Literature DB >> 23807568

Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction.

Wei-Hua Yin1, Bin Lu, Zhi-Hui Hou, Nan Li, Lei Han, Yong-Jian Wu, Hong-Xia Niu, Justin R Silverman, Carlo Nicola De Cecco, U Joseph Schoepf.   

Abstract

OBJECTIVES: To evaluate the diagnostic accuracy of sub-milliSievert (mSv) coronary CT angiography (cCTA) using prospectively ECG-triggered high-pitch spiral CT acquisition combined with iterative image reconstruction.
METHODS: Forty consecutive patients (52.9 ± 8.7 years; 30 men) underwent dual-source cCTA using prospectively ECG-triggered high-pitch spiral acquisition. The tube current-time product was set to 50 % of standard-of-care CT examinations. Images were reconstructed with sinogram-affirmed iterative reconstruction. Image quality was scored and diagnostic performance for detection of ≥50 % stenosis was determined with catheter coronary angiography (CCA) as the reference standard.
RESULTS: CT was successfully performed in all 40 patients. Of the 601 assessable coronary segments, 543 (90.3 %) had diagnostic image quality. Per-patient sensitivity for detection of ≥50 % stenosis was 95.7 % [95 % confidence interval (CI), 76.0-99.8 %] and specificity was 94.1 % (95 % CI, 69.2-99.7 %). Per-vessel sensitivity was 89.5 % (95 % CI, 77.8-95.6 %) with 93.2 % specificity (95 % CI, 86.0-97.0 %). The area under the receiver-operating characteristic curve on per-patient and per-vessel levels was 0.949 and 0.913. Mean effective dose was 0.58 ± 0.17 mSv. Mean size-specific dose estimate was 3.14 ± 1.15 mGy.
CONCLUSIONS: High-pitch prospectively ECG-triggered cCTA combined with iterative image reconstruction provides high diagnostic accuracy with a radiation dose below 1 mSv for detection of coronary artery stenosis. KEY POINTS: • Cardiac CT with sub-milliSievert radiation dose is feasible in many patients • High-pitch spiral CT acquisition with iterative reconstruction detects coronary stenosis accurately. • Iterative reconstruction increases who can benefit from low-radiation cardiac CT.

Entities:  

Mesh:

Year:  2013        PMID: 23807568     DOI: 10.1007/s00330-013-2920-0

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  16 in total

1.  CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction.

Authors:  Ullrich Ebersberger; Francesco Tricarico; U Joseph Schoepf; Philipp Blanke; J Reid Spears; Garrett W Rowe; William T Halligan; Thomas Henzler; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2012-07-10       Impact factor: 5.315

2.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

3.  ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance.

Authors:  Allen J Taylor; Manuel Cerqueira; John McB Hodgson; Daniel Mark; James Min; Patrick O'Gara; Geoffrey D Rubin; Christopher M Kramer; Daniel Berman; Alan Brown; Farooq A Chaudhry; Ricardo C Cury; Milind Y Desai; Andrew J Einstein; Antoinette S Gomes; Robert Harrington; Udo Hoffmann; Rahul Khare; John Lesser; Christopher McGann; Alan Rosenberg; Robert Schwartz; Marc Shelton; Gerald W Smetana; Sidney C Smith
Journal:  J Am Coll Cardiol       Date:  2010-11-23       Impact factor: 24.094

4.  Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography.

Authors:  Stephan Achenbach; Tobias Goroll; Martin Seltmann; Tobias Pflederer; Katharina Anders; Dieter Ropers; Werner G Daniel; Michael Uder; Michael Lell; Mohamed Marwan
Journal:  JACC Cardiovasc Imaging       Date:  2011-04

5.  Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients.

Authors:  Ming-Li Sun; Bin Lu; Run-Ze Wu; Laura Johnson; Lei Han; Gang Liu; Fang-Fang Yu; Zhi-Hui Hou; Yang Gao; Hong-Yu Wang; Shiliang Jiang; Yue-Jin Yang; Shu-Bin Qiao
Journal:  Eur Radiol       Date:  2011-04-12       Impact factor: 5.315

6.  Iterative image reconstruction techniques: Applications for cardiac CT.

Authors:  Matthias Renker; Ashok Ramachandra; U Joseph Schoepf; Rainer Raupach; Paul Apfaltrer; Garrett W Rowe; Sebastian Vogt; Thomas G Flohr; J Matthias Kerl; Ralf W Bauer; Christian Fink; Thomas Henzler
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-05-25

7.  Cardiovascular CT angiography in neonates and children: image quality and potential for radiation dose reduction with iterative image reconstruction techniques.

