The noise power spectrum in computed X-ray tomography.

S J Riederer, N J Pelc, D A Chesler.   

Abstract

An expression is derived showing that the two-dimensional noise power spectrum of computed X-ray tomography is proportional to [G(k)]2/k where k is the radial spatial frequency and G(k) is the one-dimensional corrective filter used in the filtered back-projection reconstuction technique. It is shown that predicted noise power spectra compare well with those estimated from CT reconstructions of simulated noise for both the ramp filter and the Hanning-weighted ramp filter. A consequence of the non-uniform shape of the noise power spectrum is that statistical noise in CT reconstructions is correlated from point to point. Because of this correlation when the reconstructed CT values are averaged over some region, the uncertainty of the average depends on the shape of the region as well as its area. This dependence is confirmed by computer simulations.

Mesh:

Year:  1978        PMID: 674361     DOI: 10.1088/0031-9155/23/3/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  41 in total

1.  Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.

Authors:  Angel R Pineda; Daniel J Tward; Antonio Gonzalez; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Authors:  Adam Wunderlich; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

3.  Dose and detectability for a cone-beam C-arm CT system revisited.

Authors:  Arundhuti Ganguly; Sungwon Yoon; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

4.  The noise power spectrum in CT with direct fan beam reconstruction.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

Review 5.  Collimator design for single photon emission tomography.

Authors:  S C Moore; K Kouris; I Cullum
Journal:  Eur J Nucl Med       Date:  1992

6.  Noise simulation in cone beam CT imaging with parallel computing.

Authors:  Shu-Ju Tu; Chris C Shaw; Lingyun Chen
Journal:  Phys Med Biol       Date:  2006-02-15       Impact factor: 3.609

7.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

8.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Three-dimensional linear system analysis for breast tomosynthesis.

Authors:  Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

10.  Noise power properties of a cone-beam CT system for breast cancer detection.

Authors:  Kai Yang; Alexander L C Kwan; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.