Literature DB >> 18810455

Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms--a comparative study with DSA and TOF-MRA.

Jan-Hendrik Buhk1, Kai Kallenberg, Alexander Mohr, Peter Dechent, Michael Knauth.   

Abstract

Following coil embolization of intracranial aneurysms, many centers perform at least one digital subtraction angiography (DSA) continuing with time-of-flight magnetic resonance angiography (TOF-MRA). Angiographic computed tomography (ACT) provides high-resolution data from a rotational acquisition of a c-arm-mounted flat panel detector. This study evaluates possible advantages of applying ACT in aneurysm follow-up. In 22 patients DSA examinations with a rotational acquisition were performed. Rotational data were processed into an isotropic high-resolution volume. TOF-MRA was performed the day before DSA. Three experienced neuroradiologists performed a rating of the occlusion rate and a subjective method comparison. Weighted kappa statistics were calculated to assess the level of interobserver agreement. Compared to DSA, the diagnostic value of ACT as well as of TOF-MRA was rated to be inferior, although the sensitivity of detecting residual necks was higher with both techniques. Compared to TOF-MRA, ACT achieves favorable ratings only in aneurysms after stent-remodeling. Interobserver agreement was high for all techniques. Ratings of the occlusion rate correlated highly between all observers (r>0.85, p<0.001, respectively). In selected patients ACT can add valuable diagnostic information to DSA. TOF-MRA remains a highly sensitive method for aneurysm follow-up.

Entities:  

Mesh:

Year:  2008        PMID: 18810455     DOI: 10.1007/s00330-008-1171-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  21 in total

1.  [The use of flat-panel detectors for CT imaging].

Authors:  W A Kalender
Journal:  Radiologe       Date:  2003-05       Impact factor: 0.635

2.  Angiographic CT in cerebrovascular stenting.

Authors:  Götz Benndorf; Charles M Strother; Benjamin Claus; Ramin Naeini; Hesham Morsi; Richard Klucznik; Michael E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

3.  MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils.

Authors:  Charles B L M Majoie; Marieke E Sprengers; Willem Jan J van Rooij; Cristina Lavini; Menno Sluzewski; Jeroen C van Rijn; Gerard J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

4.  Intracranial aneurysms: treatment with bare platinum coils--aneurysm packing, complex coils, and angiographic recurrence.

Authors:  Michel Piotin; Laurent Spelle; Charbel Mounayer; Marco T Salles-Rezende; Daniel Giansante-Abud; Ricardo Vanzin-Santos; Jacques Moret
Journal:  Radiology       Date:  2007-02-09       Impact factor: 11.105

5.  Three-dimensional time-of-flight MR angiography for evaluation of intracranial aneurysms after endosaccular packing with Guglielmi detachable coils: comparison with 3D digital subtraction angiography.

Authors:  Mika Okahara; Hiro Kiyosue; Yuzo Hori; Masanori Yamashita; Hirofumi Nagatomi; Hiromu Mori
Journal:  Eur Radiol       Date:  2004-04-21       Impact factor: 5.315

6.  Time-of-flight MR angiography targeted to coiled intracranial aneurysms is more sensitive to residual flow than is digital subtraction angiography.

Authors:  Naoaki Yamada; Katsuhiko Hayashi; Kenichi Murao; Masahiro Higashi; Koji Iihara
Journal:  AJNR Am J Neuroradiol       Date:  2004-08       Impact factor: 3.825

7.  Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.

Authors:  G Richter; T Engelhorn; T Struffert; M Doelken; O Ganslandt; J Hornegger; W A Kalender; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-24       Impact factor: 3.825

8.  Diagnostic accuracy of 3D time-of-flight MR angiography compared with digital subtraction angiography for follow-up of coiled intracranial aneurysms: influence of aneurysm size.

Authors:  H A Deutschmann; M Augustin; J Simbrunner; B Unger; H Schoellnast; G A Fritz; G E Klein
Journal:  AJNR Am J Neuroradiol       Date:  2007-04       Impact factor: 3.825

9.  Angiographic CT with intravenous administration of contrast medium is a noninvasive option for follow-up after intracranial stenting.