Authors:  Francesco Tricarico; Anthony M Hlavacek; U Joseph Schoepf; Ullrich Ebersberger; John W Nance; Rozemarijn Vliegenthart; Young Jun Cho; J Reid Spears; Francesco Secchi; Giancarlo Savino; Riccardo Marano; Stefan O Schoenberg; Lorenzo Bonomo; Paul Apfaltrer
Journal:  Eur Radiol       Date:  2012-12-04       Impact factor: 5.315

8.  Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose <0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction.

Authors:  Annika Schuhbaeck; Stephan Achenbach; Christian Layritz; Jasmin Eisentopf; Franziska Hecker; Tobias Pflederer; Soeren Gauss; Johannes Rixe; Willi Kalender; Werner G Daniel; Michael Lell; Dieter Ropers
Journal:  Eur Radiol       Date:  2012-09-16       Impact factor: 5.315

9.  Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential.

Authors:  Anna Winklehner; Christoph Karlo; Gilbert Puippe; Bernhard Schmidt; Thomas Flohr; Robert Goetti; Thomas Pfammatter; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2011-08-06       Impact factor: 5.315

10.  Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction.

Authors:  Matthias Renker; John W Nance; U Joseph Schoepf; Terrence X O'Brien; Peter L Zwerner; Mathias Meyer; J Matthias Kerl; Ralf W Bauer; Christian Fink; Thomas J Vogl; Thomas Henzler
Journal:  Radiology       Date:  2011-06-21       Impact factor: 11.105

View more
  18 in total

1.  Radiation dose of coronary CT angiography with a third-generation dual-source CT in a "real-world" patient population.

Authors:  Aleksander Kosmala; Bernhard Petritsch; Andreas Max Weng; Thorsten Alexander Bley; Tobias Gassenmaier
Journal:  Eur Radiol       Date:  2018-11-30       Impact factor: 5.315

2.  Dose levels and image quality of second-generation 128-slice dual-source coronary CT angiography in clinical routine.

Authors:  Julian L Wichmann; Xiaohan Hu; Alexander Engler; J Matthias Kerl; Martin Beeres; Claudia Frellesen; Wolfgang Luboldt; Thomas J Vogl; Ralf W Bauer; Thomas Lehnert
Journal:  Radiol Med       Date:  2015-05-16       Impact factor: 3.469

3.  Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography.

Authors:  Sonja Gordic; Lotus Desbiolles; Martin Sedlmair; Robert Manka; André Plass; Bernhard Schmidt; Daniela B Husarik; Francesco Maisano; Simon Wildermuth; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2015-06-03       Impact factor: 5.315

Review 4.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

5.  High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate.

Authors:  Sonja Gordic; Daniela B Husarik; Lotus Desbiolles; Sebastian Leschka; Thomas Frauenfelder; Hatem Alkadhi
Journal:  Int J Cardiovasc Imaging       Date:  2014-05-11       Impact factor: 2.357

6.  Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.

Authors:  Long Jiang Zhang; Li Qi; Jing Wang; Chun Xiang Tang; Chang Sheng Zhou; Xue Man Ji; James V Spearman; Carlo Nicola De Cecco; Felix G Meinel; U Joseph Schoepf; Guang Ming Lu
Journal:  Eur Radiol       Date:  2014-04-16       Impact factor: 5.315

Review 7.  The role of advanced reconstruction algorithms in cardiac CT.

Authors:  Sandra S Halliburton; Yuki Tanabe; Sasan Partovi; Prabhakar Rajiah
Journal:  Cardiovasc Diagn Ther       Date:  2017-10

8.  Image quality and diagnostic accuracy of coronary CT angiography derived from low-dose dynamic CT myocardial perfusion: a feasibility study with comparison to invasive coronary angiography.

Authors:  Xu Dai; Mengmeng Yu; Jingwei Pan; Zhigang Lu; Chengxing Shen; Yining Wang; Bin Lu; Jiayin Zhang
Journal:  Eur Radiol       Date:  2018-11-09       Impact factor: 5.315

Review 9.  Pregnancy-Associated Myocardial Infarction.

Authors:  Michael C Honigberg; Nandita S Scott
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-06-19

10.  Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols.

Authors:  D Beitzke; V Berger-Kulemann; V Schöpf; S Unterhumer; E Spitzer; G M Feuchtner; M Gyöngyösi; K Uyanik-Uenal; A Zuckermann; C Loewe; F Wolf
Journal:  Eur Radiol       Date:  2015-04-26       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.