Literature DB >> 20360343

Feasibility of angiographic CT in peri-interventional diagnostic imaging: a comparative study with multidetector CT.

M-N Psychogios1, J-H Buhk, P Schramm, A Xyda, A Mohr, M Knauth.   

Abstract

BACKGROUND AND
PURPOSE: The ability to perform neuroimaging on the angiography suite is important in making decisions during neurointerventions. Our aim was the evaluation of ACT as a fast available diagnostic tool during and after neuroendovascular procedures and the comparison of ACT with postinterventional MDCT.
MATERIALS AND METHODS: Eighty-four peri-interventional ACT acquisitions were obtained and evaluated: 38 after coil embolization of cerebral aneurysms, 16 after intracranial angioplasty with stent placement, and 30 after endovascular mechanical thrombectomy and lysis. Interventions and ACTs were performed on a biplane angiography system equipped with flat panel detectors. Postprocessing was performed on a dedicated workstation, and multiplanar reformations were generated. Reference studies were performed on a 16- or 128-section MDCT scanner. All studies were independently evaluated by 3 blinded neuroradiologists. The Wilcoxon test was applied for the statistical analysis.
RESULTS: ACT and MDCT images were of equal diagnostic quality in most cases related to the supratentorial ventricular system and the detection of hemorrhages (subarachnoidal, intraparenchymal, and intraventricular). Regarding the supratentorial ventricular system, an adequate diagnostic quality was assigned to 94% of the ACT acquisitions. For the detection of hemorrhage, no statistically significant difference was noted between ACT and MDCT. However, for the infratentorial region, ACT performed relatively poorly compared with MDCT. The diagnostic evaluation of gray matter (basal ganglia, insular cortex, and central cortex) by ACT is not sufficient, with <20% of the acquisitions scoring a diagnostic value.
CONCLUSIONS: After neuroendovascular procedures and within the angiography suite, ACT enables an immediate detection of peri-interventional hemorrhage or hydrocephalus. However, for the detection of cerebral infarction, ACT is not yet reliable.

Entities:  

Mesh:

Year:  2010        PMID: 20360343      PMCID: PMC7965444          DOI: 10.3174/ajnr.A2086

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  15 in total

1.  A performance comparison of flat-panel imager-based MV and kV cone-beam CT.

Authors:  B A Groh; J H Siewerdsen; D G Drake; J W Wong; D A Jaffray
Journal:  Med Phys       Date:  2002-06       Impact factor: 4.071

2.  [The use of flat-panel detectors for CT imaging].

Authors:  W A Kalender
Journal:  Radiologe       Date:  2003-05       Impact factor: 0.635

3.  Angiographic CT in cerebrovascular stenting.

Authors:  Götz Benndorf; Charles M Strother; Benjamin Claus; Ramin Naeini; Hesham Morsi; Richard Klucznik; Michael E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

Review 4.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

5.  Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.

Authors:  N Ebrahimi; B Claus; C-Y Lee; A Biondi; G Benndorf
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

6.  Visualisation of intracerebral haemorrhage with flat-detector CT compared to multislice CT: results in 44 cases.

Authors:  Tobias Struffert; Gregor Richter; Tobias Engelhorn; Marc Doelken; Philipp Goelitz; Willi A Kalender; Oliver Ganslandt; Arnd Doerfler
Journal:  Eur Radiol       Date:  2008-09-24       Impact factor: 5.315

7.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.

Authors:  M J Daly; J H Siewerdsen; D J Moseley; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

8.  Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms--a comparative study with DSA and TOF-MRA.

Authors:  Jan-Hendrik Buhk; Kai Kallenberg; Alexander Mohr; Peter Dechent; Michael Knauth
Journal:  Eur Radiol       Date:  2008-09-23       Impact factor: 5.315

9.  Neuroradiologic applications with routine C-arm flat panel detector CT: evaluation of patient dose measurements.

Authors:  Y Kyriakou; G Richter; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-07       Impact factor: 3.825

10.  Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting.

Authors:  Jan-Hendrik Buhk; Paul Lingor; Michael Knauth
Journal:  Neuroradiology       Date:  2008-02-02       Impact factor: 2.804

View more
  21 in total

1.  Angiographic CT for intraprocedural monitoring of complex neuroendovascular procedures.

Authors:  J Pfaff; T Struffert; P Gölitz; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-05       Impact factor: 3.825

2.  Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

Authors:  M-N Psychogios; P Schramm; J-H Buhk; A Xyda; K Gröschel; K Jung; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

3.  Flat panel angiography images in the post-operative follow-up of surgically clipped intracranial aneurysms.

Authors:  Caterina Budai; Luigi Cirillo; Francesco Patruno; Massimo Dall'olio; Ciro Princiotta; Marco Leonardi
Journal:  Neuroradiol J       Date:  2014-04-18

4.  Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis.

Authors:  J S Jeon; S H Sheen; G J Hwang; H C Kim; B J Kwon
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-30       Impact factor: 3.825

5.  Impact of a new metal artefact reduction algorithm in the noninvasive follow-up of intracranial clips, coils, and stents with flat-panel angiographic CTA: initial results.

Authors:  Marios-Nikos Psychogios; Bernhard Scholz; Christopher Rohkohl; Yiannis Kyriakou; Alexander Mohr; Peter Schramm; Dorothee Wachter; Katrin Wasser; Michael Knauth
Journal:  Neuroradiology       Date:  2013-04-16       Impact factor: 2.804

6.  Intraparenchymal Hyperattenuations on Flat-Panel CT Directly After Mechanical Thrombectomy are Restricted to the Initial Infarct Core on Diffusion-Weighted Imaging.

Authors:  Tanja Schneider; Tobias Mahraun; Julian Schroeder; Andreas Frölich; Philip Hoelter; Marlies Wagner; Jean Darcourt; Christophe Cognard; Alain Bonafé; Jens Fiehler; Susanne Siemonsen; Jan-Hendrik Buhk
Journal:  Clin Neuroradiol       Date:  2016-09-16       Impact factor: 3.649

7.  Feasibility of cerebral blood volume mapping by flat panel detector CT in the angiography suite: first experience in patients with acute middle cerebral artery occlusions.

Authors:  T Struffert; Y Deuerling-Zheng; T Engelhorn; S Kloska; P Gölitz; M Köhrmann; S Schwab; C M Strother; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-29       Impact factor: 3.825

8.  Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment.

Authors:  Yukiko Enomoto; Keita Yamauchi; Takahiko Asano; Katharina Otani; Toru Iwama
Journal:  Interv Neuroradiol       Date:  2018-02-21       Impact factor: 1.610

9.  Intravenous flat-detector CT angiography in acute ischemic stroke management.

Authors:  Raphaël Blanc; Silvia Pistocchi; Drazenko Babic; Bruno Bartolini; Michaël Obadia; Sonia Alamowitch; Michel Piotin
Journal:  Neuroradiology       Date:  2011-05-31       Impact factor: 2.804

10.  Use of cone-beam computed tomography angiography in planning for gamma knife radiosurgery for arteriovenous malformations: a case series and early report.

Authors:  Mina G Safain; Jason P Rahal; Ami Raval; Mark J Rivard; John E Mignano; Julian K Wu; Adel M Malek
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

View more