A performance comparison of flat-panel imager-based MV and kV cone-beam CT.

B A Groh1, J H Siewerdsen, D G Drake, J W Wong, D A Jaffray.   

Abstract

The use of cone-beam computed tomography (CBCT) has been proposed for guiding the delivery of radiation therapy, and investigators have examined the use of both kilovoltage (kV) and megavoltage (MV) x-ray beams in the development of such CBCT systems. In this paper, the inherent contrast and signal-to-noise ratio (SNR) performance for a variety of existing and hypothetical detectors for CBCT are investigated analytically as a function of imaging dose and object size. Theoretical predictions are compared to the results of experimental investigations employing largearea flat-panel imagers (FPIs) at kV and MV energies. Measurements were performed on two different FPI-based CBCT systems: a bench-top prototype incorporating an FPI and kV x-ray source (100 kVp x rays), and a system incorporating an FPI mounted on the gantry of a medical linear accelerator (6 MV x rays). The SNR in volume reconstructions was measured as a function of dose and found to agree reasonably with theoretical predictions. These results confirm the theoretically predicted advantages of employing kV energy x rays in imaging soft-tissue structures found in the human body. While MV CBCT may provide a valuable means of correcting 3D setup errors and may offer an advantage in terms of simplicity of mechanical integration with a linear accelerator (e.g., implementation in place of a portal imager), kV CBCT offers significant performance advantages in terms of image contrast and SNR per unit dose for visualization of soft-tissue structures. The relatively poor SNR performance at MV energies is primarily a result of the low x-ray quantum efficiencies (approximately a few percent or less) that are currently achieved with FPIs at high energies. Furthermore, kV CBCT with an FPI offers the potential of combined volumetric and radiographic/fluoroscopic imaging using the same device.

Entities:  

Mesh:

Year:  2002        PMID: 12094992     DOI: 10.1118/1.1477234

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  37 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

2.  Flat-panel versus 64-channel computed tomography for in vivo quantitative characterization of aortic atherosclerotic plaques.

Authors:  Ibrahim Aboshady; Dianna D Cody; Evan M Johnson; Amir Gahremanpour; Deborah Vela; Kamal G Khalil; Herbert L Dupont; James T Willerson; L Maximilian Buja; Gregory W Gladish
Journal:  Int J Cardiol       Date:  2010-12-24       Impact factor: 4.164

3.  Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.

Authors:  Konstantin Nikolaou; Thomas Flohr; Karl Stierstorfer; Christoph R Becker; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2004-11-20       Impact factor: 5.315

Review 4.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

5.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

6.  Exact reconstruction of volumetric images in reverse helical cone-beam CT.

Authors:  Seungryong Cho; Dan Xia; Charles A Pelizzari; Xiaochuan Pan
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

7.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

Review 8.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

Review 9.  [Application of C-arm computed tomography in cardiology].

Authors:  J Rieber; C Rohkohl; G Lauritsch; H Rittger; O Meissner
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

10.  A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.