PURPOSE: Since the introduction of flat panel detector-equipped C-arms, the use of flat panel detector CT (FPCT) in the neuroradiologic angiography suite has become more frequent. This examination implicates its own specific radiation exposure. We used the CT dose index (CTDI) concept and adapted it to the special FPCT geometry to provide a consistent comparison with multisection head CT (cCT).
MATERIALS AND METHODS: Exposure data obtained for routine scanning during a period of 1 year were used to assess a specific dose of a total of 217 rotational scans performed in 105 patients. One hundred seventy-two scans were 3D digital subtraction angiography (DSA) scans. There were 45 scans that were performed to achieve high-quality, soft-tissue resolution. Dose measurements in cylindrical polymethylmethacrylate (PMMA) phantoms were used to determine the CTDI value and to compare it with the reference values for cCT. In addition, the dose-area product (DAP) was registered and correlated with the CTDI and corresponding dose-length product (DLP) values. Exposure data and dose values were compared with cCT.
RESULTS: Mean-weighted CTDI value of 3D-DSA was approximately 9 mGy per scan. High-quality, soft-tissue resolution FPCT scans, comparable with cCT, revealed a mean dose value of 75 mGy (reference value for cCT, CTDI(w) approximately 60 mGy).
CONCLUSION: The high-speed scans used for 3D-DSA revealed a significantly lower CTDI(w) and DLP compared with clinical CT. The high-quality FPCT protocol resulted in a higher dose and should therefore be limited to acute cases, when patient transfer to a CT scanner is considered to be a disadvantage for patient management.

Entities:  

Mesh:

Year:  2008        PMID: 18687748      PMCID: PMC8118925          DOI: 10.3174/ajnr.A1237

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  17 in total

1.  A performance comparison of flat-panel imager-based MV and kV cone-beam CT.

Authors:  B A Groh; J H Siewerdsen; D G Drake; J W Wong; D A Jaffray
Journal:  Med Phys       Date:  2002-06       Impact factor: 4.071

2.  Flat-panel cone-beam computed tomography for image-guided radiation therapy.

Authors:  David A Jaffray; Jeffrey H Siewerdsen; John W Wong; Alvaro A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-08-01       Impact factor: 7.038

3.  Dose and image quality for a cone-beam C-arm CT system.

Authors:  Rebecca Fahrig; Robert Dixon; Thomas Payne; Richard L Morin; Arundhuti Ganguly; Norbert Strobel
Journal:  Med Phys       Date:  2006-12       Impact factor: 4.071

4.  Myelography using flat panel volumetric computed tomography: a comparative study in patients with lumbar spinal stenosis.

Authors:  Tobias Engelhorn; Janine Rennert; Gregor Richter; Tobias Struffert; Oliver Ganslandt; Arnd Doerfler
Journal:  Spine (Phila Pa 1976)       Date:  2007-08-15       Impact factor: 3.468

5.  Novel methods of measuring single scan dose profiles and cumulative dose in CT.

Authors:  K D Nakonechny; B G Fallone; S Rathee
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

6.  A method for describing the doses delivered by transmission x-ray computed tomography.

Authors:  T B Shope; R M Gagne; G C Johnson
Journal:  Med Phys       Date:  1981 Jul-Aug       Impact factor: 4.071

7.  Aneurysmal rupture during embolization with Guglielmi detachable coils: causes, management, and outcome.

Authors:  A Doerfler; I Wanke; T Egelhof; U Dietrich; S Asgari; D Stolke; M Forsting
Journal:  AJNR Am J Neuroradiol       Date:  2001 Nov-Dec       Impact factor: 3.825

8.  Calculation of effective dose.

Authors:  C H McCollough; B A Schueler
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

9.  Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry.

Authors:  Shinichiro Mori; Masahiro Endo; Kanae Nishizawa; Takanori Tsunoo; Takahiko Aoyama; Hideaki Fujiwara; Kenya Murase
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

10.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.

Authors:  M J Daly; J H Siewerdsen; D J Moseley; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

View more
  17 in total

1.  Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

Authors:  M-N Psychogios; P Schramm; J-H Buhk; A Xyda; K Gröschel; K Jung; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

Review 2.  [Flat-detector computed tomography in diagnostic and interventional neuroradiology].

Authors:  T Struffert; A Doerfler
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

3.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

4.  Overlying fluoroscopy and preacquired CT angiography for road-mapping in cerebral angiography.

Authors:  C-J Lin; R Blanc; F Clarençon; M Piotin; L Spelle; J Guillermic; J Moret
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-15       Impact factor: 3.825

5.  C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis.

Authors:  Simon C Leschka; Drazenko Babic; Samer El Shikh; Christine Wossmann; Martin Schumacher; Christian A Taschner
Journal:  Neuroradiology       Date:  2011-04-08       Impact factor: 2.804

6.  Intravenous flat detector CT angiography for non-invasive visualisation of intracranial flow diverter: technical feasibility.

Authors:  Tobias Struffert; Marc Saake; Sabine Ott; Tobias Engelhorn; Philipp Gölitz; Stephan Kloska; Marc Doelken; Arnd Doerfler
Journal:  Eur Radiol       Date:  2011-03-30       Impact factor: 5.315

7.  Angiographic CT with intravenous contrast injection compared with conventional rotational angiography in the diagnostic work-up of cerebral aneurysms.

Authors:  P Gölitz; T Struffert; F Knossalla; M Saake; S Ott; O Ganslandt; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

8.  [The urological Dyna-CT. Urological cross-sectional imaging on a newly developed urological intervention table].

Authors:  M S Michel; M Ritter; S Schönberg; A Häcker; G Weisser
Journal:  Urologe A       Date:  2012-06       Impact factor: 0.639

9.  Brain radiation doses to patients in an interventional neuroradiology laboratory.

Authors:  R M Sanchez; E Vano; J M Fernández; M Moreu; L Lopez-Ibor
Journal:  AJNR Am J Neuroradiol       Date:  2014-03-13       Impact factor: 3.825

10.  Angiographic C-arm CT visualization of the Woven EndoBridge cerebral aneurysm embolization device (WEB): first experience in an animal aneurysm model.

Authors:  T Struffert; S Lang; E Adamek; T Engelhorn; C M Strother; A Doerfler
Journal:  Clin Neuroradiol       Date:  2013-05-28       Impact factor: 3.649

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.