Authors:  Jan-Hendrik Buhk; Paul Lingor; Michael Knauth
Journal:  Neuroradiology       Date:  2008-02-02       Impact factor: 2.804

10.  Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT).

Authors:  Adriana Campi; Najib Ramzi; Andrew J Molyneux; Paul E Summers; Richard S C Kerr; Mary Sneade; Julia A Yarnold; Joan Rischmiller; James V Byrne
Journal:  Stroke       Date:  2007-03-29       Impact factor: 7.914

View more
  20 in total

1.  Optimized intravenous Flat Detector CT for non-invasive visualization of intracranial stents: first results.

Authors:  Tobias Struffert; Stephan Kloska; Tobias Engelhorn; Yu Deuerling-Zheng; Sabine Ott; Marc Doelken; Marc Saake; Martin Köhrmann; Arnd Doerfler
Journal:  Eur Radiol       Date:  2010-08-14       Impact factor: 5.315

Review 2.  MRA versus DSA for follow-up of coiled intracranial aneurysms: a meta-analysis.

Authors:  M J van Amerongen; H D Boogaarts; J de Vries; A L M Verbeek; F J A Meijer; M Prokop; R H M A Bartels
Journal:  AJNR Am J Neuroradiol       Date:  2013-09-05       Impact factor: 3.825

Review 3.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology.

Authors:  Mudassar Kamran; Sanjoy Nagaraja; James V Byrne
Journal:  Neuroradiology       Date:  2009-10-27       Impact factor: 2.804

4.  Artifact reduction of different metallic implants in flat detector C-arm CT.

Authors:  S-C Hung; C-C Wu; C-J Lin; W-Y Guo; C-B Luo; F-C Chang; C-Y Chang
Journal:  AJNR Am J Neuroradiol       Date:  2014-01-23       Impact factor: 3.825

5.  A study of the first-generation pipeline embolization device morphology using intraoperative angiographic computed tomography (ACT).

Authors:  Thaweesak Aurboonyawat; Paul J Schmidt; Michel Piotin; Raphael Blanc; Laurant Spelle; Jacques Moret
Journal:  Neuroradiology       Date:  2010-05-18       Impact factor: 2.804

6.  Feasibility of angiographic CT in peri-interventional diagnostic imaging: a comparative study with multidetector CT.

Authors:  M-N Psychogios; J-H Buhk; P Schramm; A Xyda; A Mohr; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-04-01       Impact factor: 3.825

7.  Combining monoenergetic extrapolations from dual-energy CT with iterative reconstructions: reduction of coil and clip artifacts from intracranial aneurysm therapy.

Authors:  Sebastian Winklhofer; Ricarda Hinzpeter; Daniel Stocker; Gerasimos Baltsavias; Lars Michels; Jan-Karl Burkhardt; Luca Regli; Antonios Valavanis; Hatem Alkadhi
Journal:  Neuroradiology       Date:  2018-01-22       Impact factor: 2.804

8.  Metal artifact reduction algorithm for image quality improvement of cone-beam CT images of medium or large cerebral aneurysms treated with stent-assisted coil embolization.

Authors:  Satoshi Murai; Masafumi Hiramatsu; Yuji Takasugi; Yu Takahashi; Naoya Kidani; Shingo Nishihiro; Yukei Shinji; Jun Haruma; Tomohito Hishikawa; Kenji Sugiu; Isao Date
Journal:  Neuroradiology       Date:  2019-11-07       Impact factor: 2.804

9.  Comparison of 3D computer-aided with manual cerebral aneurysm measurements in different imaging modalities.

Authors:  M Groth; N D Forkert; J H Buhk; M Schoenfeld; E Goebell; J Fiehler
Journal:  Neuroradiology       Date:  2012-09-25       Impact factor: 2.804

10.  Optimized angiographic CT using intravenous contrast injection: a noninvasive imaging option for the follow-up of coiled aneurysms?

Authors:  P Gölitz; T Struffert; I Kaschka; K Roessler; F Knossalla; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-17       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.