, slice width and number of detectors. Each of these factors affects the overall magnitude of the noise power spectrum, but the spatial frequency dependence is also determined by the type of reconstruction filter used in the computer algorithm. The noise power spectrum has been calculated for scanners employing either a ramp or Hanning weighted ramp filter. Predictions made from this theoretical analysis have been compared with experimental measurements made on various CT scanners. Measurements were made of the modulation transfer function (MTF) by techniques which permitted us to deduce the contributions of the algorithmic and non-algorithmic components to the overall MTF. NEQ values have been calculated for a number of CT scanners.

Mesh:

Year:  1984        PMID: 6505016     DOI: 10.1088/0031-9155/29/11/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Noise simulation in cone beam CT imaging with parallel computing.

Authors:  Shu-Ju Tu; Chris C Shaw; Lingyun Chen
Journal:  Phys Med Biol       Date:  2006-02-15       Impact factor: 3.609

3.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  Three-dimensional linear system analysis for breast tomosynthesis.

Authors:  Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

5.  Local and global 3D noise power spectrum in cone-beam CT system with FDK reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

6.  Characterization of imaging performance in differential phase contrast CT compared with the conventional CT--noise power spectrum NPS(k).

Authors:  Xiangyang Tang; Yi Yang; Shaojie Tang
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

7.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

8.  Image Noise Covariance Can be Adjusted by a Noise Weighted Filtered Backprojection Algorithm.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-02-18

9.  Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: spectrum of noise equivalent quanta NEQ(k).

Authors:  Xiangyang Tang; Yi Yang; Shaojie Tang
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

10.  Non-isotropic noise correlation in PET data reconstructed by FBP but not by OSEM demonstrated using auto-correlation function.

Authors:  Pasha Razifar; Mark Lubberink; Harald Schneider; Bengt Långström; Ewert Bengtsson; Mats Bergström
Journal:  BMC Med Imaging       Date:  2005-05-13       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.