Literature DB >> 20634309

Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

M-N Psychogios1, P Schramm, J-H Buhk, A Xyda, K Gröschel, K Jung, M Knauth.   

Abstract

BACKGROUND AND
PURPOSE: ICAS is one of the therapeutic options in symptomatic cerebral artery stenosis. iaDSA is the current criterion standard examination after ICAS for the detection of ISR. In this study, we evaluated ivACT as a potential noninvasive follow-up alternative.
MATERIALS AND METHODS: In 17 cases, ivACT and iaDSA were performed after ICAS. Both procedures were carried out on a flat-panel-detector-equipped angiography system. Postprocessing of ivACT acquisitions was performed on a dedicated workstation producing multiplanar reformations of the stent region and other intracranial arteries. Restenotic lesions were compared with iaDSA measurements. All studies were independently evaluated by 2 experienced neuroradiologists blinded to patients data.
RESULTS: In 5 cases, ISR was diagnosed on iaDSA images. All restenotic lesions were reliably detected (sensitivity, 100%; 95%CI, 48%-100%) and could be correctly quantified on ivACT images in comparison with iaDSA. The neuroradiologists correctly excluded ISR in 11 of 12 lesions after viewing the ivACT examinations (specificity, 92%; 95%CI, 62%-100%). Measurements of ISR on ivACT were highly correlated to iaDSA (Pearson r = 0.94, P < .01).
CONCLUSIONS: IvACT is a promising noninvasive follow-up examination after ICAS. With its high spatial resolution, it can reliably detect or exclude ISR. Contrary to iaDSA, there is no need for a recovery period after ivACT and the risk of neurologic complications is practically lowered to zero.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20634309      PMCID: PMC7964033          DOI: 10.3174/ajnr.A2168

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  31 in total

1.  How accurate is CT angiography in evaluating intracranial atherosclerotic disease?

Authors:  Mai N Nguyen-Huynh; Max Wintermark; Joey English; Jack Lam; Eric Vittinghoff; Wade S Smith; S Claiborne Johnston
Journal:  Stroke       Date:  2008-02-21       Impact factor: 7.914

2.  Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.

Authors:  N Ebrahimi; B Claus; C-Y Lee; A Biondi; G Benndorf
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

Review 3.  [Basic principles of flat detector computed tomography (FD-CT)].

Authors:  Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

4.  Re: Turk et al and the "how do we spin wingspan?" commentary.

Authors:  C P Derdeyn; M I Chimowitz
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-03       Impact factor: 3.825

5.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

6.  Influence of patient age and stenosis location on wingspan in-stent restenosis.

Authors:  A S Turk; E I Levy; F C Albuquerque; G L Pride; H Woo; B G Welch; D B Niemann; P D Purdy; B Aagaard-Kienitz; P A Rasmussen; L N Hopkins; T J Masaryk; C G McDougall; D Fiorella
Journal:  AJNR Am J Neuroradiol       Date:  2007-11-07       Impact factor: 3.825

7.  The safety of dedicated-team catheter-based diagnostic cerebral angiography in the era of advanced noninvasive imaging.

Authors:  R Thiex; A M Norbash; K U Frerichs
Journal:  AJNR Am J Neuroradiol       Date:  2009-09-24       Impact factor: 3.825

Review 8.  Neurologic complications of cerebral angiography: prospective analysis of 2,899 procedures and review of the literature.

Authors:  Robert A Willinsky; Steve M Taylor; Karel TerBrugge; Richard I Farb; George Tomlinson; Walter Montanera
Journal:  Radiology       Date:  2003-03-13       Impact factor: 11.105

9.  Stent-assisted reconstructive endovascular repair of cranial fusiform atherosclerotic and dissecting aneurysms: long-term clinical and angiographic follow-up.

Authors:  Ajay K Wakhloo; Jake Mandell; Matthew J Gounis; Christopher Brooks; Italo Linfante; Jesse Winer; John P Weaver
Journal:  Stroke       Date:  2008-09-04       Impact factor: 7.914

10.  An original flow diversion device for the treatment of intracranial aneurysms: evaluation in the rabbit elastase-induced model.

Authors:  Chander Sadasivan; Liliana Cesar; Jaehoon Seong; Audrey Rakian; Qing Hao; Fermin O Tio; Ajay K Wakhloo; Baruch B Lieber
Journal:  Stroke       Date:  2009-01-15       Impact factor: 7.914

View more
  13 in total

1.  Flat panel angiography images in the post-operative follow-up of surgically clipped intracranial aneurysms.

Authors:  Caterina Budai; Luigi Cirillo; Francesco Patruno; Massimo Dall'olio; Ciro Princiotta; Marco Leonardi
Journal:  Neuroradiol J       Date:  2014-04-18

2.  Feasibility of intravenous flat panel detector CT angiography for intracranial arterial stenosis.

Authors:  J S Jeon; S H Sheen; G J Hwang; H C Kim; B J Kwon
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-30       Impact factor: 3.825

3.  Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

Authors:  Michael Lettau; Martin Bendszus; Stefan Hähnel
Journal:  Neuroradiology       Date:  2013-02-15       Impact factor: 2.804

4.  Impact of a new metal artefact reduction algorithm in the noninvasive follow-up of intracranial clips, coils, and stents with flat-panel angiographic CTA: initial results.

Authors:  Marios-Nikos Psychogios; Bernhard Scholz; Christopher Rohkohl; Yiannis Kyriakou; Alexander Mohr; Peter Schramm; Dorothee Wachter; Katrin Wasser; Michael Knauth
Journal:  Neuroradiology       Date:  2013-04-16       Impact factor: 2.804

5.  Applicability of tableside flat panel detector CT parenchymal cerebral blood volume measurement in neurovascular interventions: preliminary clinical experience.

Authors:  P Mordasini; M El-Koussy; C Brekenfeld; G Schroth; U Fischer; J Beck; J Gralla
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-29       Impact factor: 3.825

6.  Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents.

Authors:  Marc Saake; Tobias Struffert; Philipp Goelitz; Sabine Ott; Frank Seifert; Oliver Ganslandt; Arnd Doerfler
Journal:  Neuroradiology       Date:  2011-10-04       Impact factor: 2.804

7.  Feasibility of flat panel angiographic CT after intravenous contrast agent application in the postoperative evaluation of patients with clipped aneurysms.

Authors:  M-N Psychogios; D Wachter; A Mohr; P Schramm; A-M Frölich; K Jung; V Rohde; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-18       Impact factor: 3.825

8.  Flat-detector computed tomography evaluation in an experimental animal aneurysm model after endovascular treatment: A pilot study.

Authors:  Sabine Ott; Philipp Gölitz; Edyta Adamek; Kevin Royalty; Arnd Doerfler; Tobias Struffert
Journal:  Interv Neuroradiol       Date:  2015-06-25       Impact factor: 1.610

9.  Use of cone-beam computed tomography angiography in planning for gamma knife radiosurgery for arteriovenous malformations: a case series and early report.

Authors:  Mina G Safain; Jason P Rahal; Ami Raval; Mark J Rivard; John E Mignano; Julian K Wu; Adel M Malek
Journal:  Neurosurgery       Date:  2014-06       Impact factor: 4.654

10.  Angiographic C-arm CT visualization of the Woven EndoBridge cerebral aneurysm embolization device (WEB): first experience in an animal aneurysm model.

Authors:  T Struffert; S Lang; E Adamek; T Engelhorn; C M Strother; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-05-28       Impact factor: 3.649

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.